Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA SATELLITE L870-18X. We hope that this TOSHIBA SATELLITE L870-18X user guide will be useful to you.
Lastmanuals help download the user guide TOSHIBA SATELLITE L870-18X.
Manual abstract: user guide TOSHIBA SATELLITE L870-18X
Detailed instructions for use are in the User's Guide.
[. . . ] 8 4 Trial Operation Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Precautions for Safety
· Read this "Precautions for Safety" carefully before installation. · The precautions described below include important items regarding safety. · After the installation work, perform a trial operation to check for any problem. [. . . ] Ask the customer to keep this Installation Manual together with the Owner's Manual.
WARNING
· Ask an authorized dealer or qualified installation professional to install or reinstall the relay interface. Improper installation may result in electric shock or fire. · Perform installation work properly according to this Installation Manual. Improper installation may result in electric shock or fire. Any modification may cause a malfunction, resulting in overheating or fire.
CAUTION
· Perform wiring correctly in accordance with the specified current capacity. Failure to do so may result in short-circuiting, overheating, or fire. · Connect the specified cables for the terminals securely to prevent external forces from affecting them. Failure to do so may result in disconnection, overheating, or fire.
1
Introduction
nApplications/Functions/Specifications Applications/Functions/Specifications · Applications
The Energy Monitoring Relay Interface is used to measure and distribute the power of the air conditioner.
· Functions
The interface calculates output power pulses with connected power meters, and then sends the calculation result to the Intelligent Server.
· Specifications
Power supply Power consumption Operating temperature/ humidity Storage temperature Chassis material Dimensions Mass 220 - 240 V, AC 50/60 Hz 2. 8 W 0 to 40°C, 10 to 90% RH -20 to +60°C Galvanized sheet metal 0. 8t 66(H) x 193(W) x 246(D) mm 1. 65 kg Power meter input Input type Input point Input registance Input "ON" current Input pulse condition photo-coupler insulation 8 points 9 k ohm 1 mA 50 m - 1000 m sec
External View
234
18
Grommet for power input
103. 5
18
Grommet for power meter
92. 5 (193)
Grommet for RS-485
53. 5 64. 5
220
18
18
246
2
63. 6
Before Installation
Check the following package contents.
No. 1 2 3 4 Item ENERGY MONITORING RELAY INTERFACE Installation Manual Screw Pin terminal Quantity 1 1 4 2 Remarks
M4 x 12mm tapping screws
Use the following wiring materials to connect signal lines. 1 Signal line For RS-485 Type Wire size Length Type Wire size Length Description 2-core shield wire 1. 25 mm2, 500m max. CAUTION: The SW1 setting is read when the power is turned on. Push the reset switch after changing the address.
NL
DI 1 DI 2 DI 3 DI 4 DI 5 DI 6 DI 7 DI 8
Power meter 1 Power meter 2 Power meter 3 Power meter 4 Power meter 5 Power meter 6 Power meter 7 Power meter 8
ENERGY MONITORING INTERFACE (SATELLITE L870-18X)
CAUTION: RS-485 signals A and B have polarity. Be careful when connecting the RS-485 wire. CAUTION: No terminator resistor setting switch is provided on the Energy Monitoring Relay Interface. Set the RS-485 terminator resistor on the TCS-NET Relay Interface.
7
RS-485
AB
3
SW4
Setting
SW3
ON
LED2
LED3
LED4
SW7
DI2
1234
LED5
DI1
SW1
SW2
SW1
SW2 SW3 SW4 SW7 LED1 LED2 LED3 LED4 LED5
Address set switch 1-4 Address 0, 5 - F Not used Operating mode set switch (0 usually) Test switch (all OFF usually) Test switch Reset switch Power indicator RS-485 communication status indicator Not used Test indicator Test indicator
N
LED1
L
RS-485
The following settings are necessary to use Energy Monitoring Relay Interfaces. · SW1 Address set switch When two or more Energy Monitoring Relay Interfaces are used, set a different address for each unit to avoid address duplication. n)
AB
DI8
DI7
DI6
DI5
DI4
DI3
CAUTION
· Set relay interface addresses according to the air conditioner address table. · When the SW1 setting has been changed, push reset switch SW7. · You can set the Energy Monitoring Relay Interface address independently from the TCSNET Relay Interface address or the Digital Input/Output Relay Interface address. · SW2 Operation mode set switch · SW3 Test switch · SW4 Test switch These switches are not used during normal operation. [. . . ] Set zero (0) or "all OFF".
· SW7 Reset switch When performing a address setting with SW1, push this reset switch after the address setting to read the set value.
8
4
Trial Operation Check
Before starting trial operation
Turn on the power of the Energy Monitoring Relay Interface after all wire connections and settings are completed. Turn on power of the air conditioning control system.
Trial operation
· Confirming connection to power meters In the test mode, when the external inputs connected to the input terminals DI-1 to DI-8 are ON, the respective LEDs will goes on so you can confirm the connection. Confirming procedure: Set the operation mode switch SW2 to "3", and push the reset switch SW7 to enter the test mode. Unless SW4 is pushed, respective input status of DI-1 to DI-4 is indicated by LED2 to LED5. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA SATELLITE L870-18X
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA SATELLITE L870-18X will begin.