[. . . ] INSTALLATION MANUAL
To Personnel Charged in Installation (Electric) Work and Service Accessory parts
Part Name Remote sensor (200mm-cable attached) Small screw M4 x 25 1 Wire joint 2 Cable clamper Installation Manual Q'ty Spacer Part Name Q'ty 2 2 1 1
Remote sensor MODEL : TCB-TC21LE
Fix it with the spacer, but not so strongly. If the remote sensor does not fit closely to the wall, adjust it by cutting off the spacer. [. . . ] · Do not install the remote sensor at a place behind something or rear side of something, where air flow is poor in the room. · Do not install the remote controller near the freezing box or refrigerator because water proof or drop-proof is not applied to this remote controller. · Be sure to set the remote sensor vertically on the wall surface, etc.
A B
W B
Remote sensor
Remote sensor cable (Procured locally)
Connecting Cable from remote sensor body section
· Non polarity, 2 core cable is used. . · Use 0. 5mm² to 2 mm² cable.
Remote sensor cable
Cable from remote sensor body
Wire joint, CE-1 (Nichiatsu)
Attached wire joint (White, 2 pcs. )
How to install the remote sensor
NOTE 1 : Avoid to twist the remote sensor cable with the power supply cable, etc. or to store them in the same metal pipe, otherwise it causes a malfunction. NOTE 2 : Install the remote sensor apart from the generation source of noise. NOTE 3 : When noise is induced to the power source of the indoor unit, some measures such as mounting the noise filter is necessary. · In case of using the remote sensor as a concealed type
Rear case Spacer Remote sensor body
1) Peel the sheath of the cable to be connected by approx. 2) Twist two cables and pressure-connect them using a wire joint. 3) When an exclusive pressure-connecting tool is not used or soldering connection is used, apply insulation process with an insulation tape.
Requirement for using the remote sensor together with the remote controller
· How to install
For the above control, install the remote sensor in the following procedure. [. . . ] Using the attached M4 screws (2 pcs. ), fix the rear case of the remote sensor. Before installation, press to open the screw hole with a screwdriver, etc.
85464359427000 (EN)-Q [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA TCB-TC21LE2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.