Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAV-134TU-1-PE. We hope that this TOSHIBA RAV-134TU-1-PE user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAV-134TU-1-PE.
Manual abstract: user guide TOSHIBA RAV-134TU-1-PESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Outdoor air inlet temperature 35°C DB. Heating Capacity is based on the following temperature conditions: Indoor air inlet temperature 20°C DB. Outdoor air inlet temperature 7°C DB, 6°C WB. [. . . ] SPECIFICATIONS OF ELECTRICAL PARTS
4. 7 RAV-164AH-PE
No 1 2 3 PARTS NAME Compressor Outdoor unit fan motor Running capacitor for outdoor fan motor Magnetic contactor High pressure switch TYPE PG350X3F-4LS SMF-230-39N-2 EEP2G405HQA114 SPECIFICATIONS Output (rated) 1. 5kW, 2 pole, 220/240V, 1 Phase, 50Hz Output (rated) 39W, 6 pole, 230V, 1 Phase, 50Hz AC 400V, 4µF
4 5
FMCa-1S-02 ACB-2TB04W
AC 220-240V, 50Hz Tripping pressure 30kgf/cm2G Resetting pressure 23kgf/cm2G AC 220-240V
6
Solenoid coil for four-way valve Crankcase heater Sensor for defrosting
CHV-AC240V
7 8
AC 240V, 28W Maximum input 15. 5mA T5A Maximum input 15. 5mA NEV AC 240V AC 220-240V, 50Hz °C k -12 67. 5 10 21. 3 °C k -12 67. 5 10 21. 3
9 10
Fuse Sensor for cooling operation in low ambient temperature Solenoid coil for two-way valve Running capacitor for compressor Transformer (Outdoor Unit) Bimetal thermostat
11
12
MT-44MP456W
AC 440V, 45µF
13 14
FT-67 CS-12A
AC 187-264V Tripping temperature: 110°C Resetting temperature: 90°C
16
4. SPECIFICATIONS OF ELECTRICAL PARTS
4. 8 RAV-134A-PE
No 1 2 3 PARTS NAME Compressor Outdoor unit fan motor Running capacitor for outdoor fan motor Magnetic contactor Pressure switch (2-Stage) TYPE PG330X3F-4LS SMF-230-39N-3 EEP2G405HQA114 SPECIFICATIONS Output (rated) 1. 5kW, 2 pole, 220/240V, 1 Phase, 50Hz Output (rated) 39W, 6 pole, 230V, 1 Phase, 50Hz AC 400V, 4µF
4 5
FMCa-1S-02 STB-X602
AC 220-240V, 50Hz Tripping pressure 19kgf/cm2G, 21kgf/cm2G Resetting pressure 13kgf/cm2G, 15kgf/cm2G AC 240V, 28W T5A
6 7 8
Crankcase heater Fuse Running capacitor for compressor MT-44MP456W
AC 440V, 45µF
4. 9
RAV-164A-PE
No 1 2 3 PARTS NAME Compressor Outdoor unit fan motor Running capacitor for outdoor fan motor Magnetic contactor Pressure switch (2-Stage) TYPE PG350X3F-4LS SMF-230-39N-3 EEP2G405HQA114 SPECIFICATIONS Output (rated) 1. 5kW, 2 pole, 220/240V, 1 Phase, 50Hz Output (rated) 39W, 6 pole, 230V, 1 Phase, 50Hz AC 400V, 4µF
4 5
FMCa-1S-02 STB-X603
AC 220-240V, 50Hz Tripping pressure 21kgf/cm2G, 23kgf/cm2G Resetting pressure 15kgf/cm2G, 17kgf/cm2G AC 240V, 28W T5A
6 7 8
Crankcase heater Fuse Running capacitor for compressor MT-44MP456W
AC 440V, 45µF
17
5. REFRIGERANT PIPING DIAGRAMS
5. 1 Indoor Unit RAV-104TUH-1-PE
Cooling Heating Indoor unit Heat exchanger Distributor strainer capillary tube Strainer
TC Sensor Refrigerant pipe (Liquid) ø6. 4mm (1/4") Refrigerant pipe (Gas) ø12. 7mm (1/2")
18
5. REFRIGERANT PIPING DIAGRAMS
5. 1 Indoor Unit RAV-134TUH-1-PE Outdoor Unit RAV-134AH-PE
Cooling Heating Indoor unit Heat exchanger Distributor strainer capillary tube Strainer
TC Sensor Refrigerant pipe (Liquid) ø6. 4mm (1/4") Refrigerant pipe (Gas) ø12. 7mm (1/2")
Packed valve Line pressure Strainer Cooling P1 High pressure Liquid receiver Capillary tube ø2. 6x400Lx1P Dryer Expansion valve 2-way valve Check valve TL sensor Distributor P2 Low pressure
Packed valve
P2
Heating Low pressure High pressure
Capillary tube ø3. 0x600Lx1P
Heat exchanger
TE sensor Check joint P1 Capillary tube ø0. 8x1000Lx1P Strainer Four-way valve
High pressure switch Accumulator Compressor Outdoor unit
INDOOR UNIT Model Capillary Model
OUTDOOR UNIT Main Bypass Capillary Capillary
Cooling Bypass Capillary IDø3x600Lx1P
RAV-134TUH-1-PE IDø2. 4x300Lx2P RAV-134AH-PE IDø2. 6x400Lx1P IDø0. 8x1000Lx1P
19
5. REFRIGERANT PIPING DIAGRAMS
5. 2 Indoor Unit RAV-164TUH-1-PE Outdoor Unit RAV-164AH-PE
Cooling Heating Indoor unit Heat exchanger Distributor strainer capillary tube Strainer
TC Sensor
Refrigerant pipe (Liquid) ø6. 4mm (1/4")
Refrigerant pipe (Gas) ø12. 7mm (1/2")
Packed valve Line pressure Strainer Cooling P1 High pressure Liquid receiver Capillary tube ø2. 6x400Lx1P Dryer Expansion valve 2-way valve Check valve TL sensor Distributor P2 Low pressure
Packed valve
P2
Heating Low pressure High pressure
Capillary tube ø3. 0x600Lx1P
Heat exchanger
TE sensor Check joint P1 Capillary tube ø0. 8x1000Lx1P Strainer Four-way valve
High pressure switch Accumulator Compressor Outdoor unit
INDOOR UNIT Model Capillary Model
OUTDOOR UNIT Main Bypass Capillary Capillary
Cooling Bypass Capillary IDø3x600Lx1P
RAV-164TUH-1-PE IDø2. 2x200Lx2P RAV-164AH-PE IDø2. 6x400Lx1P IDø0. 8x1000Lx1P
20
5. REFRIGERANT PIPING DIAGRAMS
5. 3 Indoor Unit RAV-134TU-1-PE Outdoor Unit RAV-134A-PE
Indoor unit Heat exchanger Strainer
Distributor strainer & capillary tube
TC Sensor Refrigerant pipe (Smaller side) ø6. 4mm (1/4") Refrigerant pipe (Larger side) ø12. 7mm (1/2")
Packed valve
Packed valve
Liquid tank
Capillary tube
Dryer
Heat exchanger Distributor
Strainer
Compressor Pressure switch
Accumulator
Outdoor unit
INDOOR UNIT Model RAV-134TU-1-PE Capillary IDø2. 4x300Lx2P Model RAV-134A-PE
OUTDOOR UNIT Main Capillary IDø2. 6x400Lx1P
Bypass Capillary
21
5. REFRIGERANT PIPING DIAGRAMS
5. 4 Indoor Unit RAV-164TU-1-PE Outdoor Unit RAV-164A-PE
Indoor unit Heat exchanger Strainer
Distributor strainer & capillary tube
TC Sensor Refrigerant pipe (Smaller side) ø6. 4mm (1/4") Refrigerant pipe (Larger side) ø12. 7mm (1/2")
Packed valve
Packed valve
Liquid tank
Capillary tube
Dryer
Heat exchanger Distributor
Strainer
Compressor Pressure switch
Accumulator
Outdoor unit
INDOOR UNIT Model RAV-164TU-1-PE Capillary IDø2. 2x200Lx2P Model RAV-164A-PE
OUTDOOR UNIT Main Capillary IDø2. 6x400Lx1P
Bypass Capillary
22
6. PERFORMANCE CHARACTERISTICS
6. 1 Cooling capacity
Capacity Ratio (%)
(kW) RAV-134AH-PE 2. 88 3. 06 3. 24 3. 42 3. 60 3. 78 3. 96 4. 14 4. 32 RAV-164AH-PE 3. 60 3. 82 4. 05 4. 28 4. 50 4. 73 4. 95 5. 18 5. 40
Ambient Temp. (Wet Bulb) (°C)
6. 2 Heating capacity
(kW) RAV-134AH-PE
Capacity Ratio (%)
RAV-164AH-PE 6. 00 5. 75 5. 50 5. 25 5. 00 4. 75 4. 50 4. 25 4. 00 3. 75 3. 50 3. 25 3. 00 2. 75
5. 04 4. 83 4. 62 4. 41
Ambient Temp. (Wet Bulb) (°C)
4. 20 3. 99 3. 78 3. 57 3. 36 3. 15 2. 94 2. 73 2. 52 2. 31
Room Temp. PERFORMANCE CHARACTERISTICS
6. 3 Cooling capacity RAV-134AH-PE RAV-164AH-PE
Cooling Capacity Ratio Heating Capacity Ratio
Outdoor Unit Height H (m)
Outdoor Unit Height H (m)
H
L
INDOOR UNIT
Piping Length L (m)
Piping Length L (m)
6. 4 Cooling capacity RAV-134A-PE RAV-164A-PE
Cooling Capacity Ratio
Outdoor Unit Height H (m)
H
L
INDOOR UNIT
Piping Length L (m)
24
6. PERFORMANCE CHARACTERISTICS
6. 5 Piping Length/Additional Refrigerant Volume
!!
The amount of refrigerant put into the outdoor unit at the factory is sufficient to fill up to 20m of refrigerant pipework. If the length of the refrigerant pipework is 20m or less, addition of refrigerant at the installation site is unnecessary. [. . . ] 17 18 19 20 20 21 22 23 24 26 27 28 29 30 31
Part No. 43A45001 43155115 43155080 43A41506 43A41507 43146406 43A46013 43193063 43157167 43A60006 43A47041 43A91016 43A91019 43A91017 43A91023
Description Dryer MF Capacitor Compressor MF Capacitor Fan Comp PG330X3F-4LS Comp PG350X3F-4LS Packed Valve (12. 7mm) Packed Valve (6. 35mm) Spring Heater, Crankcase Fuse T5A Capi Form ASM Roof Plate ASM Side Cabinet ASM Air-Out Cabinet Fin-Guard (back)
Model All All All RAV-134A-PE RAV-164A-PE All All All All All All All All All All
28
7. EXPLODED VIEWS AND PARTS LISTS
7. 4 Ceiling Panel
RBC-U134PG(W)-E
10
8
7
5 10 2 9
6
1
7
3 4
Ref No 1 2 3 4 5
Part No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-134TU-1-PE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-134TU-1-PE will begin.