If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VISONIC POWERMAXCOMPLETE PANEL. We hope that this VISONIC POWERMAXCOMPLETE PANEL user guide will be useful to you.

Lastmanuals help download the user guide VISONIC POWERMAXCOMPLETE PANEL.


Mode d'emploi VISONIC POWERMAXCOMPLETE PANEL
Download
Manual abstract: user guide VISONIC POWERMAXCOMPLETE PANELQUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] 7 - MCT-320 INSTALLATION Magnet 2 Push catch and remove board 3 Insert battery Front Tamper switch Back Tamper switch (option) Remove spacer 1 3mm spacer A. Fasten the spacer to mounting surface with 2 screws. Locate the magnet on the spacer at the correct direction and push it upward. 2 1 Release screw and remove cover 4 Mounting Note It is highly recommended to attach the transmitter to the top of the door/window on the fixed frame and the magnet to the movable part (door or window). Make sure that the magnet is located not more than 6 mm (0. 25 in. ) from the transmitter's marked side. Fig. [. . . ] DEFINE PANEL 01: ENTRY DELAY 1 03: EXIT DELAY EXIT DELAY 60 S * 03: EXIT DELAY 10. 8) Press Press Press Select delay with and press 3 times Resultant Display 4. DEFINE PANEL 01: ENTRY DELAY 1 Entry dly1 30 s * 01: ENTRY DELAY 1 02: ENTRY DELAY 2 Entry dly2 60 s ** 6. 8. Press Press Select delay with and press 02: ENTRY DELAY 2 * The default ENTRY DELAY 1 time is 30 S. ** The default ENTRY DELAY 2 time is 60 S. 6 D-302887 11. SETUP FOR GPRS/BB ­ NO PHONE LINE (STEP 1) DO NOT make any program changes in "DEFINE COM" other than those shown on this instructions unless necessary. Before continuing, remove power (AC and battery) and install a SIM card provisioned for GPRS data service. Request a SIM card phone number from your SIM supplier if you wish to have the ability to ARM / DISARM via text messaging or program from the central station receiver. Action(s) 1. 9. Press Press 3 times once Resultant Display INSTALLER MODE ENTER CODE 1. 1:PSTN/GSM 2:GPRS/BB GPRS REPORT disable enable GPRS REPORT GPRS APN Enter installer code (9999 by default) Press Press Press Press Press Press 4 times once once once once once twice 3 times once 10. Enter Access Point Name airnet1 Example: Seaguard SIM = airnet1 (Key #8 = scroll symbols up, Key #2 = scroll symbols down) (Key #5 = Toggle Uppercase / Lowercase) 14. Press twice once once GPRS APN <OK> TO EXIT READY 12:00PM D-302887 7 12. REPORTING ­ NO PHONE LINE (STEP 2) Action(s) 1. 9. Press Press 3 times once Resultant Display INSTALLER MODE ENTER CODE 1. REPORTING REPORT EVENTS 1ST RPRT METHOD disable cellular cellular 1ST RPRT METHOD IP RCVR 1 000. 000. 000. 000 069. 074. 192. 027 IP RCVR 1 IP RCVR 2 000. 000. 000. 000 208. 017. 225. 027 IP RCVR 2 LINE FAIL REPORT PSTN 5 minutes don't report don't report PSTN <OK> TO EXIT READY 12:00PM D-302887 Enter installer code (9999 by default) Press Press Press Press Press Press 4 times once twice once once once once once once 8 times once 10. Press Address twice once once Example: S&W Primary IP Address (069. 074. 192. 027) 19. Press 8 twice 9 times once once 4 times once once once once Example: S&W Backup IP Address (208. 017. 225. 027) 13. SETTING USER CODES You can program a security code for yourself and additional 7 codes for other system users. Action(s) 1. 9. Press Press Enter master user code (1111 by default) Press Press Press (The user code is 1111 by default) Enter 4 digit code e. g. 6854 Press Press 4 times 2 times Resultant Display USER SETTINGS ENTER CODE SET BYPASS SET USER CODES USER CODE 1 USER CODE 1 1 1 1 1 USER CODE 1 6 8 5 4 USER CODE 1 6 8 5 4 USER CODE 2 USER CODE 2 USER CODE 2 0 0 0 0 USER CODE 2 2 3 5 1 ACCESS TO PART U02: P1 U02: P1 P2 P2 P3 P3 Entering user settings menu 10. Press select partition by push buttons 1, 2 and 3 (for partition 1&3 enter 13) 15. Press twice USER CODE 2 as required for the other user codes (3-8) and act as in steps 11-15 SET USER CODES 14. [. . . ] PSTN REPORTING TO CENTRAL STATION Action(s) 1. 9. Press Press 3 times once Resultant Display INSTALLER MODE ENTER CODE 1. REPORTING REPORT EVENTS 1ST REPORT METHOD disable PSTN PSTN 1ST RPRT METHOD <OK> TO EXIT READY 12:00PM Enter installer code (9999 by default) Press Press Press Press Press Press 4 times once twice once once once twice once once once once 10. Press For PSTN / phone line reporting, no other changes are necessary. D-302887 11 VISONIC LTD. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VISONIC POWERMAXCOMPLETE PANEL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VISONIC POWERMAXCOMPLETE PANEL will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag