User manual TOSHIBA TCB-TC21LE INSTALLATION MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TOSHIBA TCB-TC21LE. We hope that this TOSHIBA TCB-TC21LE user guide will be useful to you.

Lastmanuals help download the user guide TOSHIBA TCB-TC21LE.


Mode d'emploi TOSHIBA TCB-TC21LE
Download
Manual abstract: user guide TOSHIBA TCB-TC21LEINSTALLATION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION MANUAL To Personnel Charged in Installation (Electric) Work and Service Accessory parts Part Name Remote sensor (200mm-cable attached) Small screw M4 x 25 1 Wire joint 2 Cable clamper Installation Manual Q'ty Spacer Part Name Q'ty 2 2 1 1 Remote sensor MODEL : TCB-TC21LE Fix it with the spacer, but not so strongly. If the remote sensor does not fit closely to the wall, adjust it by cutting off the spacer. [. . . ] · Do not install the remote sensor at a place behind something or rear side of something, where air flow is poor in the room. · Do not install the remote controller near the freezing box or refrigerator because water proof or drop-proof is not applied to this remote controller. · Be sure to set the remote sensor vertically on the wall surface, etc. A B W B Remote sensor Remote sensor cable (Procured locally) Connecting Cable from remote sensor body section · Non polarity, 2 core cable is used. . · Use 0. 5mm² to 2 mm² cable. Remote sensor cable Cable from remote sensor body Wire joint, CE-1 (Nichiatsu) Attached wire joint (White, 2 pcs. ) How to install the remote sensor NOTE 1 : Avoid to twist the remote sensor cable with the power supply cable, etc. or to store them in the same metal pipe, otherwise it causes a malfunction. NOTE 2 : Install the remote sensor apart from the generation source of noise. NOTE 3 : When noise is induced to the power source of the indoor unit, some measures such as mounting the noise filter is necessary. · In case of using the remote sensor as a concealed type Rear case Spacer Remote sensor body 1) Peel the sheath of the cable to be connected by approx. 2) Twist two cables and pressure-connect them using a wire joint. 3) When an exclusive pressure-connecting tool is not used or soldering connection is used, apply insulation process with an insulation tape. Requirement for using the remote sensor together with the remote controller · How to install For the above control, install the remote sensor in the following procedure. [. . . ] Using the attached M4 screws (2 pcs. ), fix the rear case of the remote sensor. Before installation, press to open the screw hole with a screwdriver, etc. 85464359427000 (EN)-Q [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA TCB-TC21LE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA TCB-TC21LE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag