User manual TOSHIBA RAV-183K-PE SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAV-183K-PE. We hope that this TOSHIBA RAV-183K-PE user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAV-183K-PE.


Mode d'emploi TOSHIBA RAV-183K-PE
Download
Manual abstract: user guide TOSHIBA RAV-183K-PESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Ce manuel dcrit la procdure d'installation de l'unit intrieure. Pour installer l'unit extrieure, reportez-vous au Manuel d'installation fourni avec l'unit extrieure. Bitte lesen Sie dieses Handbuch sorgfltig, bevor Sie mit der Installation des Klimagertes beginnen. In diesem Handbuch wird die Installation der Raumeinheit beschrieben. [. . . ] Flaring Insert a flare nut into the pipe, and flare the pipe. As the flaring sizes of R410A differ from those of refrigerant R22, the flare tools newly manufactured for R410A are recommended. However, the conventional tools can be used by adjusting projection margin of the copper pipe. Projection margin in flaring : B (Unit : mm) Rigid (Clutch type) Outer diam. of copper pipe R410A 6. 4 to 15. 9 0 to 0. 5 R410A tool used R22 (Same as left) Conventional tool used R410A 1. 0 to 1. 5 R22 0. 5 to 1. 0 B Imperial (Wing nut type) Outer diam. of copper pipe 6. 4 or 9. 5 12. 7 or 15. 9 R410A 1. 5 to 2. 0 2. 0 to 2. 5 R22 1. 0 to 1. 5 1. 5 to 2. 0 Flaring diam. meter size : A (Unit : mm) A +0 0. 4 Outer diam. of copper pipe R410A 6. 4 9. 5 12. 7 15. 9 9. 1 13. 2 16. 6 19. 7 R22 9. 0 13. 0 16. 2 19. 2 * In case of flaring for R410A with the conventional flare tool, pull it out approx. 0. 5 mm more than that for R22 to adjust to the specified flare size. The copper pipe gauge is useful for adjusting projection margin size. A 3 Toshiba 1074007701(01EN)_P01-10 9 8 7/16/04, 13:30 EN TOSHIBA RAV-SM561KRT-E (EN) 1074007701 6 REFRIGERANT PIPING Tightening connection CAUTION Do not apply excessive torque. Otherwise, the nut may crack depending on the conditions. (Grounding work) Do not connect the earth wire to gas pipe, city water pipe, lightning rod, or the earth wire of telephone. Incomplete grounding causes an electric shock. For electric work, strictly follow the Local Regulation in each country and the Installation Manual, and use an exclusive circuit. Capacity shortage of power circuit or incomplete installation may cause an electric shock or a fire. CAUTION This indoor unit has no power cord. If incorrect/incomplete wiring is carried out, it will cause an electrical fire or smoke. Be sure to install an earth leakage breaker that is not tripped by shock waves. If an earth leakage breaker is not installed, an electric shock may be caused. Be sure to use the cord clamps attached to the product. Do not damage or scratch the conductive core and inner insulator of power and inter-connecting cables when peeling them. Be sure to comply with local regulations on running the wire from outdoor unit to indoor unit (size of wire and wiring method etc. ) Use the power cord and Inter-connecting cable of specified thickness, type, and protective devices required. REQUIREMENT For power supply wiring, strictly conform to the Local Regulation in each country. For wiring of power supply of the outdoor units, follow the Installation Manual of each outdoor unit. [. . . ] No. (* Display may differ depending on the model of indoor unit. ) Every pushing UNIT button, the indoor unit numbers in the group control are successively displayed. Select the indoor unit of which setting is to be changed. 2 At this time, the fan of the selected indoor unit is turned on and LED indicator on the indoor unit will light up and the locations of indoor units, of which setting is to be changed, can be checked. 3-1 3-2 Specify the CODE No. [12] : System address) / ] button. Indoor unit numbers which had been given prior to the setting change will be displayed. CODE No. SET DATA Change the system address from [3] to [2] with the timer time [ / ] button. UNIT No. R. C. No. Push SET button. If the display changes from flashing to being lit, the setting is completed. CODE No. SET DATA 3-3 UNIT No. R. C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-183K-PE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-183K-PE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag