User manual VAISALA HMM212

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA HMM212. We hope that this VAISALA HMM212 user guide will be useful to you.

Lastmanuals help download the user guide VAISALA HMM212.


Mode d'emploi VAISALA HMM212
Download
Manual abstract: user guide VAISALA HMM212

Detailed instructions for use are in the User's Guide.

[. . . ] USER'S GUIDE Vaisala HUMICAP Humidity and Temperature Module HMM212 ® U338EN-1. 2 PUBLISHED BY Vaisala Oyj P. O. Box 26 FI-00421 Helsinki Finland Phone (int. ): +358 9 8949 1 Fax: +358 9 8949 2227 Visit our Internet pages at http://www. vaisala. com/ © Vaisala 2009 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. [. . . ] Furthermore, the customer can also order the module with: - a suitable cable length (0. 65 m, 1. 50 m or 3. 0 m) - a temperature loop current scaled for that particular application (0 . . . +180 °C) The HMM212 modules are connected to process control systems with screw terminals. These versatile modules incorporate the HUMICAP®180R humidity sensor, which uses an operating principle based on changes in the capacitance of a thin polymer film as it absorbs water molecules. The HMM212 modules measure temperature with the reliable Pt 1000 sensor. VAISALA _______________________________________________________________________ 13 USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 14 ____________________________________________________________________ U338EN-1. 2 Chapter 3 ________________________________________ To Be Noted When Measuring Humidity CHAPTER 3 TO BE NOTED WHEN MEASURING HUMIDITY This chapter describes issues that need to be noted in the measurement of humidity. In the measurement of relative humidity and especially in calibration, it is essential that the temperature equilibrium is reached. Even a slight difference in the temperature between the measured object and the sensor causes an error. For example, at +20 °C (+ 68 °F) and 50 %RH, a temperature difference of ±1 °C between the measured object and the sensor causes an error of ±3 %RH. If relative humidity is 90 %RH, the error is about ±5. 4 %RH. A graph of the measurement error at 100 %RH when the temperature difference between ambient air and the sensor is 1 °C is presented in Figure 1 on page 16. The error is at its greatest when the temperature of the sensor differs from that of the surroundings and the humidity is high. A difference of a few degrees in temperature may cause water to condense on the sensor surface. Efficient ventilation accelerates the evaporation of the condensed water whereas in an unventilated space, it may take hours. The HUMICAP®180R sensor returns to its normal functioning as soon as water has evaporated. Contaminated water condensing on the sensor may shorten its life span and alter the calibration. VAISALA _______________________________________________________________________ 15 USER'S GUIDE____________________________________________________________________ 9 8 7 dRH (%RH) 6 5 4 3 2 1 0 -40 -20 0 20 40 60 80 100 Temperature (°C) Figure 1 Measurement Error at 100 %RH when the Temperature Difference between the Ambient Air and the Sensor is 1 °C 16 ____________________________________________________________________ U338EN-1. 2 Chapter 4 _______________________________________________________________ Installation CHAPTER 4 INSTALLATION This chapter provides you with information that is intended to help you install this product. Selecting Location Finding a suitable site for HMM212 is important for getting representative ambient measurements. Select a place that gives a true picture of the environment or process and is as clean as possible. Air should flow freely around the sensor. Install the sensor head to a sufficient distance from the duct or chamber walls. Make sure to insert enough cable to the same space with the probe in order to prevent heat conduction. VAISALA _______________________________________________________________________ 17 USER'S GUIDE____________________________________________________________________ Dimensions Figure 2 Dimensions in mm (inches) Electrical Connections Connect wires according to Figure 3 on page 19. 18 ____________________________________________________________________ U338EN-1. 2 Chapter 4 _______________________________________________________________ Installation 2 3 1 Figure 3 Electrical Connections of HMM212 Module The following numbers refer to Figure 3 above: 1 = During normal use, leave the jumper as indicated here (factory setting). 2 = Calibration connector for the HMI41 3 = Calibration jumper when not in use VAISALA _______________________________________________________________________ 19 USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 20 ____________________________________________________________________ U338EN-1. 2 Chapter 5 _______________________________________________________________ Calibration CHAPTER 5 CALIBRATION This chapter contains information that is needed to calibrate this product. Vaisala recommends a recalibration of the HMM212 module after six months of use. After the first recalibration, the recommended calibration interval is approximately 12 months. However, please note that these intervals depend on the operating conditions and the required accuracy. [. . . ] Note that during gain adjustment, the offset point does not change: Figure 6 Offset and Gain Calibration Examples NOTE After having performed the calibration, disconnect the jumper. 26 ____________________________________________________________________ U338EN-1. 2 Chapter 6 ______________________________________________________________ Maintenance CHAPTER 6 MAINTENANCE This chapter provides information that is needed in basic maintenance of the product. Replacing the HUMICAP®180R Sensor and the Filter Remove the damaged sensor and insert a new one. Handle the sensor by the plastic socket. Recalibrate the transmitter. CAUTION Do not touch the sensor element. Replace a dirty filter to ensure a maximum lifetime and a fast response for the sensor. Replacing Consumables This section describes how to replace consumables. Parts List for Consumables Table 6 Available Spare Parts Order Code HUMICAP180R HM46670 Spare Part HUMICAP®180R Sensor Stainless steel sintered filter VAISALA _______________________________________________________________________ 27 USER'S GUIDE____________________________________________________________________ This page intentionally left blank. 28 ____________________________________________________________________ U338EN-1. 2 Chapter 7 ___________________________________________________________ Troubleshooting CHAPTER 7 TROUBLESHOOTING This chapter describes common problems, their probable causes and remedies, and contact information for technical support. Troubleshooting Procedure When troubleshooting the product, write a problem report consisting of the following issues: - What failed (what worked / did not work)?- Where did it fail (location and environment)? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA HMM212

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA HMM212 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag