Manual abstract: user guide VAISALA GMM111DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] www. vaisala. com
GMM111 Carbon Dioxide Module
The Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is a CO2 measurement module with flow-through aspiration.
Features/Benefits
GMM111
The Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is designed especially for control of biological processes where high CO2 concentrations are used. It has 3 optional measurement ranges 0 . . . [. . . ] 20 % CO2 Excellent long-term stability
CARBOCAP® sensors results largely from the stable reference provided by the electrically tunable Fabry-Perot Interferometer(FPI). The tunable FPI filter measures CO2 absorption, and simultaneously a reference wavelength. This internal reference measurement compensates effectively for any changes in the optical path, such as light source intensity changes and contamination. In the HVAC market, this type of reference measurement is a unique feature to Vaisala CARBOCAP® products. The true internal reference measurement of Vaisala CARBOCAP® CO2 transmitters provides years of stable CO2 measurements.
Technical data
Performance
CO2 measurement range 0 . . . 20 % Accuracy (including repeatability, non-linearity and calibration uncertainty) ±(1. 5% of range + 3 % of reading) Long-term stability ±1 % CO2/2 years 1 min at 0. 5 l/min flow Response time T90 Flow rate dependence < 1 l/min flow no effect 1 . . . 10 l/min flow 4 % of reading/ l/min Temperature dependence, typical -0. 3 % of reading/°C Pressure dependence, typical +0. 15 % of reading/hPa Warm-up time 1 min, 10 min for full specifications Product lifetime > 10 years
Dimensions
Dimensions in mm
mA V 0 B A 0 24V
mA V 0 B A 0 24V
25
Ø3. 2
TUBE I. D. Ø6)
30
6
65
60
Operating environment
Temperature +5 . . . 1200 hPa Gas flow operating range < 10 l/min recommended range 0. 2 . . . 0. 8 l/min Electromagnetic compatibility Complies with EMS Standard EN61326-1, Generic Environment
Inputs and outputs
Outputs Operating voltage Power consumption 4 . . . [. . . ] The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications -- technical included -- are subject to change without notice.
96 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA GMM111
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA GMM111 will begin.