Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA HMP130. We hope that this VAISALA HMP130 user guide will be useful to you.
Lastmanuals help download the user guide VAISALA HMP130.
Manual abstract: user guide VAISALA HMP130WITH HMI41
Detailed instructions for use are in the User's Guide.
[. . . ] All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.
19165ZZ-U220en-1. 1
HMI41 Calibration Option Operating Manual
Contents
1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] To enter the setup mode, first press the ON/OFF button and the following appears:
RH T d T
% °C °F °C °F
P g/m hPa setminmax hyst hold Lo batHi
Then release the ON/OFF button and within 1. . . 2 seconds press both ENTER and MODE buttons until the following text appears on the display:
After a few seconds, the text changes automatically to show the following:
1996-08-29
1
HMI41 Calibration Option Operating Manual
19165ZZ-U220en-1. 1
°C
set
If the basic settings of the HMI41 (display units, automatic power off function, display quantities and pressure) have to be changed, please refer to the HMI41 Operating Manual. Otherwise, press ENTER repeatedly until the following text appears:
set
The number on the first line of the display corresponds to the following HMI41 functions: 1 = HMI41 as a humidity and temperature indicator 2 = HMI41 as a calibrator for HMD/W 60/70 and HMP140 series analogue transmitters 3 = HMI41 as a calibrator for HMP230 series digital transmitters 4 = HMI41 as a calibrator for the HMD/W20/30 and HMP130 series analogue transmitters To calibrate the HMD/W 20/30 or HMP130 series transmitters, select number 4 with buttons v (number up) and w (number down) and then turn the HMI41 off. When the HMI41 is turned on again, it will automatically assume the calibrator function for the HMD/W 20/30 and HMP130 series transmitters. If you wish to calibrate transmitters of some other type or use the HMI41 as an indicator, this selection has to be made accordingly; refer to corresponding manuals for further details.
2
1996-08-29
19165ZZ-U220en-1. 1
HMI41 Calibration Option Operating Manual
2.
CALIBRATION
For a successful calibration, it is essential that the probe of the HMI41 and that of the transmitter are at the same temperature, and that the reference probe has been previously calibrated. Always allow enough time for the readings to stabilize. Note that the stabilization time depends on the ambient conditions and may vary from 10 minutes to a couple of hours.
2. 1
Getting started After having selected the desired function (Chapter 1. 2), turn the HMI41 off and connect the calibration cable to the EXT connector at the bottom of the HMI41 (Figure 2. 1). Connect the other end of the cable to the appropriate connector in the transmitter (Figures 2. 2 - 2. 4).
MO DE
HOLD
ENTER
ON/OFF
EXT
Connector for the calibrati on cable
Figure 2. 1
Location of the HMI41 calibration connector
one point RH calibration
test connector
Figure 2. 2
Calibration connector and potentiometer in the HMP130 series transmitters
1996-08-29
3
HMI41 Calibration Option Operating Manual
19165ZZ-U220en-1. 1
test connector gain offset
Figure 2. 3
Calibration connector and potentiometers in the HMD 20/30UB/YB transmitters
gain offset
test connector
Figure 2. 4
Calibration connector and potentiometers in the HMW 20/30UB/YB transmitters
2. 2
Calibration After having connected the cable, turn the HMI41 on with the ON/OFF button and wait until a text similar to the following appears on the display:
RH %
Numbers on the first line indicate the RH measured by the transmitter, and numbers on the second line indicate the RH measured by the HMI41 reference probe. If you wish, you can now adjust the transmitter: · Wait until the readings have stabilized and adjust the calibration potentiometers (Figures 2. 2 - 2. 4) until the readings on the first and the second line are the same. It is recommended to use the offset potentiometer if the RH is <65 %RH and the gain potentiometer if the RH is >65 %RH.
4 1996-08-29
19165ZZ-U220en-1. 1
HMI41 Calibration Option Operating Manual
· After having completed the calibration, press ON/OFF and disconnect the cable. If you prefer, you can change the HMI41 display to show the difference in the readings and then adjust the transmitter. To do this, press MODE when both readings are on the display and a text similar to the following is displayed:
RH %
Numbers on the first line indicate how much the RH measured by transmitter differs from that of the reference probe. Numbers on the second line indicate the RH measured by the reference probe. [. . . ] select the HMI41 function: 1 = indicator 2 = calibrator for HMD/W 60/70 and HMP140 series analogue transmitters 3 = calibrator for HMP230 transmitters 4 = calibrator for HMD/W20/30 and HMP130 series transmitters
press ENTER repeatedly:
set
v (number up) or w (number down) ON/OFF
1996-08-26
1
HMI41 Calibration Option Appendix 1
19165ZZ-U220en-1. 1
2.
Calibration After having connected the cable, turn the HMI41 on and follow the instructions of the table below:
DISPLAY
RH Td T % °C°F °C°F
WHAT TO DO
PRESS:
The HMI41 has been turned on.
Pabs g/m Pa setminmax hyst hold Lo batHi
Indication of the software version (if the version is 1. 02 or more)
Indication of the battery voltage.
bat Hi
RH
%
RH
%
Let the readings stabilize and then adjust the transmitter potentiometers until the readings are the same. offset: <65 %RH gain : >65 %RH Alternatively, you can adjust the transmitter when the display shows the difference in readings. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA HMP130
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA HMP130 will begin.