Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TRICITY TBG700X. We hope that this TRICITY TBG700X user guide will be useful to you.
Lastmanuals help download the user guide TRICITY TBG700X.
Detailed instructions for use are in the User's Guide.
[. . . ] User Manual
Gas Hob
TBG700
Welcome to the world of Electrolux Thank you for choosing a first class product from Electrolux, which hopefully will provide you with lots of pleasure in the future. The Electrolux ambition is to offer a wide variety of quality products that make your life more comfortable. You find some examples on the cover in this manual. Please take a few minutes to study this manual so that you can take advantage of the benefits of your new machine. [. . . ] Pay attention when replacing the pan supports in order to avoid damaging the hob top.
10
The Burners
The burner caps and crowns can be removed for cleaning. Wash the burners caps and crowns using hot soapy water, and remove marks with a mild paste cleaner. A well moistened soap impregnated steel wool pad can be used with caution, if the marks are particularly difficult to remove. After cleaning, be sure to wipe dry with a soft cloth.
The Ignition electrode
The electric ignition is obtained through a ceramic electrode and a metal electrode . 70 Adjust.
NOZZLE REFERENCE 1/100 mm
NOMINAL THERMAL
LPG GAS 28-30/37 mbar VALUE = 49. 92 MJ/Kg
POWER NOMINAL FLOW RATE
kW g/h
2. 8 202 86
0. 65 47 40
2. 0 144 71
0. 45 32 32
1. 0 72 50
0. 33 24 28
4. 0 288 98
1. 2 86 56
NOZZLE REFERENCE 1/100 mm
Burner Auxiliary Semi-rapid Rapid Triple crown
Dia. Tap By-pass 1/100 mm 28 32 40 56
Aeration adjustment none
14
Important safety requirements
This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S. 813 Current Editions and the ETCI Rules for Electrical Installations. Provision for Ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice: B. S. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B. S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. For appliances installed in the Republic of Ireland please refer to the NSAI- Domestic Gas Installation I. S. 813 Current Editions Table Four.
Location
The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm between the rear edge of the hob and the wall. A minimum distance of 100 mm must be left between the side edges of the hob and any adjacent cabinets or walls. The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm If it is fitted below 400 mm a space of 50 mm 5must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. For appliances installed in the Republic of Ireland please refer to NSAI- Domestic Gas Installation I. S 813 Current Edition Section 7- Permitted Locations of Appliance.
15
CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE
600 mm
CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WITH A COOKER HOOD ABOVE
600 mm
700 mm
700 mm
400 mm
400 mm
m 55 m
400 mm
55
mm
400 mm
100 mm
100
mm
50 m
m 50 m m
50 m
m 50 m m
Installation
IMPORTANT This hob must be installed by a competent person to the relevant Gas Standards. [. . . ] The pressure reading should be nominally 20 mbar and must be between 17 mbar and 25 mbar. 4) Turn off the burner supplies.
26
Conversion from Natural Gas to LPG
IMPORTANT
The replacement/conversion from natural gas to LPG should only be undertaken by a competent person. It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. The gas rate is adjusted to suit.
Method
1) Ensure that the gas taps are in the 'OFF' position 2) Isolate the hob from the electricity supply 3) Remove all pan supports, burner caps, rings, crowns and control knobs. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TRICITY TBG700X
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TRICITY TBG700X will begin.