User manual TOSHIBA RAV-SP562AT-E DATA BOOK

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RAV-SP562AT-E. We hope that this TOSHIBA RAV-SP562AT-E user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA RAV-SP562AT-E.


Mode d'emploi TOSHIBA RAV-SP562AT-E
Download

You may also download the following manuals related to this product:

   TOSHIBA RAV-SP562AT-E SERVICE MANUAL (5533 ko)
   TOSHIBA RAV-SP562AT-E INSTALLATION MANUAL (211 ko)

Manual abstract: user guide TOSHIBA RAV-SP562AT-EDATA BOOK

Detailed instructions for use are in the User's Guide.

[. . . ] E06-321 Super Digital Inverter Engineering Data Book Super Digital Inverter DATA BOOK 00 Contents 1-1 1. System overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1. Single sprit system line up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Twin sprit system line up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Air throw distance chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sound characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single System Specifications Indoor unit Model Outdoor unit Cooling capacity Heating capacity Power supply Running current Power consumption Power factor Cooling EER (W/W) 3. 55 A (A) (kW) (%) (W/W) 7. 03 - 6. 44 1. 50 97 3. 73 A 3. 38 A 10. 20 - 9. 35 2. 20 98 3. 64 A Shine white Model Panel color Height Main unit Outer dimension Width Depth Height Ceiling panel (Sold separately) Width Depth Mainunit Total weight Ceiling panel (Sold separately) Heat exchanger Fan Fan unit Standard air flow H/M/L Motor Air filter Controller (Sold separately) Gas side Connecting pipe Liquid side Drain port Sound pressure level Sound power level H/M/L H/M/L (mm) (mm) (mm) (dB A) Centrifugal (kg) Finned tube Centrifugal Centrifugal Centrifugal (mm) (mm) (mm) (mm) (mm) (mm) (kg) 210 910 680 21 210 1180 680 25 210 1595 680 33 210 1595 680 33 4. 17 A 3. 21 A Energy efficiency class * Electrical characteristics Energy rating ** Running current Power consumption Power factor Heating COP 4. 48 A 3. 73 A Energy efficiency class * Energy rating ** Main unit Appearance Ceiling panel (Sold separately) (A) (kW) (%) 6. 61 - 6. 06 1. 41 97 RAV(kW) (kW) SP562AT-E 5. 0 5. 6 SP802AT-E 7. 1 8. 0 SP1102AT-E 10. 0 11. 2 SP1402AT-E 12. 5 14. 0 RAVSM562CT-E SM802CT-E SM1102CT-E SM1402CT-E 1 phase 230V (220 - 240V) 50Hz 9. 47 - 8. 93 2. 10 98 11. 24 - 10. 31 18. 09 - 16. 58 2. 40 97 3. 90 98 11. 72 - 10. 74 17. 39 - 15. 94 2. 50 97 3. 75 98 (m3/min) 13. 0/11. 2/10. 0 18. 5/16. 7/14. 6 27. 5/24. 0/21. 2 30. 0/26. 0/23. 1 (W) 30 40 80 80 Attached main unit RBC-AMT31E2, AS21E2, TCB-SC642TLE2, AX21E2 12. 7 6. 4 15. 9 9. 5 VP25 36/33/30 51/48/45 38/36/33 53/51/48 41/38/35 56/53/50 43/40/37 58/55/52 15. 9 9. 5 15. 9 9. 5 . (dB. A) 2-28 * : IEC standard, ** : AS standard 2-3-2. Twin System Specifications Type Indoor unit 1 Model Indoor unit 2 Outdoor unit Cooling capacity Heating capacity RAVRAV(kW) (kW) SM562CT-E SP1102AT-E 10. 0 11. 2 Indoor unit Power supply Running current (A) 1 phase 230V (220 11. 24 10. 31 2. 40 97 4. 17 A SM802CT-E SP1402AT-E 12. 3 14. 0 RAVSM562CT-E Under Ceiling SM802CT-E _ 240V) 50Hz 18. 09 16. 58 3. 90 98 3. 21 A 17. 39 15. 94 3. 75 98 3. 79 A Centrifugal 18. 5/16. 7/14. 6 40 38/36/33 53/51/48 _ _ Power consumption (kW) Cooling Powerfactor EER Electrical characteristics (%) (W/W) Energy efficiency class * Running current (A) _ 11. 95 10. 95 2. 55 97 4. 39 A Centrifugal _ Power consumption (kW) Heating Powerfactor COP (%) (W/W) Energy efficiency class * Fan Fan unit Standard air flow H/M/L Motor Sound pressure level Sound power level H/M/L H/M/L (m3/min) (W) (dB. A) (dB. A) Outdoor unit Power supply Standard length Min. total length Over 30m Height difference Fan Fan unit Standard air flow high Motor Main Gas side Connecting pipe Liquid side Sub Sound pressure level Sound power level Cooling/Heating Cooling/Heating (mm) (dB. A) (dB. A) Sub Main (mm) (mm) (m3/min) (W) (mm) Outdoor lower Outdoor high (m) (m) (m) (m) (m) 13. 0/11. 2/10. 0 30 36/33/30 51/48/45 1 phase 230V (220 7. 5 5. 0 50 _ 240V) 50Hz (Power exclusive to outdoor is required. ) 7. 5 5. 0 50 40g/m (31m to 50m) 30 30 Propeller fan 125 63 + 63 15. 9 12. 7 9. 5 6. 4 49/51 66/68 30 30 125 63 + 63 15. 9 15. 9 9. 5 9. 5 53/54 70/71 * : IEC standard, ** : AS standard 2-29 2-3-3. Dimension RAV-SM562CT-E, RAV-SM802CT-E, RAV-SM1102CT-E, RAV-SM1402CT-E Upper pipe draw-out port (Knockout hole) Power supply cable take-in port (Knockout) 128 84 210 216 167 Pipe draw-out port (Knockout hole) Drain port VP20 (Inner dia. O 26, hose attached) / Remote controller cable take- in port (Knockout hole) 170 50 110 76 105 (Hanging position) 130 53 70 320 200 (Liquid pipe) 680 Left drain size Refrigerant pipe (Liquid side O C) / B (Hanging position) Refrigerant pipe (Gas side O D) / Hanging bolt Ceiling surface Unit 75 146 Drain pipe connecting port 97 Remote controller cable take- in port 347 262 Power supply cable take-in port (Knockout hole) Remote controller cable take- in port (Knockout hole) 84 Within 50 216 (Gas pipe) 41 90 32 114 92 135 145 32 A Outside air take-in port (Duct sold separately)(Knockout hole O 92) / Pipe hole on wall (O 100 hole) / Drain left pipe draw-out port (Knockout hole) Model name Wireless sensor mounting section A 910 1180 B 855 1125 1540 C D SM562CT SM802CT O 6. 4 / O 9. 5 / O12. 7 / O15. 9 / SM1102CT, SM1402CT 1595 250 or more 250 or more 2-30 500 or more 171 2-3-4. Wiring Diagram RAV-SM562CT-E, RAV-SM802CT-E, RAV-SM1102CT-E, RAV-SM1402CT-E TA 12 12 CN104 (YEL) TCJ 12 12 CN102 (RED) TC 12 12 CN101 (BLK) (EXCT) 123 CN80 (GRN) 12 CN73 (RED) 12 CN70 (WHI) Connection interface (option) CN50 (WHI) CN51 (RED) FS CN34 (RED) 33 22 11 MCC-1402 Control P. C. Board for Indoor Unit DC20V DC15V DC12V DC7V 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 P. C. 3 Board 2 1 1 2 CN40 1 2 (BLU) U3 U4 Terminal for central remote controller CN33 (WHI) LM 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 6 5 4 CN60 3 (WHI) 2 1 2 CN32 1 (WHI) 6 5 4 CN61 3 (YEL) 2 1 Power supply circuit Fuse F302 T3. 15A 250V~ Motor drive circuit + ­ (FAN DRIVE) CN333 (WHI) FM 5 4 3 2 1 5 4 3 2 1 BLK WHI 2 2 CN001 1 1 (WHI) CN334 (WHI) 1 2 3 4 5 1 2 3 4 5 RY 302 RY 303 ~ ~ 3 2 CN309 (YEL) 1 33 22 BLK 11 P301 BLK 1 2 CN66 (WHI) CN41 (BLU) BLK Adapter for Wireless Remote Controller BLK Fuse F301 250V~ T6. 3A B A WHI B A Wired Remote Controller CN68 1 2 3 (BLU) 1 2 3 123 CN304 (GRY) CN67 1 2 3 4 5 (BLK) 1 2 3 4 5 RED WHI BLK Capacitor DP RED WHI Closed-end connector 123 123 123 NOTE FM TA TC TCJ LM DP FS RY302 : Fan motor : Indoor temp. sensor : Louver motor : Drain pump motor : Float switch : Drain control relay Indoor unit earth screw Reactor Color Identification BLK BLU RED GRY PNK GRN WHI BRN ORN YEL : : : : : : : : : : BLACK BLUE RED GRAY PINK GREEN WHITE BROWN ORANGE YELLOW 123 Outdoor unit earth screw Serial signal Single phase 220V, 50Hz LN 2-31 2-3-5. Refrigerant Cycle Diagram RAV-SM562CT-E / RAV-SP562*AT-E Indoor unit TCJ sensor Air heat exchanger TC sensor Outer diameter of refrigerant pipe Gas side OA / 12. 7mm Liquid side OB / 6. 4mm * The refrigerating cycle of the indoor units differs according to the models to be combined. For the refrigerating cycles of the other indoor units, refer to the corresponding Service Manuals described in the list on the cover. Refrigerant pipe at gas side Outer dia. O A / Refrigerant pipe at liquid side Outer dia. O A / Strainer TO sensor Outdoor unit Packed valve Outer dia. O B / Modulating (PMV) (SKV-18D26) Ps TS sensor TD sensor Strainer 4-way valve (STF-0213Z) Muffler O 25 / O 25 / TE sensor Heat exchangerO 8 / 1 row 30 stages FP1. 3 flat fin Accumulator (1500cc) x L210 xL160 Capillary O 3xO 2x // L530 Rotary compressor (DA220A2F-20L) R410A 1. 5 kg Cooling Heating Pressure (MPa) Pd Standard Cooling Overload Low load Standard Heating Overload Low load 2. 71 3. 48 1. 92 2. 22 3. 47 1. 79 Ps 1. 03 1. 16 0. 74 0. 72 1. 16 0. 25 Discharge (TD) 75 81 34 62 81 71 Pipe surface temperature (oC) Suction (TS) 15 20 5 6 20 -16 Indoor heat exchanger (TC) 10 16 2 38 55 30 Indoor/Outdoor temp. Compressor conditions revolutions per Indoor Outdoor heat second (rps) (DB/WB) (oC) fan exchanger (TE) 38 51 11 2 15 -18 * 43 44 24 41 41 70 HIGH HIGH LOW HIGH LOW HIGH Indoor 27/19 32/24 18/15. 5 20/30/15/- Outdoor 35/43/- 5/7/6 24/18 -15/(70%) * 4 poles are provided to this compressor. The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor. 2-32 RAV-SM802CT-E / RAV-SP802AT-E Indoor unit TCJ sensor Air heat exchanger TC sensor Outer diameter of refrigerant pipe Gas side OA / 15. 9mm Liquid side OB / 9. 5mm * The refrigerating cycle of the indoor units differs according to the models to be combined. For the refrigerating cycles of the other indoor units, refer to the corresponding Service Manuals described in the list on the cover. Refrigerant pipe at gas side Outer dia. O A / Refrigerant pipe at liquid side Outer dia. O A / Strainer TO sensor Outdoor unit Packed valve Outer dia. O B / Modulating (PMV) (SKV-18D26) Ps TS sensor TD sensor Strainer 4-way valve (STF-0213Z) Muffler O 25 / O 25 / TE sensor Heat exchanger O 8 / 1 row 30 stages FP1. 3 flat fin Accumulator (1500cc) x L210 x L160 Capillary O 3x O2x / / L530 Rotary compressor (DA220A2F-20L) R410A 2. 1 kg Cooling Heating Pressure (MPa) Pd Standard Cooling Overload Low load Standard Heating Overload Low load 2. 72 3. 57 1. 89 2. 58 3. 49 2. 30 Ps 0. 93 1. 10 0. 74 0. 68 1. 22 0. 25 Discharge (TD) 74 80 34 72 79 91 Pipe surface temperature (oC) Suction (TS) 12 21 7 4 19 - 17 Indoor heat exchanger (TC) 11 17 2 41 55 37 Indoor/Outdoor temp. [. . . ] (dia=100mm) *Not valid in combination with TCB-FF101URE2 and TCB-SP1601UE For fresh air intake and installing high efficiency filter or super long filter *Not valid in combination with TCB-SP1601UE For easy fresh air intake by using the knockout hole of indoor unit. (dia=100mm) *Not valid in combination with TCB-GB1601UE2 Height = 500mm *Not valid in combination with TCB-GB1601UE2 and TCB-GFC1601UE2 Air direction charge by cutting off air discharge port (3pcs) *Not valid in combination with TCB-LF1601UE2, TCB-UFM1601UE, TCB-UFH1601UE Use with TCB-GFC1601UE2 High Efficiency Filter 65 TCB-UFM1601UE Use with TCB-GFC1601UE2 High Efficiency Filter 90 TCB-UFH1601UE Use with TCB-GFC1601UE2 Fresh air inlet Box TCB-GB1601UE2 Use with TCB-GFC1601UE2 Frech air and Filter Chamber TCB-GFC1601UE2 Auxiliary fresh air Flange TCB-FF101URE2 Spacer for height adjustment TCB-SP1601UE Air discharge direction kit TCB-BC1601UE 5-2 Ceiling Type Elbow piping kit Optional accessories TCB-KP12CE2 TCB-KP22CE2 Drain pump kit TCB-DP22CE2 Parts Name Model name Applied Model MMC-AP0151/0181H Notes Stand-up 600 or less (from bottom face of ceiling) Remarks Use with TCB-KP12CE Use with TCB-KP22CE Drain Pump Kit TCB-DP22CE2 MMC-AP0241H/0271/0361H/0481H TCB-KP12CE2 2HP 3-5HP Elbow Piping Kit TCB-KP22CE2 Needed when Drain Pump Kit is used Duct Type Model name High Efficiency Filter 65 TCB-UFM11BFCE TCB-UFM21BFCE TCB-UFM21BE TCB-UFM31BE TCB-UFM41BE High Efficiency Filter 90 TCB-UFH51BFCE TCB-UFH61BFCE TCB-UFH61BE TCB-UFH71BE TCB-UFH81BE Remarks For rear suction ( 2P for 3HP ) For rear suction ( 2P for 4-5HP ) For Underside suction ( for 2HP ) For Underside suction ( for 3HP ) For Underside suction ( for 4-5HP ) For rear suction ( 2P for 3HP ) For rear suction ( 2P for 4-5HP ) For Underside suction ( for 2HP ) For Underside suction ( for 3HP ) For Underside suction ( for 4-5HP ) 5-3 5-2. Drain up kit Elbow Piping Kit Drain Pump Kit 600 mm * A high-lift drain kit is available as an option (600mm) model name Drain Pump Kit Elbow Piping Kit Necessary when Drain Pump kit is used. TCB-KP12CE2 Note RAVSM56*CT-E SM80*CT-E SM110*CT-E SM140*CT-E TCB-DP22CE2 TCB-KP22CE2 Dimension Drain pump kit (TCB-DP22CE2) Drain pipe connecying port (VP25A) Water extractionpipe (rubber plug) Suction pipe Elbow piping kit (TCB-KP12CE2, TCB-KP22CE2) (Liquid side) (Gas side) OB Flare connection / OA Flare connection / model TCB-KP12CE2 TCB-KP22CE2 A 6. 4 9. 5 B 12. 7 15. 9 5-4 5-3. Twin kit COMPONENT The following parts are supplied as accessories of the branch pipes. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAV-SP562AT-E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAV-SP562AT-E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag