User manual VIESSMANN VITOLA 200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VIESSMANN VITOLA 200. We hope that this VIESSMANN VITOLA 200 user guide will be useful to you.

Lastmanuals help download the user guide VIESSMANN VITOLA 200.


Mode d'emploi VIESSMANN VITOLA 200
Download
Manual abstract: user guide VIESSMANN VITOLA 200

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Instructions for use by heating contractor Vitola 200 VB2 Series Oil-/Gas-Fired Boiler Heating input 83 to 300 MBH 24 to 88 kW VITOLA 200 IMPORTANT Read and save these instructions for future reference. 5167 404 v1. 9 01/2004 Safety, Installation and Warranty Requirements Safety, Installation and Warranty Requirements Please ensure that this manual is read and understood before commencing installation. Failure to comply with the issues listed below and details printed in this manual can cause product/property damage, severe personal injury, and/or loss of life. Ensure all requirements below are understood and fulfilled (including detailed information found in manual subsections). H Licensed professional heating contractor The installation, adjustment, service, and maintenance of this equipment must be performed by a licensed professional heating contractor. " H Contaminated air Air contaminated by chemicals can cause by-products in the combustion process which are poisonous to inhabitants and destructive to Viessmann equipment. " H Fresh air This equipment requires fresh air for safe operation and must be installed ensuring provisions for adequate combustion and ventilation air exist. Please see section entitled “Important Regulatory and Installation Requirements. ” For a listing of chemicals which cannot be stored in or near the boiler room, please see section entitled “Combustion Air Supply. ” " For information pertaining to the fresh air requirements of this product, please see section entitled “Combustion Air Supply. ” H Product documentation Read all applicable documentation before commencing installation. Store documentation near boiler in a readily accessible location for reference in the future by service personnel. " H Carbon monoxide Improper installation, adjustment, service and/or maintenance can cause flue products to flow into living space. [. . . ] The boiler should be located as close to the chimney as possible. The vent connection must be made in the shortest possible way with minimum elbows. If necessary, rearrange existing water piping to achieve closest chimney connection. Avoid long horizontal runs of vent pipe. Horizontal runs must be supported by appropriate means to prevent sagging. Horizontal runs must have not less than ¼” rise per ft. Metal strapping must be used to support horizontal runs every 4 ft. Ensure the weight of the vent pipe is not supported by the boiler. Insulate vent pipe to reduce cooling of flue gas. Terminate venting system outside with approved termination at least six feet above boiler. Vent pipe must extend at least three feet above the point where it passes through the roof. Vent termination must be at least two feet higher than any portion of the building within ten feet horizontal, and vent termination must be at least two feet higher than roof peaks within ten feet horizontal. Down draft and condensation problems must be corrected (see page 31). H After it has been determined that each appliance remaining connected to the common venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas burning appliance to their previous condition of use. H Any improper operation of the common venting system should be corrected so the installation conforms with the National Fuel Gas Code, ANSI Z223. 1 latest edition. When resizing, any portion of the common venting system should be resized to approach the minimum size as determined using the appropriate tables in the CSA B149. 1 or . 2 National Fuel Gas Code (Canada), or ANSI Z223. 1 latest edition (USA). WARNING Improper sizing, maintenance, termination of vent or chimney can cause flue gases to enter living space. Any blockage of vent or chimney by birds’ nests, ice, snow, debris, or other materials can cause flue gases to enter living space. Flue gases entering living space can cause carbon monoxide poisoning which can result in severe personal injury or loss of life. WARNING Installers must follow local regulations with respect to installation of carbon monoxide detectors. Follow manufacturer’s maintenance schedule of boiler. Chimney liner A corrosion-resistant approved liner must be installed in masonry or unlined chimneys. The liner should be insulated to prevent condensation of flue gas in cold weather. 5167 404 v1. 9 Connections Venting Connection (Oil Installations) Oil installations The vent system must comply with all applicable local and/or national codes. If installing boiler with a wall vent system, ensure all manufacturer’s requirements are met. Installation of boiler venting The heating contractor shall ensure all of the following requirements are met: H The vent system shall ensure that no hazard is created by the products of combustion. H Provision shall be made to vent the products of combustion safely to outside the building, and such venting shall not pass through or be installed in return air, supply air, ventilating, or combustion air ducts or shafts. [. . . ] sensor cables) through cable opening toward boiler control. Coil excess cabling and tuck between side panel and insulation. Tighten strain reliefs. CAUTION Always route all cables and capillaries between nylon-backed insulation and metal enclosure panels. Never allow cables and capillaries to come in direct contact with metal pressure vessel! 5167 404 v1. 9 29 Connections Top Panel Installation 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VIESSMANN VITOLA 200

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VIESSMANN VITOLA 200 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag