User manual TOSHIBA RAV-462B-PE SERVICE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAV-462B-PE. We hope that this TOSHIBA RAV-462B-PE user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAV-462B-PE.


Mode d'emploi TOSHIBA RAV-462B-PE
Download
Manual abstract: user guide TOSHIBA RAV-462B-PESERVICE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATION OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONTROL BLOCK DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Cap tightening torque 6. 4 Valve size 9. 5 12. 7 15. 9 Charge port 14 to 18 N·m (1. 4 to 1. 8 kgf·m) 33 to 42 N·m (3. 3 to 4. 2 kgf·m) 33 to 42 N·m (3. 3 to 4. 2 kgf·m) 20 to 25 N·m (2. 0 to 2. 5 kgf·m) 14 to 18 N·m (1. 4 to 1. 8 kgf·m) 9-8-2. The amount of refrigerant put into the outdoor unit at the factory is sufficient to fill up to 20 m of refrigerant piping work. If the length of the refrigerant piping work is 20 m or less, addition of refrigerant at the installation site is unnecessary. If the length of the piping work exceeds 20 m, extra refrigerant must be added. Refer to the outdoor installation manual for details of the extra amounts. Overcharge or undercharge of refrigerant in the outdoor unit may cause malfunction of the compressor. Add Only R410A Refrigerant to These Units ­ 39 ­ 9-8-3. Provide heat insulation on the refrigerant piping on both the liquid side and gas side separately, and ensure that all joints in the insulation are completely sealed (without gap). Since the temperature of the piping on the gas side increases during heating operations, the heat insulating material used must be able to withstand temperatures of more than 120°C. Use the pipe insulation supplied in the accessory pack to insulate the piping connecting section on the indoor unit side. Packed valve handling precautions · Open the valve stem all the way out; do not try to open it beyond the stopper. 9-9-2 NOTE : Connect the earth line to the metallic part (i mark) located at the side of 3P terminal. Connect the wires between the units correctly. Errors made in the connections can result in the unit malfunctioning. Connect the control wires between the outdoor unit and indoor unit as shown in the figure below: 9-9-4. Wiring Connections Terminal cover Screws Cord clamp Earth terminal 50 40 Earth line Fig. · Wire type : More than 1. 5 mm2 (H07RN-F or 245IEC66) or 1. 3 mm2 (AWG-16) 1. Remove the Terminal cover and the Cord clamp. Insert the connecting cable into the pipe hole on the wall. Insert the connecting cable fully into the terminal block and secure it tightly with the screw. Tightening Torque: 1. 2 N·m (0. 12 kgf·m) 4. Fix the connecting cable by the Cord clamp with two screws. [. . . ] 14) Take off nut fixing the compressor on the bottom plate. (3 pcs. ) 15) Pull the compressor toward you. CAUTION When reconnecting the lead wires to the compressor terminals after replacement of the compressor, be sure to caulk the Faston terminal without loosening. Compressor lead wire Case thermo Remove (Suction pipe) Remove (Discharge pipe) Compressor nut (3 pcs. ) ­ 77 ­ No. Part name Procedure 1) Perform works of items 1 of and . An outdoor unit has two reactors on the partition plate. ) Remarks Reactor Screws Partition plate Reactor Pulse Modulating Valve (PMV) coil 1. Detachment 1) Perform works of items 1 of and . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-462B-PE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-462B-PE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag