OWNERS MANUAL/INSTALLATION MANUAL
SPLIT TYPE
<NEW DIGITAL INVERTER>
OUTDOOR UNIT
RAV-SM561AT-E, RAV-SM801AT-E, RAV-SM1101AT-E, RAV-SM1401AT-E
R410A
PRINTED IN JAPAN, Apr. , 2005 ToMo
CONTENTS
OUTDOOR
INSTALLATION MANUAL RAV-SM561AT-E, RAV-SM801AT-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 RAV-SM1101AT-E, RAV-SM1401AT-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
INDOOR
OWNERS MANUAL
4-Way Air Discharge Cassette Type
RAV-SP1100UT-E, RAV-SM560UT-E, RAV-SM800UT-E, RAV-SM1100UT-E, RAV-SM1400UT-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Concealed Duct Type
RAV-SM561BT-E, RAV-SM801BT-E, RAV-SM1101BT-E, RAV-SM1401BT-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (2) Check that the air outlet or inlet is not blocked. (3) Turn on the main power switch or the circuit breaker for the main power supply to the air conditioner.
WARNING
Cleaning of the air filter and other parts of the air filter involves dangerous work in high places, so be sure to have a service person do it. Do not attempt it yourself.
NOTE
For Air conditioning system which is operated regularly, cleaning and maintenance of the indoor/outdoor units are strongly recommended. As a general rule, if an indoor unit is operated for about 8 hours daily, the indoor/outdoor units will need to be cleaned at least once every 3-MONTH. This cleaning and maintenance shall be carried out by a qualified person. Failure to clean the indoor/outdoor units regularly will result in poor performance, icing, water leaking and even compressor failure.
69
RAV-SM561CT-E, RAV-SM801CT-E, RAV-SM1101CT-E, RAV-SM1401CT-E
AIR CONDITIONER OPERATIONS AND PERFORMANCE
3 minutes protection function
3-minutes protection function prevents the air conditioner from starting for initial 3 minutes after the main power switch/circuit breaker is turned on for re-starting the air conditioner.
Power failure
Power failure during operation will stop the unit completely. · To restart the operation, push the START/STOP button on the remote controller. · Lightning or a wireless car telephone operating nearby may cause the unit to malfunction. Turn off the main power switch or circuit breaker and then turn them on again. Push the START/STOP button on the remote controller to restart.
Heating characteristics Preheating operation
The air conditioner will not deliver warm air immediately after it is turned on. Warm air will start to flow out after approximately 5 minutes when the indoor heat exchanger warmed up.
Warm air control (In heating operation)
When the room temperature reaches the set temperature, the fan speed is automatically reduced to prevent to blow cold draft. At this time, the outdoor unit will stop.
Defrosting operation
If the outdoor unit is frosted during the heating operation, defrosting starts automatically (for approximately 2 to 10 minutes) to maintain the heating capacity. · The fans in both indoor and outdoor units will stop during the defrosting operation. · During the defrosting operation, the defrosted water will be drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, the heat is absorbed from the outside and brought into the room. This way of heating is called heat pump system. When the outside temperature is too low, it is recommended to use another heating apparatus in combination with the air conditioner.
Attention to snowfall and freeze on the outdoor unit
· In snowy areas, the air inlet and air outlet of the outdoor unit are often covered with snow or frozen up. If snow or freeze on the outdoor unit is left as it is, it may cause machine failure or poor warming. · In cold areas, pay attention to the drain hose so that it perfectly drains water without water remaining inside for freeze prevention. If water freezes in the drain hose or inside the outdoor unit, it may cause machine failure or poor warming.
Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions:
Cooling operation Outdoor temperature : 5°C to 43°C (RAV-SM0AT-E) 15 to 43°C (RAV-SPAT-E, RAV-SM1AT-E) : 21°C to 32°C (Dry valve temp. ), 15°C to 24°C (Wet valve temp. )
Room temperature
CAUTION
Heating operation
Room relative humidity less than 80 %. If the air conditioner operates in excess of this figure, the surface of the air conditioner may cause dewing. : 15°C to 15°C (Wet valve temp. ) : 15°C to 28°C (Dry valve temp. )
Outdoor temperature Room temperature
If air conditioner is used outside of the above conditions, safety protection may work.
70
RAV-SM561CT-E, RAV-SM801CT-E, RAV-SM1101CT-E, RAV-SM1401CT-E
RE-INSTALLATION
DANGER
Ask the dealer or an installation professional to re-install the air conditioner to a new place or move it to another place and to observe the following items. If the air conditioner is inappropriate installed by yourself, it may cause electric shock or fire.
Do not install the air conditioner in the following places
· Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set. [. . . ] board.
Short plug position
Set data
Filter sold separately
To incorporate a filter sold separately
When mounting a filter sold separately, be sure to set up the tap exchange according to the type of filter. In this case, also follow to the basic operation procedure (1 2 3 4 5 6 ). · For the item code in Procedure 3, specify [5d]. · For the set data in Procedure 4, select the setup data of filter to be incorporated from the table below.
Set data 0000 0001 0003 0006 Standard filter (At shipment) Zeolite-3G deodorant filter High-efficiency filter (65%) Deodorant filter Ammonium filter
0000
Standard filter (At shipment)
0001
Zeolite-3G deodorant filter
0003
High-efficiency filter (65%)
Deodorant filter Filter sold separately 0006 Ammonium filter
If selecting the set data 0006, do not discard the removed short plug, but ask the users to keep it.
· Short plug position (CN112, CN111, CN110 from the left)
135
RAV-SM561CT-E, RAV-SM801CT-E, RAV-SM1101CT-E, RAV-SM1401CT-E
8 APPLICABLE CONTROLS
Change of lighting time of filter sign
According to the installation condition, the lighting time of the filter sign (Notification of filter cleaning) can be changed. [. . . ]