User manual VAISALA HMP155

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA HMP155. We hope that this VAISALA HMP155 user guide will be useful to you.

Lastmanuals help download the user guide VAISALA HMP155.


Mode d'emploi VAISALA HMP155
Download

You may also download the following manuals related to this product:

   VAISALA HMP155 DATASHEET (418 ko)
   VAISALA HMP155 QUICK REFERENCE GUIDE (343 ko)

Manual abstract: user guide VAISALA HMP155

Detailed instructions for use are in the User's Guide.

[. . . ] USER'S GUIDE Vaisala HUMICAP® Humidity and Temperature Probe HMP155 M210912EN-B PUBLISHED BY Vaisala Oyj P. O. Box 26 FIN-00421 Helsinki Finland Phone (int. ): +358 9 8949 1 Fax: +358 9 8949 2227 Visit our Internet pages at http://www. vaisala. com/ © Vaisala 2009 No part of this manual may be reproduced in any form or by any means, electronic or mechanical (including photocopying), nor may its contents be communicated to a third party without prior written permission of the copyright holder. The contents are subject to change without prior notice. Please observe that this manual does not create any legally binding obligations for Vaisala towards the customer or end user. All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale. ________________________________________________________________________________ Table of Contents CHAPTER 1 GENERAL INFORMATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The settings can be changed one parameter at a time or all parameters at once. Example: Changing all parameters >seri 9600 e 7 1 Baud P D S : 9600 E 7 1 > Example: Changing baud only >seri 4800 Baud P D S > : 4800 E 7 1 SMODE Use the SMODE command to set the user port to permanent STOP, RUN, POLL or SEND mode. SMODE [xxxx] where xxxx = STOP, RUN, POLL or SEND VAISALA _______________________________________________________________________ 35 User's Guide ______________________________________________________________________ Example: >smode Serial mode > : STOP ?POLL Table 13 Mode STOP RUN POLL Selection of Output Modes Output Only with the SEND command Automatic output Only with the SEND [addr] command Available Commands All (default mode) Only command S Use with RS-485 buses Selected output mode will be activated after power outages. INTV Use the INTV command to set the outputting interval for the RUN mode. The default value for this command is 2 seconds. INTV [xxx yyy] where xxx = yyy = Output interval (0. . . 255) where 0 is the fastest possible output rate. Unit (s, min or h) Example: >intv 1 min Interval > : 1 min 36 __________________________________________________________________ M210912EN-B Chapter 4 ________________________________________________________________ Operation Data Filtering The commands introduced in this section are used for setting the filtering level, checking the probe configuration, listing available commands and possible error messages, and displaying the software information of the probe. FILT [0. 1. . . 1] Use the FILT [xxx] serial line command to set the filtering level. The output is calculated based on the following formula: [( new result * filt) + ( old result * (1. 0 - filt))]. FILT [xxx] where xxx = 0. 1. . . 1 where 1. 0 = no filter and 0. 1 = about 16 moving average Example: >filt Filter > : 0. 800 ? ? Use the ?serial line command to check the current probe configuration. command is similar but can also be used if the probe is in POLL mode. VAISALA _______________________________________________________________________ 37 User's Guide ______________________________________________________________________ Example: >?HMP155 1. 00 Serial number : Batch number : Module number : Sensor number : Sensor model : Cal. info : Time : Serial mode : Baud P D S : Output interval: Serial delay : Address : Pressure : Filter : Ch0 output : Ch1 output : Ch0 error out : Ch1 error out : Ch0 RH lo : Ch0 RH hi : Ch1 T lo : Ch1 T hi : > C1230001 B2350090 C4840248 B4250001 Humicap 180 YYYYMMDD NONE 00:01:06 STOP 4800 E 7 1 2S 0 0 1. 013 bar 0. 800 0 . . . 1 V 0. 00 V 0. 00 V 0. 00 %RH 100. 00 %RH -40. 00 'C 60. 00 'C 38 __________________________________________________________________ M210912EN-B Chapter 4 ________________________________________________________________ Operation HELP Use the HELP command to list the available commands. ACAL ch0/ch1 ADDR 0. . . 99 AERR err1 err2 AMODE ch1 ch2 ASEL quantity1 quantity2 low1 high1 low2 high2 ATEST value1 value2 CDATE 'cal. date' CLOSE CRH CT CTA CTEXT 'cal. info' ERRS FCRH FILT value FORM 'format string' HELP INTV 0. . . 255 s/min/h L LI OPEN addr PRES bar PUR on/off R RESET S SDELAY 0. . . 255 SEND addr SERI baud p d s SMODE stop/run/poll TIME hh:mm:ss UNIT m/n VERS XHEAT on/off XPRES bar > VAISALA _______________________________________________________________________ 39 User's Guide ______________________________________________________________________ ERRS Use the ERRS command to display probe error messages, see Table 14 on page 54. Example: >errs No errors > VERS Use the VERS command to display software version information. Example: >vers HMP155 1. 01 > Resetting Transmitter Using Serial Line RESET Use the RESET command to reset the device. The user port switches to start-up output mode selected with SMODE command. Example: >reset HMP155 1. 00 > 40 __________________________________________________________________ M210912EN-B Chapter 4 ________________________________________________________________ Operation Formatting Analog Output In this section, the commands for formatting the analog output settings are introduced. Analog Output Settings The two analog outputs are set in the factory according to the order form. In case you want to change the settings, follow these instructions. NOTE The serial line commands AMODE, ASEL and ATEST cannot be used with the passive output version of HMP155. AMODE Use the serial line to select and scale the analog output quantities. Connect the probe to the PC and then open the terminal connection between your PC and the probe. The probe needs to be in ADJUST mode for the AMODE command to work. [. . . ] Turn MI70 on by pressing the power key and follow the instructions given on the display. 68 __________________________________________________________________ M210912EN-B Chapter 6 ___________________________________________________Calibration and Adjustment NOTE When turning on the passive output version, always hold down the ADJ button simultaneously. 3. Activate the adjustment mode by holding down the ADJ button on the probe until the message below appears on the MI70 display. 4. Press OK to move on to the adjustment and select the quantity you want to adjust. The list of quantities displayed in the figure below vary according to the configuration of your HMP155. 5. Follow the instructions given on the display to finish the adjustment. VAISALA _______________________________________________________________________ 69 User's Guide ______________________________________________________________________ This page intentionally left blank. 70 __________________________________________________________________ M210912EN-B Chapter 7 ____________________________________________________________ Technical Data CHAPTER 7 TECHNICAL DATA This chapter provides the technical data of the product. Performance Relative Humidity Measurement range 0 . . . 100 %RH Accuracy (including non-linearity, hysteresis and repeatability) at +15 . . . 104 °F) ± (1. 0 + 0. 008 × reading) % RH at -40 . . . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA HMP155

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA HMP155 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag