User manual VDO DEPTH SOUNDER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VDO DEPTH SOUNDER. We hope that this VDO DEPTH SOUNDER user guide will be useful to you.

Lastmanuals help download the user guide VDO DEPTH SOUNDER.


Mode d'emploi VDO DEPTH SOUNDER
Download

You may also download the following manuals related to this product:

   VDO DEPTH SOUNDER INSTALLATION (192 ko)

Manual abstract: user guide VDO DEPTH SOUNDER

Detailed instructions for use are in the User's Guide.

[. . . ] You should be familiar with all functions of the system to guarantee easy and safe use of your VDO depth sounder. Please take the time to study this manual completely. Your VDO Kienzle agent will be pleased to help you, if you have any further questions or problems. VDO Kienzle Vertrieb und Service GmbH © Copyright by VDO Kienzle Vertrieb und Service GmbH 1997. 27 SAFETY Safety Instructions Please respect all instructions of this manual . [. . . ] The pointer returns to zero. The acoustical alarm can be muted by activating the pushbutton. Check the connection of the indicating instrument to the echo sounder first. Defective contacts may have caused the alarm. If the alarm continues, although the connection is perfect, please contact your VDO agency. 32 BASIC CALIBRATION Basic calibration of the VDO Depth Sounder Selection of the unit Setting the keel depth Keep the pushbutton pressed and switch the indicating instrument power supply on. Wait until the display shows , , UNIT". Release the pushbutton. The current unit setting (feet in the example) is displayed. Push the button to toggle between the units feet and meter. About 5 seconds after unit selection the instrument prompts for the keel depth entry. The display shows , , OFFSET" and, shortly thereafter, the current keel depth setting (0. 0 in the example). os 0. 0 OFFSET = keel depth Push the button until the measured keel depth (1. 2 m in the example) is set. The value increments by 0. 1 m or 1 foot at each press of the button. Incrementing is automatic if you keep the pushbutton pressed. os 1. 2 The setting range is 0. 0 to 3. 0 m or 0 to 9 feet. The set value is stored if the pushbutton is not pressed for 5 seconds. After a double acknowledgement tone the depth is displayed automati33 BASIC CALIBRATION / ALARM cally. The unit now displays the water depth below keel (4. 6 m in the example). --4. 6 Setting and activating the shallow water alarm In unsafe depths and in waters with unknown depths the alarm will warn you in time to avoid shallows and to prevent boat damages. The alarm setting range is 0 m to 120 m (0 to 396 feet). The alarm can be switched off or on by double activation of the pushbutton when the display shows the current depth. The display shows the alarm threshold (0. 0 m in the example) when the alarm is switched on. Set the desired alarm threshold by pressing the pushbutton. Up to 10 m (32 feet) the value increments by 0. 1 m (1 foot), up to 120 m (396 feet) by 1. 0 m (3. . . 4 feet) per button activation. Continuous incrementation is obtained by keeping the pushbutton pressed. After about 5 seconds after setting of the alarm threshold (0. 9 m in the example) the display shows the current depth (2. 7 m in the example) , and the set value is stored. 2. 7 A continuous alarm is sounded if the depth below keel is less than the set alarm threshold (0. 9 m in the example), and the flashing display shows the current depth measurement (0. 7 m in the example). 0. 7 34 ALARM The acoustic alarm can be switched off by pressing the button. It stops automatically when the depth below keel is greater than the set threshold. The alarm function is deactivated if the button is quickly pushed twice when the current depth (2. 7 m in the example) is displayed. 2. 7 Push button Push button off 2. 7 35 TROUBLESHOOTING Troubleshooting Fault: - No depth sounder function Cause and correction: - Check electrical connections per wiring diagram. - No ground echo is received or evaluated correctly. - Check installation instructions for echo sounder. [. . . ] Never remove the sounder with the ship in the water. Never pull on the cable to remove the echo sounder. Insert the blind plug after removal of the echo sounder. The sounder can be covered with a thin coat of antifouling paint. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VDO DEPTH SOUNDER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VDO DEPTH SOUNDER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag