Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAILLANT VAM 2-060 W2N. We hope that this VAILLANT VAM 2-060 W2N user guide will be useful to you.
Lastmanuals help download the user guide VAILLANT VAM 2-060 W2N.
Manual abstract: user guide VAILLANT VAM 2-060 W2NINSTALLATION
Detailed instructions for use are in the User's Guide.
[. . . ] climaVAIR
VAM 2-050 W2N VAM 2-060 W2N VAM 2-085 W3N VAM 2-110 W4N
DE, EN, HR, IT, TR
For the fitter
Installation Manual
Air-conditioner - climaVAIR
Split Type
VAM 2-050 W2N VAM 2-060 W2N VAM 2-085 W3N VAM 2-110 W4N
EN
Contents
Contents
1 1. 1 1. 2 2 3 4 5 5. 1 5. 2 5. 3 5. 4 5. 5 5. 6 6 7 8 8. 1 8. 2 8. 3 9 9. 1 9. 2 9. 3 9. 3. 1 9. 3. 2 9. 3. 3 9. 3. 4 9. 3. 5 9. 3. 6 10 10. 1 10. 2 10. 3 10. 4 11 11. 1 11. 2 11. 3 11. 4 11. 5 Your Safety . 8 Qualification of the Installation Personnel . 8 General precautions to be taken into account before starting the installation . 10 Correct Removal of the Condensate Water. [. . . ] 9. 1 Dimensions of the hole for the piping.
· Case B: Running the pipework out of either side or the bottom of the unit. In this case holes do not have to made in the wall since the indoor unit body has knock outs which can be opened to allow the pipes to exit the unit: choose the most convenient one for the desired outlet position (see Figure 9. 7). · Carefully break the knock out in the casing using pliers.
Fig. 9. 7 Windows for the installation of the pipes. Legend 1 Exit for right piping 2 Exit for indoor piping 3 Securing with adhesive tape 4 Exit for left piping
Fig. 9. 8 Assembling the indoor unit.
· Connect the coolant pipes from the outdoor unit and the condensed water hose to the installation drain. · Insulate the coolant piping and joints correctly and separately. To do so, cover any possible cuts with masking tape or insulate any bare coolant piping with the corresponding insulation material suitable for air conditioning installations (for connection of the electrical wiring see section 11).
12
Split Type Installation Manual
Installation of the indoor unit 9 Installation of the outdoor unit 10
10 Installation of the Outdoor Unit
10. 1 Selecting the Assembly Location Warning!Outdoor units must be placed in accessible areas for subsequent maintenance and repair operations. Vaillant will not be responsible for any costs derived from incorrect positioning that prevents easy access. Danger of personal injury and material damage from explosion!Install the unit away from inflammable gasses or liquids or easily combustible substances and free from thick dust formation. Danger of personal injury and material damage from collapse!Ensure that the ground is smooth and level and can withstand the weight of the outdoor unit. Do not install the unit near to corrosive materials. - The outdoor unit can only be mounted outdoors, never inside a building. - Do not install the unit in such a way that the air discharge affects the air inlets of premises nearby. - Ensure that the ground has sufficient rigidity to avoid vibrations. - Ensure that there is sufficient space to observe the minimum distances (see Figure 8. 1). - Ensure that neighbours are not disturbed by draughts or noise. - If the premises are rented obtain the owner's consent. - Comply with local regulations: there are considerable differences dependant on the area. [. . . ] · Check the manometer needle after approximately 1015 minutes have elapsed: the pressure should not rise. If it does rise, there are leaks in the circuit: repair them (Check all joints and connections to the service manifold carefully as the leak may be here). · Close the valves on the service manifold and disconnect the vacuum pump. Do not proceed to the next step until a satisfactory evacuation of the installation has been completed
· Open the two-way valve by twisting the allen key 90º anticlockwise and close it after 6 seconds. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAILLANT VAM 2-060 W2N
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAILLANT VAM 2-060 W2N will begin.