User manual VALEX SP9217X DATASHEET REV X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VALEX SP9217X. We hope that this VALEX SP9217X user guide will be useful to you.

Lastmanuals help download the user guide VALEX SP9217X.


Mode d'emploi VALEX SP9217X
Download
Manual abstract: user guide VALEX SP9217XDATASHEET REV X

Detailed instructions for use are in the User's Guide.

[. . . ] X, Page 1 of 8 1. 0 Scope: Configuration: Sizes: Ball valve. to 152. 4mm o. d. ) JIS 15A to 100A pipe (21. 7mm o. d. to 114. 3mm o. d. ) 2. 0 Reference Documents: General Note: All specification references shall be taken as the latest editions, including appendices, addenda, errata, and revisions. [. . . ] X, Page 3 of 8 5. 0 Final Process: General: Neither ozone-depleting nor mercury-bearing compounds are used during the Valex processing or testing of any product. Class 100 per Federal Standard 209E and ISO 14644. Clean-Room Certification: Component Cleaning (prior to assembly): Component Drying: (prior to assembly): Final Assembly: 6. 0 Testing and Inspection: Visual Inspection: DI water. Nitrogen flow. Pre-cleaned components are assembled in a Class 100 cleanroom. Inspected for i. d. /o. d. defects and face quality as compared to the visual workmanship standards set by the Valex Library of Parts for this product line. surfaces are inspected under ultraviolet light for absence of hydrocarbon fluorescence using a clean, lint-free cloth per CGA G-4. 1. The same cloth is then evaluated under a white light for cleanliness against visual workmanship standards for this product line. Surface Roughness Measurement: Flow path i. d. surfaces are measured with a stylus-type measuring device in accordance with ASME B46. 1 for conformance to the roughness as specified in sections 3. 0 and 9. 0. Assemblies are inspected for conformance to tolerances specified in this specification. Assembled valves are leak tested at Valex to 1 x 10-6 atm·cc/sec. Leak tests are performed using 99. 995% helium. Assembled valves are tested in a Class 100 environment. Note: Valex does not guarantee leak rates for valves rebuilt outside Valex facilities. Dimensional Inspection: Leak Test: Body Pressure Test: Valve bodies are hydrostatically pressure tested to 1. 5 times the working pressure given in section 4. 0 per 0. 4 AQL sampling. 7. 0 Packaging: Capping: Face-Seal Purge Port: Nickel gasket with metal threaded cap. Compression purge port: Standard Option: Vinyl cap over metal threaded nut. 1/4" to 4" (6. 4mm to 101. 6mm) Tube Stub: Polyethylene cap over a polyamide film. JIS 15A to 100A (21. 7mm to 114. 3mm) Pipe Stub: Polyethylene cap over a polyamide film. SP-9217 Rev. X, Page 4 of 8 Bagging: Double-bagged in Nitrogen-purged polyethylene and heat-sealed in a Class 100 cleanroom. Packaged for shipment in a manner that prevents damage to product and primaryproduct packaging. Shipping Container: 8. 0 Marking and Documentation: Marking and Traceability: All components are traceable to the producing mill and heat number by a metalstamped code number. Each valve is pin-stamped with a Valex work-order i. d. [. . . ] Please contact Valex for availability. ASTM INCH SIZES S - SHC 32 M - 16 M X S - E B Material S = Stainless Steel Assembly Pattern STR = straight DHC = double horizontal cross SHC = single horizontal cross DHT = double horizontal tee DVT = double vertical tee DAV = double angle valve DSS = double single sided Main Tube Size 04 = 1/4" o. d. x . 109" wall Main Tube Connections C = compression fitting inlet and outlet F = face-seal fixed male inlet and outlet G = tube buttweld inlet, face-seal fixed male outlet H = compression fitting inlet, tube buttweld outlet J = tube buttweld inlet, compression fitting outlet K = face-seal fixed male inlet, tube buttweld outlet M = tube buttweld inlet and outlet Branch Valve(s) Outlet Size X X = no branch valve(s) 16 = 1" 04 = 1/4" 24 = 1-1/2" 06 = 3/8" 32 = 2" 08 = 1/2" (. 049w) 40 = 2-1/2" B8 = 1/2" (. 065w) 48 = 3" 12 = 3/4" 64 = 4" Handle Sleeve Color B = blue P = purple D = gold R = red G = green S = silver I = pink W = white K = black Y = yellow Section 9. 0 Identifier E = 10 Ra electropolished / no lube L = 10 Ra electropolished / oxygen-compatible lube M = 180grit or 25Ra / no lube N = 20 Ra mechanical polished / no lube P = 20 Ra mechanical polished / oxygen-compatible Outlet Purge Port* X = no purge port C = compression fitting D = purge drill (open to atmosphere) P = compression fitting w/ plug S = face seal (swivel male nut w/hex) T = purge tube (open to atmosphere) V = purge valve w/ compression fitting Inlet Purge Port* X = no purge port C = compression fitting D = purge drill (open to atmosphere) P = compression fitting w/ plug S = face seal (swivel male nut w/hex) T = purge tube (open to atmosphere) V = purge valve w/ compression fitting Connection On Branch Valve(s) X = no branch valve M = tube buttweld C = compression fitting F = face-seal fixed male N = tube buttweld w/expansion plate P = compression fitting w/ plug * Purge port sizes 1/4" purge port is used for valve sizes up to 2". 1/2" purge port is used for valve sizes larger than 2". SP-9217 Rev. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VALEX SP9217X

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VALEX SP9217X will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag