Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAS-M18GAV-E. We hope that this TOSHIBA RAS-M18GAV-E user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAS-M18GAV-E.
You may also download the following manuals related to this product:
TOSHIBA RAS-M18GAV-E INSTALLATION MANUAL (610 ko)
Manual abstract: user guide TOSHIBA RAS-M18GAV-ESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] A05-009
SERVICE MANUAL
SPLIT TYPE
<Heat Pump Type>
Indoor Unit
<Cooling OnlyType>
Indoor Unit
RAS-B10GKVP-E RAS-M10GKCVP-E RAS-B13GKVP-E RAS-M13GKCVP-E RAS-B16GKVP-E RAS-M16GKCVP-E
Outdoor Unit Outdoor Unit
RAS-M14GAV-E RAS-M18GAV-E
RAS-M14GACV-E RAS-M18GACV-E
R410A
PRINTED IN JAPAN, Nov. , 2005 ToMo
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Installation Location
· A place which provides enough space around the outdoor unit as shown in the diagram. · A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration. · A place where the operation noise and discharged air do not disturb neighbors. · A place which is not exposed to a strong wind. · A place free of combustible gases. · A place which does not block a passageway. · When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. · Piping connections to the outdoor unit should be arranged in the sequence A, then B, starting from the bottom. (For each piping connection, the gas pipe is on the bottom and the liquid pipe on top. ) · When multiple indoor units are to be connected to the outdoor unit, make sure the ends of the pipes and wires from each indoor unit are connected to the outdoor unit correctly. (Problems caused by indoor units being connected to the outdoor unit incorrectly are very common in multiple-unit installations. ) · The length and height differences of the connecting pipes, between the indoor and outdoor units, must be within the ranges indicated below. · Total piping length: Two room (A + B) Multi · This air conditioner accepts a connection piping length of up to 30 m. · There is no need to add refrigerant as long as the length of the connection piping is 20 m or less.
·
·
·
· ·
· You will need to add 20 g of refrigerant per meter of added connection piping for installations requiring connection piping to be between 21 m to 30 m. · Minimum piping length: A or B = 2 m or more · Maximum indoor piping length: A or B = 20 m or less · Maximum piping height difference: A or B = 10 m or less · Maximum piping / height difference between two rooms = 10 m or less If the outdoor unit is to be mounted on a wall, make sure the platform supporting it is sturdy enough. The platform should be designed and manufactured to maintain its strength over a long period of time, and sufficient consideration should be given to ensuring that the outdoor unit will not fall. When the outdoor unit is to be mounted high on a wall, take particular care to ensure that parts do not fall, and that the installer is protected. When doing installation work at ground level, it is usual to make wiring and pipe connections to the indoor units, first, and then to make connections to the outdoor unit. However, if outdoor work is difficult it is possible, instead, to make changes to the procedure. For example, by making adjustments to the wiring and piping lengths on the inside (rather than the outside). A place where the drain water does not cause any problems. The outdoor unit should not be installed with one indoor unit only. Be sure the (outdoor) unit is installed with at least two indoor units.
Installation diagram of outdoor units
(C) 100 mm or more from wall
80 mm or more only when unobstructed to the front and both sides 50 mm or more In principle, from wall leave open (D) As shown in the figure, position power cord and connecting cable downward, and lead out along piping connection port.
200 mm or more
(B)
(A) 250 mm or more from wall
When installing the outdoor unit, leave open in at least two of directions (A), (B), (C) and (D) shown in the right figure. Ensure sufficient space to allow drainage
Power cord Extension drain hose (Option: RB821SW)
10 m or less
Outdoor unitl
Fig. [. . . ] Drill a hole on the side cabinet (R) for fixing the thermostat fixing plate.
2-2
PVC tube Ø9. 1 P-shape clamp
Heating part
Enlarged marked part
Added hole 2-5 5 46 7
Ø5 hole at two positions When drilling a hole on the side cabinet (R), be sure not to damage the cabinet.
2-3
Side cabinet (R)
Appendix-6
Appendix
No. Photo / Explanatory diagram
Side cabinet (L)
Procedure Rework the side cabinet (L) to remove part of it. The area to be removed is indicated by the shaded lines in the left figure. After removing part of the side cabinet (L), deburr the edges of the side cabinet (L).
2-4
Delete
Perform end process and bundling of each cable. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-M18GAV-E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-M18GAV-E will begin.