If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TRANSCEND TS2GSDOM7H. We hope that this TRANSCEND TS2GSDOM7H user guide will be useful to you.
Lastmanuals help download the user guide TRANSCEND TS2GSDOM7H.
Manual abstract: user guide TRANSCEND TS2GSDOM7HDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] TS128M~8GSDOM7H
Description
Serial-ATA is designed as a successor to the legacy SATA standard. [. . . ] 01 02 03 04 05 06 07 Pin Name GND A+ AGND BB+ GND
7P Horizontal Type SATA Flash Modules
Disk Active Indicator
Write-Protect Disabled
Transcend Information Inc.
6 V0. 1
TS128M~8GSDOM7H
Block Block Diagram
7P Horizontal Type SATA Flash Modules
Data bus Data bus
DC Characteristics
Parameter Supply Voltage High level output voltage Low level output voltage High level input voltage Symbol VCC VOH VOL VIH 2. 4 2. 05 Low level input voltage Pull up resistance
2
Pull down resistance
Transcend Information Inc.
SATA 7 PIN Connector 2 PIN
PATA to SATA Bridge
Control Signal
D0 ~ D7 -CE0, -CE1. . .
Flash Memory D0 D7 -CE0 ~ -CE3 -WE. . . -RE
IDE Flash Disk Controller
Others
D8 ~ D15 5V/3. 3V
Flash Memory D0 D7 -CE0 ~ -CE3 -WE. . . -RE
3. 3V/1. 8V Voltage Regulator
-CE0, -CE1. . .
Flash Memory
Min. 5. 5
Unit V V
Remark
0. 8
V V V Non-schmitt trigger Schmitt trigger
1
VIL
0. 6 1. 25
V V KOhm kOhm
Non-schmitt trigger Schmitt trigger
1
RPU RPD
52. 7 47. 5
141 172
7 V0. 1
TS128M~8GSDOM7H
Command Set
Command 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Check Power Mode Execute Drive Diagnostic Erase Sector Flush Cache Format Track Identify Device Idle Idle Immediate Initialize Drive Parameters NOP Read Buffer Read DMA Read Multiple Read Sector(s) Read Verify Sector(s) Recalibrate Request Sense Security Disable Password Security Erase Prepare Security Erase Unit Security Freeze Lock Security Set Password Security Unlock Seek Set Feature Set Multiple Mode Set Sleep Mode Standby Standby Immediate Code E5 or 98h 90h C0h E7h 50h ECh E3h or 97h E1h or 95h 91h 00h E4h C8h C4h 20h or 21h 40h or 41h 1Xh 03h F6h F3h F4h F5h F1h F2h 7Xh EFh C6h E6h or 99h E2 or 96h E0 or 94h FR Y SC Y Y Y Y Y Y Y Y Y SN Y Y Y Y Y Y CY Y Y Y Y Y Y Y DH Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y LBA Y Y Y Y Y
7P Horizontal Type SATA Flash Modules
Status Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support Support
Note
Transcend Information Inc.
V0. 1
TS128M~8GSDOM7H
30 31 32 33 34 35 36 37 38 Translate Sector Wear Level Write Buffer Write DMA Write Multiple Write Multiple w/o Erase Write Sector(s) Write Sector(s) w/o Erase Write Verify 87h F5h E8h CAh C5h CDh 30h or 31h 38h 3Ch Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y
7P Horizontal Type SATA Flash Modules
Support Support Support Support Support Support Support Support Support
Definitions FR = Features Register SC =Sector Count register (00H to FFH, 00H means 256 sectors) SN = Sector Number register CY = Cylinder Low/High register DH = Head No. (0 to 15) of Drive/Head register LBA = Logic Block Address Mode Support = Not used for the command Y = Used for the command
Transcend Information Inc.
V0. 1
TS128M~8GSDOM7H
SMART Command Set
SMART Command Set SMART Feature Register Values D0h D1h D2h D3h D4h Read Data Read Attribute Threshold Enable/Disable Autosave Save Attribute Values Execute OFF-LINE Immediate D5h D6h D8h D9h DAh Read Log Write Log
7P Horizontal Type SATA Flash Modules
Enable SMART Operations Disable SMART Operations Return Status
1. If reserved size is below the Threshold, the status can be read from Cylinder register by Return Status command (DAh).
SMART Data Structure BYTE 0-1 2-361 362 363 364-365 366 367 368-369 F/V X X V X V X F F Revision code Vendor specific Off line data collection status Self-test execution status byte Total time in seconds to complete off-line data collection activity Vendor specific Off-line data collection capability SMART capability Error logging capability 370 F 7-1 Reserved 0 1=Device error logging supported 371 372 373 374 375-385 386-395 396-397 398-399 400 X F F F R F F V V Vendor specific Short self-test routine recommended polling time (in minutes) Extended self-test routine recommended polling time (in minutes) Conveyance self-test routine recommended polling time (in minutes) Reserved Date Code Number of initial invalid block (396 = MSB, 397 = LSB) Number of run time bad block (398 = MSB, 399 = LSB) Number of spare block 1 V0. 1 Decription
Transcend Information Inc.
TS128M~8GSDOM7H
511 V Data structure checksum F=the content of the byte is fixed and does not change.
7P Horizontal Type SATA Flash Modules
V=the content of the byte is variable and may change depending on the state of the device or the commands executed by the device. X=the content of the byte is vendor specific and may be fixed or variable. R=the content of the byte is reserved and shall be zero.
* 4 Byte value : [MSB] [2] [1] [LSB]
Transcend Information Inc.
11 V0. 1
TS128M~8GSDOM7H
Table ID Table Information
Word Address 1 2 3 4 5 6 7-8 9 10-19 20 21 22 23-26 27-46 47 48 49 50 51 52 53 54 55 56 57-58 59 60-61 62 63 64 65 66 67 Default Value 044Ah XXXXh 0000h 00XXh 0000h 0240h XXXXh XXXXh XXXXh aaaa 0002h 0002h 0000h aaaa aaaa XXXXh 0000h 0F00h 0000h 0200h 0000h 0007h XXXXh XXXXh XXXXh XXXXh 0100h XXXXh 0000h 0007h 0003h 0078h 0078h 0078h Total Bytes 2 2 2 2 2 2 2 4 2 20 2 2 2 8 40 2 2 2 2 2 2 2 2 2 2 4 2 4 2 2 2 2 2 2
7P Horizontal Type SATA Flash Modules
Data Field Type Information General configuration Bit Significant with ATA-7 definitions. Default number of cylinders Reserved Default number of heads Obsolete Obsolete Default number of sectors per track Number of sectors per card (Word 7 = MSW, Word 8 = LSW) Obsolete Serial number in ASCII (Right Justified) Obsolete Obsolete Number of ECC bytes passed on Read/Write Long Commands Firmware revision in ASCII. Big Endian Byte Order in Word Model number in ASCII (Left Justified) Big Endian Byte Order in Word Maximum number of sectors on Read/Write Multiple command Reserved Capabilities ( Default) Reserved PIO data transfer cycle timing mode (PIO mode 2) Obsolete Field Validity Current numbers of cylinders Current numbers of heads Current sectors per track Current capacity in sectors (LBAs)(Word 57 = LSW, Word 58 = MSW) Multiple sector setting Total number of sectors addressable in LBA Mode Reserved Multiword DMA transfer. [. . . ] Transcend reserves the right to make changes to the specifications at any time without prior notice. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TRANSCEND TS2GSDOM7H
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.