User manual TOSHIBA T1-16S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA T1-16S. We hope that this TOSHIBA T1-16S user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA T1-16S.


Mode d'emploi TOSHIBA T1-16S
Download
Manual abstract: user guide TOSHIBA T1-16S

Detailed instructions for use are in the User's Guide.

[. . . ] 6F3B0253 UM-TS01-E031 PROGRAMMABLE CONTROLLER PROSEC T1- 16S USER'S MANUAL - Basic Hardware and Function - TOSHIBA CORPORATION 6F3B0253 Important Information Misuse of this equipment can result in property damage or human injury. Because controlled system applications vary widely, you should satisfy yourself as to the acceptability of this equipment for your intended purpose. In no event will Toshiba Corporation be responsible or liable for either indirect or consequential damage or injury that may result from the use of this equipment. No patent liability is assumed by Toshiba Corporation with respect to use of information, illustrations, circuits, equipment or examples of application in this publication. [. . . ] Refer to Note of Shift register FUN 074. · Multiple counter instructions (CNT) with 132 T1-16S User's Manual 6F3B0253 7. Instructions MCS MCR Expression Input [ MCS ] [ MCR ] Master control set / reset Function When the MCS input is ON, ordinary operation is performed. When the MCS input is OFF, the state of left power rail between MCS and MCR is turned OFF. Execution condition MCS input OFF ON Operation Sets OFF the left power rail until MCR Ordinary operation Output - - Operand No operand is required. Example When X000 is OFF, Y021 and Y022 are turned OFF regardless of the states of X001 and X002. Equivalent circuit X000 Note X001 Y021 · MCS and MCR must be used as a pair. · Nesting is not allowed. X002 Y022 Basic Hardware and Function 133 6F3B0253 7. Instructions JCS JCR Expression Input [ JCS ] [ JCR ] Jump control set / reset Function When the JCS input is ON, instructions between JCS and JCR are skipped (not executed). When the JCS input is OFF, ordinary operation is performed. Execution condition JCS input OFF ON Operation Ordinary operation Skips until JCR Output Operand No operand is required. Example When X000 is ON, the rung 2 circuit is skipped, therefore Y021 is not changed its state regardless of the X001 state. When X000 is OFF, Y021 is controlled by the X001 state. Note · JCS and JCR must be used as a pair. · Nesting is not allowed. 134 T1-16S User's Manual 6F3B0253 7. Instructions END Expression [ END ] End Function Indicates the end of main program or sub-program. Instructions after the END instruction are not executed. At least one END instruction is necessary in a program. Execution condition Input Operation Output Operand No operand is required. Example Note · For debugging purpose, 2 or more END instructions can be written in a program. · Instructions after END instruction are not executed. Those steps are, however, counted as used steps. Basic Hardware and Function 135 6F3B0253 7. Instructions FUN 018 Expression Input -[ A MOV B ]- Output MOV Data transfer Function When the input is ON, the data of A is stored in B. Execution condition Input OFF ON Operation No execution Execution Output OFF ON Operand Name X A Source B Destination Y Device R S T. XW YW RW SW T C D Constant Index I J K Example 1 (constant to register) When R010 is ON, a constant data (12345) is stored in D0100 and the output is turned ON. Example 2 (register to register) When X005 is ON, the data of SW30 is stored in RW45 and the output is turned ON. If SW30 is 500, the data 500 is stored in RW45. Example 3 (index modification) When R050 is changed from OFF to ON, the data of RW08 is stored in the index register I and the data of D(0000+I) is stored in YW10. If RW08 is 300, the data of D0300 is stored in YW10. 136 T1-16S User's Manual 6F3B0253 7. Instructions FUN 019 Expression Input -[ A+1A MOV B+1B ]- Output DMOV Double-word data transfer Function When the input is ON, the double-word (32-bit) data of A+1A is stored in double-word register B+1B. The data range is -2147483648 to 2147483647. Execution condition Input OFF ON Operation No execution Execution Output OFF ON Operand Name X A Source B Destination Y Device R S T. XW YW RW SW T C D Constant Index I J K Example When R011 is ON, a double-word data of D0101D0100 is stored in RW17RW16 and the output is turned ON. [. . . ] block Special device Meaning and countermeasures A register/device which is not supported by the T1-16S is programmed. The timer or counter register is duplicated in the program. The subroutine number programmed with CALL or SUBR instruction is out of the range. (Error down) 0 to 255 Correct the program. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA T1-16S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA T1-16S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag