[. . . ] FCC Warning
This equipment has been tested and found to comply with the regulations for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user's guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense.
CE Mark Warning
This is a Class A product. [. . . ] The Switch can be configured through the Web Browser. A network administrator can manage, control and monitor the switch from the local LAN. This section indicates how to configure the Switch to enable its smart functions
Login
Before you configure this device, note that when the Web Smart Switch is configured through an Ethernet connection, make sure the manager PC must be set on same the IP network. For example, when the default network address of the default IP address of the Web Smart Switch is 192. 168. 0. 1, then the manager PC should be set at 192. 168. 0. x (where x is a number between 2 and 253), and the default subnet mask is 255. 255. 255. 0. Open Internet Explorer 5. 0 or above Web browser. Enter IP address http://192. 168. 0. 1 (the factory-default IP address setting) to the address location.
Figure 14.
Or through the Web Management Utility, you do not need to remember the IP Address, select the device shown in the Monitor List of the Web Management Utility to settle the device on the Web Browser. When the following dialog page appears, remain enter the default password "admin" and press Login to enter the main configuration window.
30
Figure 15.
After entering the password, the main page comes up, the screen will display the device status.
Figure 16. System Information
31
Setup Setting
Find that there are seven items, including Port Setting, IEEE 802. 1Q VLAN Settings, Trunk Setting, Mirror Setting, IEEE 802. 1p Default Priority, Broadcast Strom Control Setting, Jumbo Frame Setting in Setup menu. Port Settings In Port Settings menu (Figure 17), this page will show each port's status, selected drop down menu to set each port's Speed, and QoS priority then press "Apply" button to activate changes. To refresh the information table to view the latest port setting and Link Status, press the Refresh button. The Link Status in the screen will show the connection speed and duplex mode; else this dialog box will show Down when the port is disconnected.
Figure 17. Port Setting
32
Note: The priority of Gigabit Fiber port is higher than Copper.
Speed: The 1000BASE-T connections can operate in Forced Mode settings (1000M Full, 100M Full, 100M Half, 10M Full, 10M Half), Auto, or Disable. The default setting for all ports are Auto. The mini-GBIC (Gigabit Fiber) connections can operate in Forced Mode settings (1000M Full), Auto, or Disable Flow Control: This setting determines whether or not the Switch will be handling flow control. Set Flow Control to Enable for avoiding data transfer overflow. Or it sets to Disable; there is either no flow control or other hardware/software management. When the port is set to forced mode, then the flow control will automatically set to Disable. QoS: Displays each port's 802. 1p QoS priority level for received data packet handling. Default setting for all ports is Middle. You can change the priority settings in 802. 1p Default Priority. IEEE 802. 1Q VLAN A VLAN is a group of ports that can be anywhere in the network, but communicate as though they were in the same area. VLANs can be easily organized to reflect department groups (such as R&D, Marketing), usage groups (such as e-mail), or multicast groups (multimedia applications such as video conferencing), and therefore help to simplify network management by allowing users to move devices to a new VLAN without having to change any physical connections.
33
The IEEE 802. 1Q VLAN Configuration page provides powerful VID management functions. [. . . ] To restore a current setting file to the device, you must specify the backup file and press "Restore" button to proceed the setting of the recorded file.
Figure 34. Backup Setting Note: when restoring a recorded file, the current password will not be erased.
66
Firmware Upload The Firmware Upload helps you backup or upload firmware from/to the Switch. Once you need to backup the current firmware of the Switch, press the "Backup" button to save the current firmware of the Switch; To restore or upgrade firmware to the Switch, you must specify the firmware file and press "Upload" button to proceed the firmware upload.
Figure 35. Firmware Upload
System Reboot Provides to a safe way to reboot the system and ensures the configuration has been saved, or all the changes you just made may be lost after system reboot.
Figure 36. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TRENDNET TEG-448WS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.