If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TRANSCEND TS512MJF160. We hope that this TRANSCEND TS512MJF160 user guide will be useful to you.
Lastmanuals help download the user guide TRANSCEND TS512MJF160.
You may also download the following manuals related to this product:
TRANSCEND TS512MJF160 DATASHEET (56 ko)
Manual abstract: user guide TRANSCEND TS512MJF160
Detailed instructions for use are in the User's Guide.
[. . . ] It's a fastest, low-power, highly integration memory card. [. . . ] 1 2 3 4 5 6 7 Name DAT3 CMD VSS1 VDD CLK VSS2 DAT0 Type I/O/PP I/O/PP/OD S S I S I/O/PP Description Data Command/Response Ground Power supply Clock Ground
8 9 10 11 12 13
DAT1 DAT2 DAT4 DAT5 DAT6 DAT7
I/O/PP I/O/PP I/O/PP I/O/PP I/O/PP I/O/PP
Data Data Data Data Data Data Data
S: Power Supply; I:Input; O:Output; PP:Push-Pull; OD:Open-Drain; NC:Not Connected
Transcend Information Inc.
1
TS128M~4GMMC4
Multimedia Card Architecture
MMCplus
Transcend Information Inc.
2
TS128M~4GMMC4
Electrical DC Characteristics ·General bus operating conditions
Parameter
Peak voltage on all lines All Inputs Input Leakage Current (before initialization sequence and/or the internal pull up resistors connected) Input Leakage Current (after initialization sequence and the internal pull up resistors disconnected) All Outputs Output Leakage Current (before initialization sequence) Output Leakage Current (after initialization sequence) -100 -10 100 10 uA uA
MMCplus
Symbol
Min
-0. 5
Max
3. 6
Unit
V
-100 -10
100 10
uA uA
·MMC high-voltage power supply voltage
Parameter
Supply voltage Supply voltage differentials (VSS1, VSS2)
Symbol
VDD
Min
2. 7 -0. 5
Max
3. 6 0. 5
Unit
V V
· Bus Signal Line Load
The total capacitance CL of each line of the MultiMedia Card bus is the sum of the bus master capacitance CHOST, the bus capacitance CBUS itself and the capacitance CCARD of the card connected to this line: CL = CHOST + CBUS + CCARD
Parameter
Pull-up resistance for CMD Pull-up resistance for DAT0-7 Internal pull up resistance DAT1-DAT7 Bus signal line capacitance Single card capacitance Maximum signal line inductance
Symbol
RCMD RDAT Rint CL CCARD
Min
4. 7 50 50
Max
100 100 150 30 7 16
Unit
KOhm KOhm kOhm pF pF nH
Remark
to prevent bus floating to prevent bus floating to prevent unconnected lines floating Single card fPP <= 52 MHz
Transcend Information Inc.
3
TS128M~4GMMC4
· Open-drain mode bus signal level
Parameter
Output HIGH voltage Output LOW voltage
MMCplus
(Ta=-25 to 85, VDDH=2. 7V to 3. 6V)
Symbol
VOH VOL
Min.
VDD-0. 2 V
Max.
0. 3
Unit
V V
Condition
IOH = -100 A IOL = 2 mA
· Push-pull mode bus signal level--high-voltage MultiMedia Card
(Ta=-25 to 85, VDDH=2. 7V to 3. 6V)
Parameter
Output HIGH voltage Output LOW voltage Input HIGH voltage Input LOW voltage
Symbol
VOH VOL VIH VIL
Min.
0. 75*VDD
Max.
0. 125*VDD
Unit
V V V V
Condition
IOH=-100 A @VDD min IOL=100 A @VDD min
0. 625*VDD VSS-0. 3
VDD + 0. 3 0. 25*VDD
Transcend Information Inc.
4
TS128M~4GMMC4
Electrical AC Characteristics
· Card interface timings
MMCplus
(Ta=-25 to 85, VDDH=2. 7V to 3. 6V)
Parameter
Clock Frequency (Data Transfer Mode) Clock Frequency (Identification Mode) Clock Low Time Clock Rise Time Clock Fall Time Input Set-up Time Input Hold Time Input Set-up Time Input Hold Time Signal Rise Time Signal Fall Time
Symbol
fpp fOD tWL tTLH tTHL tISU tIH tOSU tOH trise tfall
Min.
0 0 6. 5
Max.
26/52 400 3 3
Unit
Notes
CL <= 30 pF MHz Tolerance: +100KHz KHz Tolerance: +20KHz ns ns ns ns ns ns ns CL <= 30 pF CL <= 30 pF CL <= 30 pF CL30pF CL30pF CL30pF CL30pF CL30pF CL30pF
Inputs CMD, DAT (referenced to CLK)
3 3 5 5 3 3
Outputs CMD, DAT (referenced to CLK)
ns ns
NOTE 1. All timing values are measured relative to 50% of voltage level NOTE 2. A Multimedia Card shall support the full frequency range from 0-26Mhz, or 0-52MHz NOTE 3. hum. /500h Salt Water Spray: 3% NaCl/35C; 24h acc. MIL STD Method 1009 Contact Pads: +/-4kV, Human body model according to ANSI EOS/ESD-S5. 1-1998 Non Contact Pads area: +/-8kV(coupling plane discharge) +/-15kV(air discharge) Human body model according to IEC61000-4-2 UV: 200nm, 15Ws/cm² according to ISO 7816-1
MMCplus
Moisture and corrosion
ESD protection
UV light exposure Visual inspection Shape and form
No warp page; no mold skin; complete form; no cavities surface smoothness sigma -0. 1 mm/cm² within contour; no cracks; no pollution (fat, oil dust, etc. )
Above technical information is based on MMC4. 2 standard specification and tested to be reliable, but SPI mode would not be supported. Transcend makes no warranty, either expressed or implied, as to its accuracy and assumes no liability in connection with the use of this product. [. . . ] Transcend makes no warranty, either expressed or implied, as to its accuracy and assumes no liability in connection with the use of this product. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TRANSCEND TS512MJF160
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TRANSCEND TS512MJF160 will begin.