User manual TOSHIBA RAV-SM802BT-E INSTALLATION MANUAL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAV-SM802BT-E. We hope that this TOSHIBA RAV-SM802BT-E user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RAV-SM802BT-E.
Manual abstract: user guide TOSHIBA RAV-SM802BT-EINSTALLATION MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] AIR CONDITIONER (SPLIT TYPE) CLIMATISEUR (TYPE SPLIT) KLIMAGERT (SPLIT-TYP) CONDIZIONATORE D'ARIA (TIPO SPLIT) AIRE ACONDICIONADO (TIPO SPLIT) AR CONDICIONADO (TIPO SPLIT) AIRCONDITIONER (GESPLITST TYPE) ( SPLIT)
INSTALLATION MANUAL MANUEL DINSTALLATION INSTALLATIONS-HANDBUCH MANUALE DINSTALLAZIONE MANUAL DE INSTALACIN MANUAL DE INSTALAO INSTALLATIEHANDLEIDING
<Concealed Duct Type>/<Type conduits dissimuls> <Lftungskanalmontage in der Zwischendecke>/<Tipo a condotto nascosto> <Modelo con conductos ocultos>/<Tipo conduta embutida> <Type met weggewerkte kanalen>/< >
Heat Pump Model/Modle thermopompe Gerte mit Heizung/Modello con pompa di riscaldamento Modelo con bomba de calor/Modelo de bomba trmica Model met warmtepomp/
Indoor Unit/Unit intrieure Raumeinheit/Unit interna Unidad interior/Unidade interior Binnenunit/ m Outdoor Unit/Unit extrieure Auengert/Unit esterna Unidad exterior/Unidade exterior Buitenunit/ m
RAV-SM562BT-E RAV-SM802BT-E RAV-SM1102BT-E RAV-SM1402BT-E
RAV-SM562AT-E RAV-SM802AT-E RAV-SM1102AT-E RAV-SM1402AT-E
SP562AT-E SP802AT-E SP1102AT-E SP1402AT-E
Please read this Installation Manual carefully before installing the Air Conditioner. This Manual describes the installation method of the indoor unit. For installation of the outdoor unit, follow the Installation Manual attached to the outdoor unit. Veuillez lire attentivement ce Manuel d'installation avant d'installer le climatiseur. [. . . ] Take out the remote controller cord together with the refrigerant pipe or drain pipe. Be sure to set the remote controller cord so that it passes through the upper side of the refrigerant pipe and drain pipe.
For reference
<Square duct> (Procured locally)
Return Air side G-5 mm holes
E
Supply Air side For supply air side G-5 mm holes
For return air side
28 28
C B A
D A
15
18
18
18
15
18
25
28
28
28
25
25
F 25
25
25
K K F 25
25
E
28 28 I E
28 I
28
A
28
18
J
J H
18
25
18
J A
J H
18
25
Model SM562BT Return Air side (Return filter side) SM802BT SM1102, 1402BT SM562BT Supply Air side SM802BT SM1102, 1402BT
A 700 1000 1350 550 850
B -- 700 1050 455 (65 x 7) 715 (65 x 11)
C 400 430 580 65 65 65
D -- -- -- 530 830 1180
E 420 420 420 265 265 265
F 390 390 390 245 245 245
G 4 8 8 20 28 40
H 350 500 675 275 425 600
I 195 195 195
J -- 350 525
K -- -- -- 130 130 130
132. 5 227. 5 132. 5 307. 5 132. 5 552. 5
1200 1105 (65 x 17)
13
5
DRAIN PIPING WORK
Indoor unit Thermal insulator
1. 5m to 2m Support bracket
Piping material
For laying pipes underground, use hard vinyl chloride pipe. VP25 (Inner diamater 32mm)
1/100 or more downward slope Arched shape
Piping and cautions
Set drain side of pipe at downward slope. (1/100 or more) Be sure to apply thermal insulation (foaming polyethylene, 10mm-thickness or more) for pipes passing through the room. Adhere the connecting sections with vinyl chloride agent surely so that no water leakage is caused. Apply adhesive agent without unevenness around the portion approx. 40mm from the end of hard polyvinyl-chloride pipe. Push the vinyl pipe in the drain socket completely up to the end of the socket. Do not apply strength to the connecting part until the adhesive agent has dried and hardened. Support the piping with hanging bracket so that the force is not applied to connection sections of pipe and pipe is not waved.
NO GOOD
Trap
As shown in the figure, set the collective piping such as the ceiling duct so that waste water does not back up from the main pipe.
NOTES :
Do not make slack or trap at halfway across piping. Set pipes so that the end of drain pipe is not dipped in water, and also keep space 50mm or more to the ground. After piping work, check if water drains smoothly. Hole should be made at a slight downward slant to the outdoor side. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe.
50 mm or more
Do not put the drain hose end into water or drainage.
OK
NO GOOD
Fit insulator so that there is no clearance.
Thermal-insulating process
After checking water drain, be sure to apply the thermal-insulating for connecting portion of the pipes. Apply taping so that there is no clearance on the fitting part of thermal-insulator of the main unit with the insulator procured locally.
Hard polyethylene vinyl pipe Thermal insulator (Procured locally) (Procured locally) Fix thermal insulator by taping Thermal insulator (Main unit side)
14
5 DRAIN PIPING WORK
Drain-up
If down-slope cannot be set on a drain pipe, drain-up is possible. Set the height of drain pipe 550mm or less from the bottom face of the indoor unit. Pull out the drain pipe from connecting port of the drain pipe of the indoor unit by 100mm or shorter, and stand up it vertically. After standing up it vertically, arrange immediately so that it is set with down-slope.
Standing-up: 550mm or less
100mm or shorter Indoor unit
Connection of the drain hose
Insert the drain hose completely into the connecting port of the drain pan. Apply thermal insulation surely to the drain hose with socket thermal insulation seal.
VP 30
Less than 20m
As long as possible (Approx. 100mm) VP 30 VP 30 Extended ventilating pipe VP 30 or more Downward grading 1/100 or more
Check of water drain
After drain pipe work, check that water is drained and there is no water leak from pipe connection portion. In this time, also check there is no trouble of motor sound of the drain pump. Be sure also to perform this check when installing the unit in heating time.
After electric piping work
Before installing a panel, infuse water as shown in the following figure. [. . . ] (After pushing TEST button, operation of the remote controller is not accepted for approx. 1 minute. )
UNIT
VENT
1
CODE No.
SET DATA SETTING TEST
UNIT No.
R. C.
No.
( Display changes according to the model No. of indoor unit. )
2 3
In the group control, every pushing button, the indoor unit No. in the group control is displayed in order. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-SM802BT-E
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-SM802BT-E will begin.