If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VISONIC DISCOVERY K9-80 MCW. We hope that this VISONIC DISCOVERY K9-80 MCW user guide will be useful to you.

Lastmanuals help download the user guide VISONIC DISCOVERY K9-80 MCW.


Mode d'emploi VISONIC DISCOVERY K9-80 MCW
Download
Manual abstract: user guide VISONIC DISCOVERY K9-80 MCWINSTALLER GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] DISCOVERY K9-80 MCW Wireless PowerCode PIR Detector 1. FEATURES · Uses TSITM (Target Specific Imaging) technology for distinction between humans and pets · Immunity to pets weighing up to 36 kg (80 lb) · Includes a fully supervised PowerCode transmitter · Patented sophisticated motion analysis algorithm - True Motion Recognition (TMRTM) · Three-position vertical adjustment scale · Integral swivel bracket for wall or ceiling installation · Programmable motion event counter - ON (default) or OFF · Front tamper switch · Back tamper switch (option) · Full stabilization achieved 30 seconds after power up · After detection, the detector disables itself to save battery power. It reverts to the ready state if there is no subsequent detection throughout the following 2-minute period · An optional version provides better protection for systems compliant with DD243. After initial detection, the detector is capable of 6 additional detections for a period of 5 minutes. [. . . ] Loosen the vertical adjustment screw, slide the PCB down and remove it via the "keyhole" (see Figure 4). Rotate the bracket to the desired position (see Figure 7) but do not yet tighten the screw fully. 2 DE3638 Note: At power up or reset, the LED flashes for 30 seconds regardless of the jumper position and then enters walk-test mode. After 15 minutes the detector enters normal mode in which the LED functions according to the LED control jumper position. 3. 8 Vertical Adjustment Figure 7. Wall and Ceiling Positions of Bracket F. Mark the points for drilling through the two mounting holes of the bracket. Attach the bracket to the mounting surface. Tilt down or swivel the detector to face the desired direction. Figure 8 shows the tilt/swivel possibilities. A. Pet-Immune Applications To maintain maximum coverage range and pet immunity, the vertical adjustment scale must be adjusted in accordance with the actual mounting height (refer to Figure 10). Loosen the vertical adjustment screw and slide the printed circuit board up or down until the pointer shows the actual mounting height on the scale. When done, re-tighten the screw well. Figure 10. Pet-Free Locations To obtain the best coverage possible where no pets are present, mount the detector with the integral bracket at any desired height between 1. 8 m (6 ft) and 2. 4 m (8 ft). Then set the vertical adjustment scale to the 2. 4 m (8 ft) position and tilt the detector 20° down. Figure 8. Tilt/Swivel Limits 3. 6 Setting the Motion Event Counter The location of the motion event jumper is shown in Figure 4. Refer to Figure 9 below and mount the jumper as desired. 3. 9 Walk Testing Figure 9. Motion Event Counter Setting Options 3. 7 Setting the LED Control Jumper ON Position: Setting the jumper as shown enables the LED. Remember that the detector disables itself for 2-minutes after detection!OFF Position: Setting the jumper as shown disables the LED. Upon battery insertion or closing of the cover (which results in closing of the tamper switch) the detector goes into walk-test mode and automatically exits the mode after 15 minutes. Set the motion event counter as required (see Paragraph 3. 6). Adjust the vertical angle as desired (see Paragraph 3. 8). Remount the cover and fasten the case closure screw. This results in the resetting of the detector and the start of walktest mode. [. . . ] To exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid and insured. All freight and insurance costs are the responsibility of the Purchaser and are not included in this Warranty. This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of this warranty. This warranty shall apply to the Product only. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VISONIC DISCOVERY K9-80 MCW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VISONIC DISCOVERY K9-80 MCW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag