[. . . ] USER'S GUIDE
Vaisala DRYCAP® Dewpoint Transmitter DMT152
M210865EN-D
PUBLISHED BY Vaisala Oyj P. O. Box 26 FIN-00421 Helsinki Finland Phone (int. ): +358 9 8949 1 Fax: +358 9 8949 2227
Visit our Internet pages at http://www. vaisala. com/ © Vaisala 2008 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice.
Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.
________________________________________________________________________________
Table of Contents
CHAPTER 1
GENERAL INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Table 4
Property Baud rate Parity Data bits Stop bits Flow control
DMT152 Default Serial Interface Setting
Description / Value 19200 None 8 1 Xon/Xoff (none)
The steps below describe how to connect to the DMT152 using the PuTTY terminal application for Windows (available for download at www. vaisala. com) and a USB serial interface cable:
30 __________________________________________________________________ M210865EN-D
Chapter 5 ________________________________________________________________ Operation
1. 3.
Connect the USB serial interface cable between your PC and the RS-485 port of the DMT152 (port II). Select the Serial settings category, and check that the correct COM port is selected in the Serial line to connect to field. Note: You can check which port the USB cable is using with the Vaisala USB Instrument Finder program that has been installed in the Windows Start menu.
4.
Check that the other serial settings are correct for your connection, and change if necessary. Flow control should be set to None unless you have a reason to change it. Click the Open button to open the connection window and start using the serial line. Note: If PuTTY is unable to open the serial port you selected, it will show you an error message instead. If this happens, restart PuTTY and check the settings.
5.
6.
You may need to adjust the Local echo setting in the Terminal category to see what you are typing on the serial line. To access the configuration screen while a session is running, click the right mouse button over the session window, and select Change Settings. . . from the pop-up menu.
0807-004
Figure 16
PuTTY Terminal Application
VAISALA _______________________________________________________________________ 31
User's Guide ______________________________________________________________________
List of Serial Commands
All commands can be issued either in uppercase or lowercase. The notation <cr> refers to pressing the carriage return (Enter) key on your computer keyboard. Enter a <cr> to clear the command buffer before starting to enter commands.
NOTE
The DMT152 does not output the ">" prompt that is used in the output examples of this manual. The prompt has been added for clarity of the examples.
Table 5
DMT152 Serial Commands
Description Show device information Show device information (overrides poll mode) Calibrate analog channel Set the transmitter address for POLL mode Set analog output device malfunction error mode Set analog output limit alarm modes Set analog output mode Allow analog outputs to exceed their range 10% Configure analog output quantities and scaling Test analog outputs Close the temporary connection and return the device to POLL mode Display the currently active errors Change the format of the measurement output Restore factory settings Display the command list Set the continuous output interval (for RUN mode and R command) Set the molar mass of the process gas (used in ppmw calculation) Open temporary connection to a device that is in POLL mode Set value for pressure compensation Start the continuous outputting Reset the transmitter Stop the continuous outputting Set response sending delay in milliseconds Output the reading once Set the serial interface settings Set the serial interface mode Display transmitter status Set analog output self-diagnostic alarm Set time for transmitter clock
Command ?99] AERR ALARM AMODE AOVER [ON/OFF] ASEL ATEST CLOSE ERRS FORM FRESTORE HELP INTV [0 . . . 99] SERI SMODE [RUN/POLL/STOP] STAT STATUS TIME
32 __________________________________________________________________ M210865EN-D
Chapter 5 ________________________________________________________________ Operation
Command UNIT VERS XPRES XPUR [ON/OFF]
Description Select metric or non-metric units Display transmitter software version Set value for pressure compensation (temporarily, is cleared at reset) Enable or disable sensor purge (temporarily, is enabled at reset)
Device Information and Status Show Device Information
The ?command outputs a listing of device information. DMT152/1. 10 Serial number : Batch number : Module number : Sensor number : Cal. info : Serial mode : Baud P D S : Output interval: Address : Pressure : Filter : Ch1 output : Ch2 output : Ch1 Tdf lo : Ch1 Tdf hi : Ch2 Tdf lo : Ch2 Tdf hi :
D1930026 D1330070 ????????C1420000 20080512 Vaisala/HEL STOP 19200 N 8 1 1S 0 1. 0132 bar 1. 000 0 . . . 5 V U ALARM -80. 00 'C 20. 00 'C 0. 00 'C 0. 00 'C
If the transmitter is in poll mode, but a connection has not been opened using the OPEN command, issue the ??For a description of the serial interface modes, see section Set Serial Interface Mode on page 42. ??<cr>
VAISALA _______________________________________________________________________ 33
User's Guide ______________________________________________________________________
Show Transmitter Status
The STAT command displays the status of the transmitter in four characters. [. . . ] command to view the transmitter settings, including the serial settings and address. For an output example, see section Show Device Information on page 33. You may have to give the command several times if there are characters in the buffer. If necessary, set new serial line settings using the SERI command. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA DMT152 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA DMT152 will begin.