User manual VAISALA HMP140 WITH HMI41
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA HMP140. We hope that this VAISALA HMP140 user guide will be useful to you.
Lastmanuals help download the user guide VAISALA HMP140.
Manual abstract: user guide VAISALA HMP140WITH HMI41
Detailed instructions for use are in the User's Guide.
[. . . ] USER'S GUIDE
Calibration of Series HMD/W60/70 and HMP140 Transmitters with Vaisala HUMICAP® Indicator HMI41
U218EN11
PUBLISHED BY Vaisala Oyj P. O. Box 26 FIN-00421 Helsinki Finland Phone (int. ): +358 9 8949 1 Fax: +358 9 8949 2227
Visit our Internet pages at http://www. vaisala. com/ © Vaisala 2006 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice.
Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.
19116ZZ-U218en-1. 1
HMI41 Calibration Option Operating Manual
Contents
1. [. . . ] They indicate the voltage range of the transmitter's RH channel (jumper selectable) currently stored in the HMI41 memory. Please, consult Figures 2. 3. 1 - 2. 3. 2 when checking the transmitter's jumper positions.
RH output selections 0. . . 1V 0. . . 5 V 0. . . 10 V
Figure 2. 3. 1
Jumper selections of the HMD/W70
RH output selections
0. . . 1V 0. . . 5 V
0. . . 10 V
Figure 2. 3. 2
Jumper selections of the HMP140
Numbers on the second line are blinking, and you can now select the range with buttons v or w according to the transmitter's jumper position. Please, consult Figures 2. 3. 3 - 2. 3. 4 when checking the transmitter's jumper positions.
T output selections 0. . . 1V 0. . . 5 V 0. . . 10 V
Figure 2. 3. 3
Jumper selections for the HMD/W70
T output selections 0. . . 1V 0. . . 5 V 0. . . 10 V
Figure 2. 3. 4
Jumper selections for the HMP140
You can now set the range with buttons v or w to correspond to the jumper position. A text similar to the following is displayed:
T set Lo
Numbers on the second line are blinking. They indicate the lower limit of the transmitter's voltage range currently stored in the HMI41 memory. Text in the lower righthand corner is Lo. You can now set the lower limit with buttons v or w to correspond to that of the transmitter. A text similar to the following is displayed:
1996-08-29
9
HMI41 Calibration Option Operating Manual
19116ZZ-U218en-1. 1
T set Hi
Numbers on the first line start to blink. They indicate the upper limit of the transmitter's voltage range currently stored in the HMI41 memory. Text in the lower righthand corner is Hi. You can now set the upper limit with buttons v or w to correspond to that of the transmitter. A text similar to the following is displayed:
T T set
°C °C Lo
Numbers on the second line are blinking. They indicate the lower limit of the transmitter's temperature range currently stored in the HMI41 memory. Text in the lower righthand corner is Lo. You can now set the lower limit to correspond to that of the transmitter. Set the limit with buttons v or w and acknowledge the setting with ENTER:
T T set Hi
°C °C
Numbers on the first line start to blink. They indicate the upper limit of the transmitter's temperature range currently stored in the HMI41 memory. Text in the lower righthand corner is Hi. You can now set the upper limit to correspond to that of the transmitter. Set the limit with buttons v or w and acknowledge the setting with ENTER. Turn the HMI41 off with the ON/OFF button. You can now calibrate the transmitter (see Chapter 3). [. . . ] If you wish, you can now adjust the transmitter (by pressing the MODE button you will return to the RH calibration mode): · Wait until the readings have stabilized and then adjust the calibration potentiometer (Figures 3. 2 - 3. 4) until the readings on the first and the second line are the same. It is recommended to use the offset potentiometer. · After having completed the calibration, press ON/OFF and disconnect the cable.
16
1996-08-29
19116ZZ-U218en-1. 1
HMI41 Calibration Option Operating Manual
If you press the HOLD button in the first T calibration mode, you will go on to the second T calibration mode which is an alternative for the first one. A text similar to the following is displayed:
T T
°C °C
Numbers on the first line indicate how much the temperature measured by the transmitter differs from that measured by the HMI41 reference probe. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA HMP140 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA HMP140 will begin.