If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VISONIC POWERMAXCOMPLETE PANEL. We hope that this VISONIC POWERMAXCOMPLETE PANEL user guide will be useful to you.
Lastmanuals help download the user guide VISONIC POWERMAXCOMPLETE PANEL.
Manual abstract: user guide VISONIC POWERMAXCOMPLETE PANELQUICK GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] 7 - MCT-320 INSTALLATION
Magnet
2
Push catch and remove board
3
Insert battery
Front Tamper switch
Back Tamper switch (option)
Remove spacer
1
3mm spacer A. Fasten the spacer to mounting surface with 2 screws. Locate the magnet on the spacer at the correct direction and push it upward.
2
1
Release screw and remove cover
4
Mounting
Note It is highly recommended to attach the transmitter to the top of the door/window on the fixed frame and the magnet to the movable part (door or window). Make sure that the magnet is located not more than 6 mm (0. 25 in. ) from the transmitter's marked side.
Fig. [. . . ] DEFINE PANEL 01: ENTRY DELAY 1 03: EXIT DELAY EXIT DELAY 60 S
*
03: EXIT DELAY
10. 8) Press Press Press Select delay with and press 3 times
Resultant Display 4. DEFINE PANEL 01: ENTRY DELAY 1 Entry dly1 30 s
*
01: ENTRY DELAY 1 02: ENTRY DELAY 2 Entry dly2 60 s
**
6. 8.
Press Press Select delay with and press
02: ENTRY DELAY 2
* The default ENTRY DELAY 1 time is 30 S. ** The default ENTRY DELAY 2 time is 60 S.
6
D-302887
11. SETUP FOR GPRS/BB NO PHONE LINE (STEP 1)
DO NOT make any program changes in "DEFINE COM" other than those shown on this instructions unless necessary. Before continuing, remove power (AC and battery) and install a SIM card provisioned for GPRS data service. Request a SIM card phone number from your SIM supplier if you wish to have the ability to ARM / DISARM via text messaging or program from the central station receiver.
Action(s) 1. 9.
Press Press 3 times once
Resultant Display INSTALLER MODE ENTER CODE 1. 1:PSTN/GSM 2:GPRS/BB GPRS REPORT disable enable GPRS REPORT GPRS APN
Enter installer code (9999 by default)
Press Press Press Press Press Press 4 times once once once once once twice 3 times once
10. Enter Access Point Name
airnet1
Example: Seaguard SIM = airnet1 (Key #8 = scroll symbols up, Key #2 = scroll symbols down) (Key #5 = Toggle Uppercase / Lowercase)
14. Press
twice once once
GPRS APN <OK> TO EXIT READY 12:00PM
D-302887
7
12. REPORTING NO PHONE LINE (STEP 2)
Action(s) 1. 9.
Press Press 3 times once
Resultant Display INSTALLER MODE ENTER CODE 1. REPORTING REPORT EVENTS 1ST RPRT METHOD disable cellular cellular 1ST RPRT METHOD IP RCVR 1 000. 000. 000. 000 069. 074. 192. 027 IP RCVR 1 IP RCVR 2 000. 000. 000. 000 208. 017. 225. 027 IP RCVR 2 LINE FAIL REPORT PSTN 5 minutes don't report don't report PSTN <OK> TO EXIT READY 12:00PM
D-302887
Enter installer code (9999 by default)
Press Press Press Press Press Press 4 times once twice once once once once once once 8 times once
10. Press
Address twice once once
Example: S&W Primary IP Address (069. 074. 192. 027)
19. Press
8
twice 9 times once once 4 times once once once once
Example: S&W Backup IP Address (208. 017. 225. 027)
13. SETTING USER CODES
You can program a security code for yourself and additional 7 codes for other system users.
Action(s) 1. 9.
Press Press Enter master user code (1111 by default) Press Press Press (The user code is 1111 by default) Enter 4 digit code e. g. 6854 Press Press 4 times 2 times
Resultant Display USER SETTINGS ENTER CODE SET BYPASS SET USER CODES USER CODE 1 USER CODE 1 1 1 1 1 USER CODE 1 6 8 5 4 USER CODE 1 6 8 5 4 USER CODE 2 USER CODE 2 USER CODE 2 0 0 0 0 USER CODE 2 2 3 5 1 ACCESS TO PART U02: P1 U02: P1 P2 P2 P3 P3 Entering user settings menu
10. Press
select partition by push buttons 1, 2 and 3 (for partition 1&3 enter 13)
15. Press
twice
USER CODE 2
as required for the other user codes (3-8) and act as in steps 11-15
SET USER CODES
14. [. . . ] PSTN REPORTING TO CENTRAL STATION
Action(s) 1. 9.
Press Press 3 times once
Resultant Display INSTALLER MODE ENTER CODE 1. REPORTING REPORT EVENTS 1ST REPORT METHOD disable PSTN PSTN 1ST RPRT METHOD <OK> TO EXIT READY 12:00PM
Enter installer code (9999 by default)
Press Press Press Press Press Press 4 times once twice once once once twice once once once once
10. Press
For PSTN / phone line reporting, no other changes are necessary.
D-302887
11
VISONIC LTD. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VISONIC POWERMAXCOMPLETE PANEL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.