If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-M13SKCV-E. We hope that this TOSHIBA RAS-M13SKCV-E user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAS-M13SKCV-E.
Manual abstract: user guide TOSHIBA RAS-M13SKCV-ESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] SVM-07034-2
SERVICE MANUAL
SPLIT TYPE
Indoor Unit
<High Wall, Heat Pump Type>
RAS-M07SKV-E RAS-M10SKV-E RAS-M13SKV-E RAS-M16SKV-E
<High Wall, Cooling Type>
RAS-M10SKCV-E RAS-M13SKCV-E RAS-M16SKCV-E
R410A
Revised May, 2009
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] In that case, set the timer operation again.
NOTE : The Everyday Timer is reset while a command signal can be received from the remote controller even if it stopped due to a power failure.
41
9-4. Remote control and its functions
2 3 4 5 6 7 8 9 18 10 19 11 12 20 13 14 15 16 17 18 19 20 21
1
Infrared signal emitter Start/Stop button Mode select button (MODE) Temperature button (TEMP) Fan speed button (FAN Swing louver button (SWING) Set louver button (FIX) On timer button (ON) Off timer button (OFF) Sleep timer button (SLEEP) Setup button (SET) Clear button (CLR) Memory and Preset button (PRESET) One Touch button (ONE-TOUCH) High power button (Hi-POWER) Economy button (ECO) Quiet button (QUIET) Comfort sleep button (COMFORT SLEEP) Filter reset button (FILTER) Clock Reset button (CLOCK) Check button (CHK)
1
PRESET
FAN
TEMP
13
ONE-TOUCH
5 4 3 18 15 16 12 9 11 20
MODE
14 2 17
SWING FIX Hi-POWER ECO QUIET COMFORT SLEEP
6
7 8 10 21 19
TIMER ON
SLEEP CLR
OFF
SET
CHK
FILTER
CLOCK
9-4-2. ONE-TOUCH Press the "ONE-TOUCH" button for fully automated operation that is customised to the typical consumer preferences in your region of the world. The coutomised settings control temperature air flow strength, air flow direction and other settings to provide you alternate contact with "ONE-TOUCH" OF THE BUTTON. If you prefer other settings you can select from the many other operation functions of your Toshiba unit Press ONE-TOUCH : Start the operaton.
2. AUTOMATIC OPERATION To automatically select cooling, heating, or fan only operation. COOLING / HEATING / FAN ONLY OPERATION To automatically select cooling, heating, or fan only operation. Press HIGH MODE : Select Cool , Heat , or Fan only . 17°C, Heating : Max, 30°C, Fan Only: No temperature indication
- 42 -
4. DRY OPERATION (COOLING ONLY) For dehumidification, a moderate cooling performance is controlled automatically. MODE : Set the desired temperature.
5. Hi-POWER OPERATION To automatically control room temperature and airflow for faster cooling or heating operation (except in DRY and FAN ONLY mode) Press HI-POWER : Start and stop the operation.
6. ECO OPERATION To automatically control room to save energy (except in DRY and FAN ONLY mode) Press ECO : Start and stop the operation. Note: Cooling operation; the set temperature will increase automatically 1 degree/ hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease. TEMPORARY OPERATION In case of the misplaced or discharged remote control · Pressing the RESET button, the unit can start or stop without using the remote control. · Operation mode is set on AUTOMATIC operation, preset temperature is 24°C and fan operation is automatic speed. TIMER OPERATION
Setting the ON Timer Setting the OFF Timer Press Press Press
OFF
1 2 3
Press Press Press
ON
: Set the desired ON timer. : Cancel the timer .
: Set the desired OFF timer. : Set the timer.
SET
SET
CLR
CLR
Everyday timer allows the user to set both the ON & OFF timers and will be activated on a daily basis. Setting Everyday Timer
1
Press
ON
: Set the ON timer.
3
Press
SET
.
2
Press
OFF
: Set the OFF timer.
4
Press button during the ( or ) mark flashing.
SET
· During the every day timer is activation, both arrows ( or ) are indicated. Note: · Keep the remote control in accessible transmission to the indoor unit; otherwise, the time lag of up to 15 minutes will occur. [. . . ] 2) Remove screw of earth lead attached to the end plate of the evaporator. 3) Remove the lead wire cover, and remove connector for the fan motor and connector for the louver motor from the electric parts box assembly. 4) Pull out TC sensor from sensor holder of the evaporator. 5) Pull out TCJ sensor from sensor holder of the evaporator. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-M13SKCV-E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.