User manual VALEX SP-9217

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VALEX SP-9217. We hope that this VALEX SP-9217 user guide will be useful to you.

Lastmanuals help download the user guide VALEX SP-9217.


Mode d'emploi VALEX SP-9217
Download
Manual abstract: user guide VALEX SP-9217

Detailed instructions for use are in the User's Guide.

[. . . ] 6 Revision Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 This document is presented by Valex Corp. for general information purposes and may be reproduced in part or total. [. . . ] Per brochure ± . 25" (± 6. 35mm) None SP-9217 Rev. W, Page 2 of 8 4. 0 Operating Data: Temperature Range: -20°F to 350°F as dictated by standard seat/seal materials. Seat/seal materials other than standard may affect the working temperature range. Maximum Working Pressure: Temp (F) 1/4" 1" 15A 20 1000 0 1200 1000 100 1000 350 1100 0 11/2" 2" 20A 40A 800 800 800 0 Pressure (PSIG) 21/2" 4" 50A 80A 500 500 500 0 4. 5" 6" Maximum Working Pressure 100A (PTFE Seats / Seals ) 400 400 400 0 300 300 300 0 6" 100A 21/2" 4" (50A 80A) 11/2" 2" (20A 40A) 1/4" 1" (15A) 1000 900 800 Pressure (PSIG) 700 600 500 400 300 200 100 0 50 0 50 100 150 200 250 300 350 400 Temperature (°F) Flow Coefficient Data: Valve Size 1/4" X . 035" 3/8" X . 035" 1/2" X. 049" 3/4" X. 065" 1" X. 065" 1-1/2" X. 065" 2" X. 065" 2-1/2" X. 065" 3" X. 065" 4" X. 083" 6" X. 109" JIS 15A (5S) JIS 20A (5S) JIS 25A (5S) JIS 32A (5S) JIS 40A (5S) JIS 50A (5S) JIS 65A (5S) JIS 80A (5S) JIS 100A (5S) 1) Ball Orifice (Inches) 0. 402 0. 402 0. 402 0. 620 0. 870 1. 370 1. 870 2. 370 2. 870 3. 834 5. 782 0. 870 1. 370 1. 370 1. 870 1. 870 2. 370 2. 870 3. 834 4. 335 Connection Orifice (Inches) 0. 180 0. 305 0. 402 0. 620 0. 870 1. 370 1. 870 2. 370 2. 870 3. 834 5. 782 0. 724 0. 941 1. 209 1. 551 1. 783 2. 252 2. 839 3. 343 4. 335 Cv 1 2. 9 9. 0 16. 3 41. 2 84. 9 223. 3 432. 3 714. 4 1071. 2 1975. 3 4697. 8 57. 4 100. 4 171. 1 290. 7 391. 0 641. 1 1046. 5 1478. 4 2559. 3 Flow coefficient data calculated using methods described in Crane Technical Paper TP-410. SP-9217 Rev. W, Page 3 of 8 5. 0 Final Process: General: Neither ozone-depleting nor mercury-bearing compounds are used during the Valex processing or testing of any product. Class 100 per Federal Standard 209E and ISO 14644. Clean-Room Certification: Component Cleaning (prior to assembly): Component Drying: (prior to assembly): Final Assembly: 6. 0 Testing and Inspection: Visual Inspection: DI water. Nitrogen flow. Pre-cleaned components are assembled in a Class 100 cleanroom. Inspected for i. d. /o. d. defects and face quality as compared to the visual workmanship standards set by the Valex Library of Parts for this product line. surfaces are inspected under ultraviolet light for absence of hydrocarbon fluorescence using a clean, lint-free cloth per CGA G-4. 1. The same cloth is then evaluated under a white light for cleanliness against visual workmanship standards for this product line. Surface Roughness Measurement: Flow path i. d. surfaces are measured with a stylus-type measuring device in accordance with ASME B46. 1 for conformance to the roughness as specified in sections 3. 0 and 9. 0. Assemblies are inspected for conformance to tolerances specified in this specification. Assembled valves are leak tested at Valex to 1 x 10-6 atm·cc/sec. Leak tests are performed using 99. 995% helium. Assembled valves are tested in a Class 100 environment. Note: Valex does not guarantee leak rates for valves rebuilt outside Valex facilities. Dimensional Inspection: Leak Test: Body Pressure Test: Valve bodies are hydrostatically pressure tested to 1. 5 times the working pressure given in section 4. 0 per 0. 4 AQL sampling. 7. 0 Packaging: Capping: Face-Seal Purge Port: Nickel gasket with metal threaded cap. Compression purge port: Standard Option: Vinyl cap over metal threaded nut. 1/4" to 4" (6. 4mm to 101. 6mm) Tube Stub: Polyethylene cap over a polyamide film. JIS 15A to 100A (21. 7mm to 114. 3mm) Pipe Stub: Polyethylene cap over a polyamide film. SP-9217 Rev. [. . . ] - All other features same as "E" above - Assembled with Oxygen-compatible lube - All other features same as "E" above. - Assembled with Oxygen-compatible lube - All other features same as "N" above. N: L: P: SP-9217 Rev. W, Page 5 of 8 10. 0 Ordering Part Number System: NOTE: Not all possible part number combinations are available. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VALEX SP-9217

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VALEX SP-9217 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag