User manual TRIMBLE EZ-BOOM 2010 QUICK REFERENCE FOR EZ-GUIDE 500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual TRIMBLE EZ-BOOM 2010. We hope that this TRIMBLE EZ-BOOM 2010 user guide will be useful to you.

Lastmanuals help download the user guide TRIMBLE EZ-BOOM 2010.


Mode d'emploi TRIMBLE EZ-BOOM 2010
Download
Manual abstract: user guide TRIMBLE EZ-BOOM 2010QUICK REFERENCE FOR EZ-GUIDE 500

Detailed instructions for use are in the User's Guide.

[. . . ] From the main guidance screen, select the The Configuration screen appears. Select Application Control and then press o. Configure the following settings: Setting Fence Nozzles Description Fence nozzles are spray sections at the far end of the boom that point out to the sides to cover any fence lines. On the EZ-Boom controller, Switch 1 controls the left fence nozzle, and the first switch after the boom section switches controls the right nozzle. [. . . ] Set the following settings: Setting Type step 6. Configuring the flow Control ValVe Description The flow control valve type: · If you select Inline Servo, Bypass Valve, or Pump Servo, the Response 1, Response 2, Threshold, and Close on Zero Flow options appear. · If you select PWM or Grounded PWM, the Close on Zero Flow, Frequency, Gain, and Zero Flow Offset options appear. The desired adjustment speed of the valve when the application rate is outside the threshold. The desired adjustment speed of the valve when the application rate is within the threshold. The point at which the application rate is close enough to the target rate for the application speed of the valve to switch from Response 1 to Response 2. How the valve responds when there is no flow. The shut-off point of the PWM valve. Inline/Bypass/Pump All PWM Response 1 Response 2 Threshold Close on Zero Flow Frequency Gain Zero Flow Offset 3. Press to exit the Control Valve Setup screen. www. EZ-Boom. com EZ-BoomTM 2010 System for the EZ-Guide® 500 Lightbar Quick Reference Card step 7. From the Application Control screen, select Tank Setup. Configure the following options: Setting Capacity Current Volume Low Limit Tank Refill Method Description The capacity of the tank when full. This amount decreases as you use the spray solution. When the volume reaches this level, a warning appears. The method that you will use to fill the tank: · Partial Refill = If you add a specific amount of solution to the tank. (If you select Partial Refill, the Partial Refill Quantity option appears). · Refill = If you fill the tank to capacity. The amount that you add when you partially fill the tank. Partial Refill Quantity 3. Press to exit the Tank Setup screen. step 8. Calibrating the pressure If your sprayer has a pressure transducer fitted, you can use it to display pressure information on the EZ-Boom information tab. To calibrate the pressure, ensure that the transducer is connected to the correct input on the EZ-Boom system (refer to the EZ-Boom system pinout information in the EZ-Boom 2010 Automated Application Control System Troubleshooting Guide) and then follow the steps below. If you want pressure information to appear on the EZ-Boom information tab and there is not already a pressure transducer on the sprayer, install one. Note - The system operates correctly without a pressure transducer. [. . . ] ­ To fine tune the calibration, adjust the following settings: Setting Target Rate Speed Total Nozzles Description Set the expected application rate. Specify the number of boom nozzles that will be turned on during the calibration. Do not count the fence nozzles. Note - Turn on all the boom nozzles (but not the fence nozzles), and make sure that they are operational. Measure the volume from 3 nozzles separately for a total of 1 minute. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TRIMBLE EZ-BOOM 2010

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual TRIMBLE EZ-BOOM 2010 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag