[. . . ] User Manual
Elta R 45, Elta R 55, Elta R 50 Routine Total Stations Software version , , Construction"
Contents
1 Introduction Dear Customer The System Philosophy Important Notes 1-2 1-3 1-4
2 Elta® R The Routine Total Stations
Instrument Description Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 The Routine Total Stations Elta® R. . . . . . . . . . . . . . . . . . . . . 2-3 Overview about " Construction " . . . . . . . . . . . . . . . . . . . . . . 2-4 Overview about " Topo ". . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Editor 6-2
Data Transfer
6-8
Data Formats
6-13
Interface
6-31
Remote Control
6-33
Data Record Lines
6-41
Updates
6-47
6-1
Data Management
Calling the EDIT Menu ON EDIT
Editor
Compensator activated Indication of battery level Display of the free data lines and address of the last data line written
Display of Data Lines
Disp
to go to memory display to call search function to change page to display preceding data line to display following data line .
?
ON
PNo
allows to change point number and code
Attention !In the coordinate and application programs, fixed codes are assigned to certain data lines. Such codes cannot be modified by the operator.
6-2
Data Management
Searching for Data Lines
?
Editor
to call search function to search for point number to search for code to search for address Input of the point number, code or address to be searched for
?P
?C ?A
?
to continue search using the same criterion to change page to display preceding data line to display following data line
ESC
to quit search routine
Tip If no data line is found to which the search criterion applies, search is followed by an error message.
6-3
Data Management
Deleting Data Lines
Del
Editor
to call the function "Delete"
Technical Information This function deletes all data lines or the data lines from a selected line number (address) to the last data line saved.
Attention !The deletion is definite and irrevocable. To avoid any unintentional loss of data, utmost care has to be taken over this action!
all ?P
to select all lines or from the line with point number xx or from the line with code xx or from the line with address xx
?C
?A
6-4
Data Management
Editor
Example: search for point number 2
?
to continue search using the same criterion
to switch over to the page of readings
o. k.
to confirm the line
For another check, the selected data lines are displayed again and have to be confirmed.
YES
to confirm the selection to reject the selection / quit the routine
NO
6-5
Data Management
Entering Data Lines
Inpt
Editor
to call the function "Input"
XY
to enter the planimetric coordinates to enter planimetric coordinates and heights to enter heights
XYZ
Z
Example of a height input: Z 149, 362 m Confirmation of the old value (in this case 149, 362 m) Z=0 Set the height to zero
Principles First steps
6-6
Data Management
and to go to the desired position
+
Editor
and to browse through digits to confirm
o. k.
to switch over to the page for readings
ON PNo
to enter point number and code to confirm and save
o. k.
Input of further coordinates and heights with point number and code
Presettings First steps
Attention !The sequence and designation of the coordinate axes depend on the selected system of coordinates and the setting of the display of coordinates. The softkey YX and YXZ, respectively, is labelled according to this selection.
6-7
Data Management
Data Transfer
Cable
Data transfer can be performed between and by Elta R
PC
Cable
This allows an easy data exchange between instrument and computer.
6-8
Data Management
Data Transfer
Preparing the Instrument for Data Transfer ON
YES MOD
MENU
5 Interface
to go to the menu to change settings
Menu Interface Elta R
Elta S PC Connect both devices by the serial interface cable and start the necessary programs for data transfer.
Interface parameters for transmitting and receiving project files: Baud rate: Protocol: Parity: Stop bits: Data bits: Tip For data transfer to and from the PC, you can use for example the MS-WindowsTM Terminal program. 9600 Xon/Xoff even 1 (not variable) 8
Cable for data transfer Elta R PC cable with protocol Xon/Xoff: Order number 708177-9470. 000
6-9
Data Management
PC Terminal Settings
Data Transfer
Set the PC for data transfer as follows: Example for Windows Terminal program:
TM
3. xx
For sending or receiving a project file, set the terminal preferences as shown in the follows:
To transmit a project file, select "Send text file" or "Receive text file".
6-10
Data Management
Data Transmission
Data Transfer
Instrument Settings:
5 Interface YES
to go to the menu to confirm
Data transfer menu between Elta R and PC
1 MEM -----> Peripheral YES
Selection of the required data lines
Editor Data Management
Tip Now, set the PC to , , Receive text file". The instrument or program at the receiving end must be set to the receive mode before you can transmit the project file.
YES
to start
The data lines are transferred to the PC.
ESC
to end data transfer
6-11
Data Management
Data Reception
Data Transfer
On the instrument:
5 Interface YES
to go to the menu to confirm
Data transfer menu between PC and Elta R
2 Peripheral -----> MEM YES
Enter the name of the source file into the PC Start the transfer from the PC The data lines are transferred to the Elta R.
Attention !The instrument only accepts coordinates.
ESC
to end data reception
Tip Time Out occurs after 30 seconds without data communication. The message , , Time Out" indicates a data error. After that, the program returns to the data transfer menu.
6-12
Data Management
Introduction
Data Formats
Zeiss Geodetic Systems are used for measurement functions with different data processing requirements. Elta ® instruments allow densely packed internal measurement and result data lines to be output in various formats. M5, R4, R5, Rec500 record format Four data formats which have grown historically are subject to on-site revision service for compatibility with customer instruments. Currently, M5 is the format to provide most comprehensiveness in definitions. It should be used preferentially for any other tasks. This chapter describes the structure of data format and the type identifier of measured and calculated values.
Data transfer Data management User interface Data management
Technical All instruments have a serial interface which ensures the data exchange.
Attention!Instead of the usual marks within the 27 digit point identification, the M5 data format of Elta * R is limited to a 12 digit point number and a 5 digit code.
6-13
Data Management
Data Formats
Description of M5 data format , , M5" -> 5 Measuring data blocks per data line: 1 Address block 1 Information block 3 numerical data blocks The Zeiss M5 data format is the common standard for all current Carl Zeiss surveying systems. All 5 data blocks are preceded by a type identifier. The 3 numerical data blocks have a standard layout comprising 14 digits. In addition to the decimal point and sign, they accept numeric values with the specified number of decimal places. The information block is defined by 27 characters. [. . . ] Read out the memory content, delete the memory. Correct the entry.
410
MEM not initialised!
411/ 412 413 415 416 417 418 419 581 584 586 587 588
Defect in system area Defect in system area, reading is possible MEM reading error MEM writing error
MEM is full
Pointcode or Pointnumber not found
Transmission error (in data transmission) Transmission time out (in XON/XOFF protocol) Transmission time out (in XON/XOFF Rec 500 protocol) I/O time out, Rec 500 protocol REC 500 protocol error
If the general recording errors 518. . . 588 occur, first try to repeat recording. If the error occurs again, check the interface parameters, the cable and the recording program at the other end.
8-25
Annex
Error Messages
Tip If the warning "inadequate geometrical conditions" is ignored in the application programs, the last digit of the displayed values is replaced by 3 dots. If a recording error occurs, the last data line has usually not been transmitted.
Before you call the service Before you contact the service please notice the following service menu information. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TRIMBLE ELTA R50
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.