User manual TOSHIBA RBC-FDP2-F-PE INSTALLATION MANUAL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA RBC-FDP2-F-PE. We hope that this TOSHIBA RBC-FDP2-F-PE user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA RBC-FDP2-F-PE.
Manual abstract: user guide TOSHIBA RBC-FDP2-F-PEINSTALLATION MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Additional preset modes are available using SW1 and SW2 to operate the system in preset Heat, Cool and Auto modes*. Fault Monitoring
20. 00
72. 00
The FDP can be mounted horizontally or vertically.
Ø 9. 00
FDP2-F Fault Interface
TCC-NET D-BUS RELAY
8 Units max
Ø 9. 00
A
B
D1
ON
D2 SW7
C
R1
R2
26. 00
ON
SW1
RealTime Control Systems Ltd FDP2 Model 9410-2-A6
Basic Cable Installation
Cabling should be a minimum 0. 75mm2 throughout. [. . . ] In standard configuration up to 16 FDP2 devices can be connected together. Each FDP2 is assigned a D-Bus address using the configuration switches SW4 to SW7. Unit addresses are shown below.
ADDRESS 0 ADDRESS 4 ADDRESS 8 ADDRESS 12
FDP2 Group Control
Group control allows up to 16 FDP2s to be connected on a D-Bus local network. Each FDP2 reports faults for the locally attached units. The FDP2 with address 0 is a MASTER and determines the settings for all systems connected to FDP2s addressed as slaves. The operating mode of the master is determined by SW1, SW2 as shown in the Standard Operation configuration instructions overleaf. LOCAL CONTROL With SW1 OFF and SW2 OFF the MASTER FDP2 system operates under the control of the attached remote controller. SLAVE FDP2 devices will duplicate these settings to allow large groups to be controlled from one remote controller. Remote controllers on the slave FDP2s are locked and can be omitted if desired.
FDP2 Duty/Standby Operation
Duty/Standby will alternately run two systems on 24 hour alternating run/standby. If a fault occurs on either system then both systems are switched on until the fault is cleared.
SW3 ON for Duty/standby
Duty/Standby is achieved using two FDP2 devices, one with Address 0 and one with Address 1 with a D-BUS connection between the two. [. . . ] The FDP2 interfaces can also be customised for specific operating requirements. Contact Toshiba for details.
D1 D2 C
D1 D2 C
18
8 Units max
Functional Specification
SPECIFICATION Use solid or stranded 24awg shielded or unshielded twisted pair to Cat3, Cat4 or Cat5 specification. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RBC-FDP2-F-PE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RBC-FDP2-F-PE will begin.