Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-M16GKV-E2. We hope that this TOSHIBA RAS-M16GKV-E2 user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAS-M16GKV-E2.
Manual abstract: user guide TOSHIBA RAS-M16GKV-E2SERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] FILE NO. SVM-06036
SUPPLEMENT
SERVICE MANUAL
AIR-CONDITIONER
SPLIT TYPE
RAS-M10GKV-E2, RAS-M13GKV-E2, RAS-M16GKV-E2 RAS-M10GKCV-E2, RAS-M13GKCV-E2, RAS-M16GKCV-E2
(This service manual provide information only on the indoor units. For information on the outdoor unit please refer to the service manual of the outdoor unit. )
R410A
June, 2006
FILE NO. Specifications of Electrical Parts (Indoor unit only) 5. Control Block Diagram (Indoor unit only) 6. [. . . ] Exclusive for HFC refrigerant.
Charge hose Electronic balance for refrigerant charging Torque wrench (nominal diam. 1/2, 5/8) Flare tool (clutch type) Gauge for projection adjustment
Vacuum pump adapter
Gas leakage detector
· Incidentally, the "refrigerant cylinder" comes with the refrigerant designation (R-410A) and protector coating in the U. S's ARI specified rose color (ARI color code: PMS 507). · Also, the "charge port and packing for refrigerant cylinder" require 1/2 UNF 20 threads per inch corresponding to the charge hose's port size.
25
FILE NO. Installation Diagram of Indoor Units
65 mm or more
170
mm
Hook
or m ore
1 Installation
plate
For the rear left and left piping
Wall
Hoo
k
170
mm
or m
ore
Air
filte
r
Insert the cushion between the indoor unit and wall, and tilt the indoor unit for better operation.
Shield pipe
(At
tac h to
the fron t pa nel . )
Do not allow the drain hose to get slack.
5 Sasa-Zeolite
Vitamin C filter
6 Bio-enzyme &
Gingko filter
Cut the piping hole sloped slightly
8 Pan head wood screw
Make sure to run the drain hose sloped downward.
2 Wireless remote
control
4 Remote control holder
Before installing the wireless remote control
· With the remote control cover open, load the batteries supplied correctly, observing their polarity.
The auxiliary piping can be connected the left, rear left, rear right, right, bottom right or bottom left.
2 Wireless remote control Cover
Insulate the refrigerant pipes separately with insulation, not together.
Right
Rear right
Rear left Left Bottom left
Bottom right
3 Batteries
6 mm thick heat resisting polyethylene foam
- 26 -
FILE NO. Accessory and installation parts
Part No. Part name (Q'ty) Part No.
Part name (Q'ty)
1
Installation plate x 1
4
Remote control holder x 1
7
Mounting screw 4 x 25 l x 6
2
Wireless remote control x 1
5
Sasa-Zeolite Vitamin C filter x 1
8
Pan head wood screw 3. 1 x 16 l x 2
3
Battery x 2
6
Bio-enzyme & Gingko filter x 1
9
B Label x 1
B
Others
Name Owner's manual Installation manual
This model is not equipped with an extension drain hose. Option : For the extension drain hose, use an optionally available RB-821SW or commercially available one.
27
FILE NO. Installation Place
· A place which provides the spaces around the indoor unit as shown in the above diagram. · A place where there is no obstacle near the air inlet and outlet. · A place which allows easy installation of the piping to the outdoor unit. · A place which allows the front panel to be opened. · The indoor unit shall be installed as top of the indoor unit comes to at least 2m height. Also it must be avoided to put anything on the top of the indoor unit.
Mounting the Installation Plate
Anchor bolt holes
62 82. 5
Hook
170 85
CAUTION
· Direct sunlight to the indoor unit wireless receiver should be avoided. · The microprocessor in the indoor unit should not be too close to r-f noise sources. (For details, see the owner's manual. )
1
Hook Hook Thread Pipe hole Indoor unit Weight Pipe hole
Installation plate
7 Mounting screw
Fig. 7-2-3
Remote controller
· A place where there are no obstacles such as a curtain that may block the signal from the indoor unit. · Do not install the remote control in a place exposed to direct sunlight or close to a heating source, such as a stove. · Keep the remote control at least 1 m apart from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference. ) · The location of the remote control should be determined as shown below.
(Side view) (Top view)
5
m Indoor unit 5
45°
45°
When the installation plate is directly mounted on the wall
1. Securely fit the installation plate onto the wall by screwing it in the upper and lower parts to hook up the indoor unit. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in the above figure. Install the installation plate horizontally in the wall.
CAUTION
When installing the installation plate with a mounting screw, do not use the anchor bolt hole. [. . . ] 4 Part name Heat exchanger Procedures 1) Remove the front panel, electrical part and the horizontal louver following procedure 3. 2) Remove the pipe holder at the rear side of main unit. 3) Remove the 2 screws on the heat exchanger at the base bearing. 4) Remove the 2 screws on the heat exchanger at the 2 fixed plates (upper and lower) from the back body, and then pull out the upper side of the heat exchanger slowly. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-M16GKV-E2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-M16GKV-E2 will begin.