Detailed instructions for use are in the User's Guide.
[. . . ] A09-011
SERVICE MANUAL
AIR-CONDITIONER
SPLIT TYPE
RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-5M34UAV-E
R410A
PRINTED IN JAPAN, Feb, 2010 ToMo
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Use copper pipe with 0. 8 mm or more thickness. · Flare nut and flare works are also different from those of the conventional refrigerant. Take out the flare nut attached to the main unit of the air conditioner, and use it.
10-4-3. Installation Place
· · · · · · · · A place which provides the spaces around the outdoor unit. A place where the operation noise and discharged air do not disturb your neighbors. A place which is not exposed to a strong wind. A place which does not block a passageway. When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. There must be sufficient spaces for carrying the unit into and out of the site. A place where the drain water does not raise any problem. A place which can bear the weight of the outdoor unit and does not allow an increase in noise level and vibration.
CAUTION
1. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always to a strong wind like a coast or on a high story of a building, secure the normal fan operation using a duct or a wind shield. Especially in windy area, install the unit to prevent the admission of wind.
OK
NO GOOD
Strong wind
Fig. Installation in the following places may result in trouble. · A place where high-frequency waves are likely · A saline-place such as a coast. to be generated as from audio equipment, welders, and medical equipment.
10-4-4. Optional Installation Parts (Local Supply)
Parts name Indoor unit (abbreviation) Refrigerant piping 1 Putty, PVC tapes 07, 10, 13 16, 18 Parts name Liquid side (O. D. ) 6. 35 mm 6. 35 mm Gas side (O. D. ) 9. 52 mm 12. 7 mm 1 ea. Q'ty
1 Refrigerant piping covered with insulating material (Polyetylene form, 6 mm thick). When duct-type or cassette-type unit is to be installed, it shall be covered with thicker insulating material (Polyetylene form, 10 mm thick).
83
10-4-5. Installation
NOTE
For installation, at least 3 dimensions should be kept free from obstacles (walls).
Necessary space for installation
If you need to install the outdoor unit in a location where there are some obstructions or a wall, secure sufficient space as shown in the figure below. The cooling/heating effect may be reduced by 10%.
Upper side view (Unit: mm)
200 or more
150 or more
300 or more
150 or more
1. [. . . ] Indoor Unit
RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E
224 229 239 225 209 210 201 203
220
240 218 216
214, 215 238 234
211 219
221, 222, 223
206
228 202 208 217 245 205 226 204 227 243 237 232 233
212, 213 248
250
The parts in the following parts list are conformed to RoHS. Therefore be sure to use the following parts for repairing and replacing.
Location Part No. 201 202 203 204 205 206 208 209 210 211 212 213 214 215 216 217 218 219 220 221 43005779 43005778 4301V098 43080609 4308S232 43022455 4302C095 4302C076 4302D003 4306A172 4301V103 4301V104 Description Location Part No. 222 223 224 225 226 227 228 229 232 233 234 237 238 239 240 243 245 248 250 43044876 43044875 43049784 43096255 43096257 4301V097 4301V089 43019904 43062276 43062275 43082296 43083071 43003323 43070199 43079239 43066024 43080608 4308S213 4308S217 Description Refrigeration Cycle Ass'y (M16) Refrigeration Cycle Ass'y (M18) Spring Panel, Bush (L) Panel, Bush (R) Guard, Plasma Pure Filter Base Ass'y, Motor Holder, Sensor Connector, Cover Ass'y Lead, Cover Ass'y Plate, Installation Holder, Remote Controller Body Ass'y, Back Hose, Drain Cap, Drain Remote Controller Wireless Plasma Pure Filter Ass'y Owner's Manual (M10, 13, 16, 18PKVP-E) Owner's Manual (CD-ROM)
Panel Ass'y Frame, Ainl Ass'y Fix, Frame Ass'y Filter, Air Wiring Diagram Louver Ass'y Fan Motor Ass'y Motor, Louver (For Panel) Motor, Louver (For Louver) Cord, Motor, Louver Cover Ass'y, Motor (M18) Cover Ass'y, Motor (M10, 13, 16) 43022458 Base, Bearing Ass'y (M18) 43022459 Base, Bearing Ass'y (M10, 13, 16) 43020372 Fan Ass'y, Cross Flow 43039376 Band, Motor, Right 43125171 Bearing Ass'y, Mold 4301V083 Holder, Pipe 43049787 Pipe, Shield 43044870 Refrigeration Cycle Ass'y (M10, 13)
141