Manual abstract: user guide VAISALA PMB100
Detailed instructions for use are in the User's Guide.
[. . . ] All legally binding commitments and agreements are included exclusively in the applicable supply contract or Conditions of Sale.
CHAPTER 1_______________________________________________________ GENERAL INFORMATION
Table of contents
CHAPTER 1
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 2
PRODUCT DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 BAROCAP® pressure sensor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CHAPTER 3
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Dimensions in mm (in inches). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Pressure calculations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Offset/Gain corrections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
CHAPTER 4
TECHNICAL DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Operating range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Accuracy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
APPENDIX A
READING COEFFICIENTS FROM THE EEPROM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
VAISALA __________________________________________________________________________ 3
USER'S GUIDE_______________________________________________________________________
CHAPTER 1
GENERAL INFORMATION
Safety
Throughout the manual, important safety considerations are highlighted as follows:
WARNING
Warning denotes a serious hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in injury to or death of personnel.
CAUTION
Caution denotes a hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the product.
NOTE
Note highlights important information. [. . . ] The thinner piece of silicon is electrostatically bonded to the glass surface to form a strong and hermetic bond. Thin film metallization has been deposited to form a capacitor electrode inside the vacuum reference chamber; the other electrode is the pressure sensitive silicon diaphragm. The coefficients of thermal expansion of silicon and glass materials used in the BAROCAP® pressure sensor are carefully matched together in order to minimize the temperature dependence and to maximize the long-term stability. The BAROCAP® pressure sensor is designed to achieve zero temperature dependence at 1000 hPa and its long-term stability has been maximized by thermal ageing at an elevated temperature. The BAROCAP® capacitive pressure sensor features a wide dynamic range and no self-heating effect. The excellent hysteresis and repeatability characteristics are based on the ideal spring characteristics of single crystal silicon. In the BAROCAP® pressure sensor, the silicon material is exerted to only few percent of its whole elastic range.
6 ____________________________________________________________________ M010035EN-A
CHAPTER 3________________________________________________________________ OPERATION
CHAPTER 3
OPERATION
Connections
The pin assignments of the PMB100 module are according to Figure 2. Connect 8. . . 16 VDC supply voltage (typically 2 mA) to the pin VDC and the ground plane directly to the pin GND. The output signal (0. . . 2. 5 VDC) is measured from the pin OUT and the reference signal (2. 5 VDC ± 2%) from the pin REF. If the coefficients are read from the EEPROM, the pin +5 V, SCL and SDA are also connected. The +5 V-pin is used for supply voltage of the EEPROM. The pins SCL and SDA are for data transfer between the EEPROM and a microprocessor. Temperature of the module is measured with an external T sensor, which should be placed as close to the module as possible. The module can also be switched to shut down mode by using a TTL level trigger on the pin SH. A signal 0. 7 V or lower activates and a signal higher than 2 V switches the module off.
REF SH
Out VDC GND + 5V SCL SDA
Figure 2
Pin assignments
VAISALA __________________________________________________________________________ 7
USER'S GUIDE_______________________________________________________________________
In applications where adverse electromagnetic fields exist, an additional EMI protection may be necessary. In Figure 3, there is an example of an electromagnetic interference protection of the PMB100 module. The EMI filters should be placed as close to the pins as possible.
GND directly connected to ground plane
+
filter filter
PMB100 module
GND VDC OUT REF
filter
Power regulator
-
Vout
Copper pour connected to ground.
Vref
Vout VDC GND Vref
Figure 3
Electromagnetic interference protection of the PMB100. Filters, for example, T-type EMI suppression filters with capacitance of 47pF (like Murata, DSS310-55Y5S470M100). [. . . ] +45°C < 80%RH ±0. 25 hPa ±0. 05 hPa ±0. 05 hPa ±0. 3 hPa ±0. 3 hPa ±0. 5 hPa
Accuracy
Linearity Pressure hysteresis Repeatability Accuracy at +20°C Temperature hysteresis Accuracy (-5°C . . . 45°C)
Total accuracy after the OFFSET correction (+20 °C, 1000 hPa) performed by the user is obtained by using the following equation: Total accuracy = ± 0. 5 2 + n 2 hPa where n is the calibration uncertainty Without the OFFSET correction performed by the user: Total accuracy (-5 . . . +45 °C)±1. 00 hPa Long-term stability Effect of thermal or mechanical shocks ±0. 20 hPa/year (typical) <0. 20 hPa (5)
An error of 1 °C in temperature measurement causes an error of 0. 14 hPa in pressure.
General
Supply voltage range 9. . . 16 VDC Shutdown control with TTL level trigger <0. 7 V module ON >2. 0 V module OFF Supply voltage sensitivity less than 0. 1 hPa
VAISALA _________________________________________________________________________ 11
USER'S GUIDE_______________________________________________________________________
Current consumption operation mode shutdown mode Output voltage output reference Resolution Load resistance Load capacitance Settling time at power-up Response time Warm-up shift Pressure hose Maximum pressure limit Electrical connectors Weight
2 mA (typical) 150 µA (typical) 0. . . 2. 5 V 2. 5 V ±2% (type LM4431M3) 0. 1 hPa 10 k minimum 100 nF maximun 200 ms 100 ms less than 0. 05 hPa 1/16'' id 1/8'' OD, vinyl hose 300mm 2000 hPa two 6-pin pin headers, 2. 54 mm grid 70 g
12 ___________________________________________________________________ M010035EN-A
APPENDIX A _______________________________________ READING COEFFICIENTS FROM THE EEPROM
APPENDIX A
READING COEFFICIENTS FROM THE EEPROM
The PMB100 module has a Xicor's EEPROM memory, type X24C02, which uses the I2C interface. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA PMB100
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.