User manual TOSHIBA RAV-363AH8-PE SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAV-363AH8-PE. We hope that this TOSHIBA RAV-363AH8-PE user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAV-363AH8-PE.


Mode d'emploi TOSHIBA RAV-363AH8-PE
Download
Manual abstract: user guide TOSHIBA RAV-363AH8-PESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] EXPLODED VIEWS AND PARTS LISTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SUMMARY · · The units referred to within this manual conform with the protection requirements of Directives 89/336/EEC Electromagnetic Compatibility and 73/23/EEC Low Voltage. Operating conditions of units are as follows: TEMPERATURE OUTDOOR TEMPERATURE ROOM TEMPERATURE -2 TO 43°C (COOL) -10 TO 21°C (HEAT) 18 TO 32°C (COOL) 15 TO 29°C (HEAT) LESS THAN 80% (COOL) ROOM HUMIDITY Note 1: Cooling Capacity is based on the following temperature conditions: Indoor air inlet temperature 27°C DB, 19°C WB. [. . . ] RBC-B460PE(W) Silky mist (Munsell 1Y8. 9/0. 5) 40 1, 430 500 7 Washable RBC-FD202E RBC-BU1E(W) RBC-CA460BE RBC-LK460BE RBC-RK462BE-PE 6, 000 39+63 ZR49K3-TFD 3. 0 High pressure switch, Fuse, Reverse Phase Protector, Crankcase heater, Inner overload relay, Delivery temperature sensor. RBC-B460PE(W) Silky mist (Munsell 1Y8. 9/0. 5) 40 1, 430 500 7 Washable -4- ITEM Cooling capacity Heating capacity Power source kW kW Phase V Hz MODEL RAV-362CH-PE 10. 0 10. 8 3 380-415 50 COOLING HEATING 4. 0 86 6. 7 42 47/43/40 55 R-22 RAV-462CH-PE 12. 5 13. 8 3 380-415 50 COOLING 5. 15 87 8. 5 50 49/45/41 55 R-22 3. 9 50 Capillary tube & Expansion valve ø 19 (ø22) Flare ø 9. 5 Flare 7. 5 50 20 50 ø 20 (ID) RAV-462CH-PE Silky mist 240 1, 630 640 44 Finned tube Multi-blade fan 2, 100 75 Washable RAV-463AH8-PE Bronze white (Munsell 6Y7. 5/1) 1, 240 930 385 109 Finned tube Propeller fan 6, 000 39+63 ZR61K3-TFD 3. 75 High pressure switch, Fuse, Reverse Phase Protector, Crankcase heater, Inner overload relay, Delivery temperature sensor. HEATING 4. 9 88 8. 0 Power consumption Power factor Running current Starting current Operating noise (SPL) Indoor unit (High, Med, Low) Outdoor unit Name of refrigerant Refrigerant Refrigerant control Larger side size Coupler style Smaller side size Interconnection pipe Coupler style Standard length Maximum pipe lengths *1 Charge volume Add. volume (20-50m) kW % A A dB (A) dB (A) kg g/m mm mm m m 4. 2 89 6. 8 3. 4 50 Capillary tube & Expansion valve ø 19 (ø22) Flare ø 9. 5 Flare 7. 5 50 20 50 ø 20 (ID) RAV-362CH-PE Silky mist 240 1, 430 640 39 Finned tube Multi-blade fan 1, 680 75 Washable RAV-363AH8-PE Bronze white (Munsell 6Y7. 5/1) Maximum height difference m If indoor unit higher If outdoor unit higher Condensate drain pipe diameter INDOOR UNIT Model Appearance colour Height Dimensions Width Depth Net weight Heat exchanger type Indoor fan type Air volume Fan motor output Air filter OUTDOOR UNIT Model Appearance colour Height Dimensions Net weight Heat exchanger type Outdoor fan type Air flow volume Fan motor output Compressor Model Output Safety device kW m 3/h W Width Depth mm mm mm kg m 3/h W mm mm mm kg m mm 1, 240 930 385 101 Finned tube Propeller fan 6, 000 39+63 ZR49K3-TFD 3. 0 High pressure switch, Fuse, Reverse Phase Protector, Crankcase heater, Inner overload relay, Delivery temperature sensor. Specifications are subject to change without notice. * Note 1: (ø22) should be used when the length of pipe exceeds 30m. -5- ITEM Cooling capacity Heating capacity kW kW Phase Power source V Hz MODEL RAV-362UH-PE 10. 0 10. 8 3 380-415 50 COOLING HEATING 4. 0 86 6. 7 42 50/45/42 55 R-22 RAV-462UH-PE 12. 5 13. 8 3 380-415 50 COOLING 5. 15 87 8. 5 50 52/47/44 55 R-22 3. 9 50 Capillary tube & Expansion valve ø 19 (ø22) Flare ø 9. 5 Flare 7. 5 50 20 50 ø 32 (OD) RAV-462UH-PE 350 1, 130 740 53 Finned tube Centrifugal fan 1, 860 90 Washable RAV-463AH8-PE Bronze white (Munsell 6Y7. 5/1) 1, 240 930 385 109 Finned tube Propeller fan 6, 000 39+63 ZR61K3-TFD 3. 75 High pressure switch, Fuse, Reverse Phase Protector, Crankcase heater, Inner overload relay, Delivery temperature sensor. RBC-U462PG(W)-PE Silky mist (Munsell 1Y8. 9/0. 5) 28 1, 290 840 10 Washable HEATING 4. 9 88 8. 0 Power consumption Power factor Running current Starting current Operating noise (SPL) Indoor unit Outdoor unit Name of refrigerant Refrigerant Refrigerant control Larger side size Coupler style Smaller side size Interconnection pipe Coupler style Standard length Maximum pipe lengths *1 Charge volume Add. volume (20-50m) kW % A A dB (A) dB (A) kg g/m mm mm m m 4. 2 89 6. 8 3. 4 50 Capillary tube & Expansion valve ø 19 (ø22) Flare ø 9. 5 Flare 7. 5 50 20 50 ø 32 (OD) RAV-362UH-PE 350 1, 130 740 53 Finned tube Centrifugal fan 1, 680 80 Washable RAV-363AH8-PE Bronze white (Munsell 6Y7. 5/1) Maximum height difference m If indoor unit higher If outdoor unit higher Condensate drain pipe diameter INDOOR UNIT Model Appearance colour Height Dimensions Net weight Heat exchanger type Indoor fan type Air volume Fan motor output Air filter OUTDOOR UNIT Model Appearance colour Height Dimensions Net weight Heat exchanger type Outdoor fan type Air flow volume Fan motor output Compressor Model Output Safety device CEILING PANEL Model Appearance colour Height Dimensions Width Depth Net weight Air filter mm mm mm kg kW m 3/h W Width Depth mm mm mm kg m 3/h W Width Depth mm mm mm kg m mm Black (zinc galvanized steel + thermal insulator) 1, 240 930 385 101 Finned tube Propeller fan 6, 000 39+63 ZR49K3-TFD 3. 0 High pressure switch, Fuse, Reverse Phase Protector, Crankcase heater, Inner overload relay, Delivery temperature sensor. RBC-U462PG(W)-PE Silky mist (Munsell 1Y8. 9/0. 5) 28 1, 290 840 10 Washable Specifications are subject to change without notice. * Note 1: (ø22) should be used when the length of pipe exceeds 30m. -6- 3. CONSTRUCTION VIEWS RAV-363AH8-PE RAV-463AH8-PE Knock-out hole (Bottom) (2-30 x 80 long hole for drain disposal) Air inlet Refrigerant piping joint (Larger side ø 19) Refrigerant piping joint connection port (Smaller side ø 9. 5) Air inlet Earth screw (M6) Carrying handle (Both sides) Carrying handle (Front side only) Anchor bolt hole (4 - 12 x 18 long hole) Air outlet Air outlet Terminal cover Blow out guide mounting hole (8-ø3 embossing) Knock-out hole (ø 40) Space required for service (Space for wiring and piping) Outlet Outlet (Space for wiring and piping) When installed with the inlet faced to the wall side When installed with the outlet faced to the wall side -7- 4. WIRING DIAGRAM A B C 1 2 3 Indoor unit Outdoor unit 1 Earth Screw 2 3 TR Earth RED TD RY05 F RY07 Wave Control Circuit BLK TE TL BLU BLK WHI WHI RED BLK BLK B RED WHI RCO1 BLK RED FM WHI 01 BLK 52C 9 10 11 12 GRY A 63H 20SF F 2 L C GRY RED RCO2 WHI RED FM WHI 02 47C S R T 47C 1 3 2 4 6 14 32 CM L1 L2 L3 N * CH 5 13 31 Power supply 380-415V 3N ~ 50Hz 52 C 1. o shows terminal block and figures show terminal numbers. When the phases are not connected correctly, the reverse phase protector operates and the unit will not start. REFRIGERANT PIPING DIAGRAM Indoor unit RAV-362BH-PE RAV-362CH-PE RAV-362UH-PE RAV-462BH-PE RAV-462CH-PE RAV-462UH-PE Indoor unit Outdoor unit RAV-363AH8-PE RAV463AH8-PE Heating Cooling Heat exchanger Distributor strainer capillary tube Strainer TC Sensor Refrigerant pipe (Smaller side) ø9. 5mm (3/8") Refrigerant pipe (Larger side) ø19mm (3/4") Packed valve Line Pressure Strainer P1 P2 Cooling High pressure Low pressure Packed valve P2 Heating Low pressure High pressure Dryer Capillary tube Expansion valve Check valve Heat exchanger TL sensor Distributor TE sensor Strainer Check joint P1 Bypass Capillary tube Accumulator * Four-way valve High pressure switch TD Sensor Compressor Outdoor unit * RAV-363AH8-PE only INDOOR UNIT OUTDOOR UNIT BYPASS CAPILLARY MODEL CAPILLARY MODEL MAIN CAPILLARY RAV-362BH-PE RAV-362CH-PE RAV-362UH-PE RAV-462BH-PE RAV-462CH-PE RAV-462UH-PE IDø 2X400Lx6P IDø 2X300Lx7P IDø 2X300Lx8P IDø 2. 2X200Lx6P IDø 2X200Lx8P IDø 2X300Lx8P RAV-463AH8-PE IDø 3x600Lx1P RAV-363AH8-PE IDø 2. 4x650Lx1P IDø 1. 7x1000Lx1P - 11 - 7. DESCRIPTION OF OUTDOOR UNIT CONTROL CIRCUIT 7. 1 Outdoor unit control circuit diagram + 5v + 5v HP SW EMS SCAN SWRT O/ R5 I/P P SERIAL SWRT O/ P 4-WAY O/P WATCH- SWRT O/ DOG TIMER P KEY SCAN SWRT O/ KEY SCAN SWRT O/ P I/P TD KEY SENSOR SCAN I/P TE SENSOR KEY - 12 EMERGENCY 4-Way CHANGE AC 240V 7. 2 12V power source circuit Outdoor PC board produces full-wave rectification by diode bridge (DB50) followed by the provision of transistor (Q50) produces DC power source at 12V. 7. 3 5V watchdog timer circuit Basically, the same description as the indoor PC board applies, provided, however, that the reset circuit is not added to the outdoor side. Watchdog timer output Reset input TL TE TD 7. 4 Sensor circuit This circuit detects the temperature by dividing voltage with resistance and sensor and bringing the voltage value into CPU, using the characteristics of the sensor that resistance varies with different temperatures. TE is for defrosting, while TL is for low ambient cooling operation. [. . . ] If the length of the pipe exceeds 20m, add the refrigerant R-22. Overcharge or undercharge of refrigerant in the outdoor unit will cause malfunction of the compressor. The prescribed amount of the replenishment of the refrigerant is shown in the table above. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-363AH8-PE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-363AH8-PE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag