Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VAISALA RSA922. We hope that this VAISALA RSA922 user guide will be useful to you.
Lastmanuals help download the user guide VAISALA RSA922.
Manual abstract: user guide VAISALA RSA922DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] www. vaisala. com
Vaisala Ozone Interface Kit RSA922
Features / Benefits
Built around Vaisala Digital Interface OIF92 Four-channel digital interface for connecting digital Vaisala Radiosonde RS92 models to Brewer-Mast type ozone sensor for ozone sounding Enables accurate measurements, sharp vertical resolution and a fast sampling rate Can be used for 1-2 other sensor measurements within specified ranges
The Vaisala Ozone Interface Kit RSA922, featuring the Vaisala Digital Interface OIF92, is used for ozone sounding with the digital versions of the Vaisala Radiosonde RS92 and the MAST corporation 730-10 Brewer-Mast type ozone sensor. [. . . ] It is easy to perform simulations and post-ascent processing with the METGRAPH module of the DigiCORA® Sounding Software. System maintenance can be performed by Vaisala under the terms of a Vaisala Service Contract.
Technical data
Digital Interface OIF92
MAST Corporation 730-10 ozone sensor (Brewer-Mast type) Dimensions 40 (l) x 35 (w) mm Cable length 380 mm Weight with cable Max. 20 g Number of analog input channels 4 Analog-to-digital converter resolution 16-bit Measurement temperature range for all channels -5 . . . +60 °C Operating temperature range for all channels - 40 . . . +85 °C Sampling rate for all channels Dependent upon the radiosonde: e. g. once per second with the RS92-SGP Synchronization All channels are measured in synchronization with the meteorological measurements (pressure, temperature, humidity, wind) Ozone current measurement range 0 . . . 20 µA For use with Ozone current measurement uncertainty *) 0. 05% of the reading, minimum 1 nA Accuracy examples: for 5 µA measurement the accuracy is 2. 5 nA for 10 µA measurement the accuracy is 5 nA for 20 µA measurement the accuracy is 10 nA Resolution 1 nA (LSB = 0. 35 nA) Typical noise 1 nA (standard deviation) Ozone temperature measurement range -5 . . . +60 °C Temperature measurement uncertainty*) ±0. 2 °C Temperature resolution 0. 01 °C Typical noise 0. 015 °C (standard deviation) Voltage measurement range (both voltage channels) 0 . . . [. . . ] All specifications -- technical included -- are subject to change without notice. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VAISALA RSA922
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VAISALA RSA922 will begin.