User manual TRENDNET TK-RP08

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TRENDNET TK-RP08. We hope that this TRENDNET TK-RP08 user guide will be useful to you.

Lastmanuals help download the user guide TRENDNET TK-RP08.


Mode d'emploi TRENDNET TK-RP08
Download

You may also download the following manuals related to this product:

   TRENDNET TK-RP08 QUICK INSTALLATION GUIDE (903 ko)

Manual abstract: user guide TRENDNET TK-RP08

Detailed instructions for use are in the User's Guide.

[. . . ] FCC Warning This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user's guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference to household appliances, in which case the user will be required to correct the interference at his/her own expense. CE Mark Warning This is a Class B product. [. . . ] Pease be sure to have (4) the latest flash upgrade file (*. x) ready on your local computer. You can copy them from the diskette/CD-ROM provided by the technical support or download it from available support website. Click OK. Configure your port setting with the following parameters: Bits per seconds: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow Control: Hardware Check the connection between the Unit and PC TK-RP08 Make sure you have powered on the PC and also the TK-RP08 Unit before you perform the flash upgrade procedure. Step 1. Connect your PC and the TK-RP08 Unit using a RS232 cable. Setting the Windows HyperTerminal Once you have successfully established a serial connection, the settings will be stored on your PC and a shortcut with the connection's name generated under your HyperTerminal program menu. Next time, you can establish the connection again simply by clicking the connection shortcut without going over the procedure in this section again. If that is the case, just click the connection shortcut and go right to the last section, Flash Upgrade File Transfer. Step 2. On your PC (which should already be connected to your ioPower Unit with a DB9-to-DB9 RS-232 cable), activate the Windows HyperTerminal (Start/Programs/Accessories/Communications/Hyper Terminal). Designate your HyperTerminal connection with a specific name, e. g. Power Control 01. Click Apply then click OK. Then HyperTerminal windows appears. . . . . Step 5. Hit Enter key twice to go into command mode . . . . . 7 Flash Upgrade File Transfer Step 7. To start loading the file, access the drop-down menu on HyperTerminal: Transfer/Send Text File. . . . If the firmware version is lower than 040421, here you should type in / TK-RP08 \ on the command line and then hit Enter to go into command mode. On the HyperTerminal window, you'll see the Testing OK message and the existing firmware version number. . . . . . . . . and a dialog box will prompt you to select the flash upgrade file, *. x (with a file extension name as . x). In this case, we have our flash upgrade file as TK-RP08 3. 0. 1_040907. x (it could be any other file name with an . x extension!). Note that since it has an extension name other than . txt, we have to select the "All file [*. *]" option in order to see it on the file listing. . . Step 6. Type Upgrade on the command line and hit Enter. . . Now you have your HyperTerminal ready for file transfer. Keep your HyperTerminal window open and go to the next step. . . . Then select our target file: PowerGate. hex. bin. x. And then Click Open to begin the file transfer . . . . . When the file transfer is completed, you will see the message: OK!!Please Restart on the HyperTerminal window to tell you that Flash Upgrade process is successful. . . . 8 Troubleshooting If the flash upgrade procedure seems never ending or you see the following message: Please send new firmware, shown on the screen, it indicates that the flash process had failed. If that is the case, please power off the TK-RP08 Unit and then power it on restart the whole flash procedure again. You also press any button on front panel about 3 seconds when you power on the TK-RP08 Unit. Step 8. [. . . ] A port number of 0 represents all ports; while a bank number of 0 represents all cascaded banks. The command: TA 0 0x . . . . . . . . . , x = 1~9, is not valid. The system time should be calibrated before use for the first time. TF ­ Timer Activate after specific time duration [Description]Set the timer to turn on/off a specific port after specific time duration [Usage] TF [bank_number] [port_number] [ON | OF] [Time_duration] [Examples] TF 1 4 ON 03:25:56 ­ Set timer to power on port 4 on bank 1 exactly after 3 hour 25 minutes and 56 seconds. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TRENDNET TK-RP08

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TRENDNET TK-RP08 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag