User manual VISONIC TOWER 12 AM INSTALLATION MANUAL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual VISONIC TOWER 12 AM. We hope that this VISONIC TOWER 12 AM user guide will be useful to you.
Lastmanuals help download the user guide VISONIC TOWER 12 AM.
Manual abstract: user guide VISONIC TOWER 12 AMINSTALLATION MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] The TOWER 10 AM PIR and TOWER 12 AM Dual Technology are professional vandal resistance Anti-Masking detectors designed for large commercial and industrial applications providing wide coverage with superior resistance to harsh environment, employing several revolutionary patented technologies. Both detectors comply with EN 50131 Grade 3. features: · V-slot® recessed small window technology (patent pending) for extreme mechanical robustness and protection from false alarms (patent pending). [. . . ] Vertical adjustment: Angled base surface provides three tilt adjustments according to mounting height and coverage range. Low voltage detection: If input voltage is below 7. For pet immunity (up to 18Kg/40lb), a special "pet mask" model PET 10/12 should be mounted on the mirror (see figure 6, step 4a). The LEDs will flash alternately, indicating that the detector is adapting itself to its present surroundings. Stay at least 1m (3ft) away from the detector, until the 60 seconds startup period ends (until the LEDs stop flashing alternately). Enter the detector's field of view and perform walk test in the entire coverage area, while observing the red LED (see figure 2). for TOWER 12 , observe also the green LED for MW and PIR detections (see "LED indications" table in the specifications). The red LED will light for 2-3 seconds each time the alarm output is activated (see figure 2). Instruct the user to perform walk test at least once a week to verify proper operation of the detector. Tape a piece of cardboard to the detector's front to deliberately mask the optical window. After 30 seconds, the yellow LED should light (the TRB relay drops out). The yellow LED should extinguish (after a few seconds). Home and property owners or renters should be prudent enough to continue insuring their lives and property, even though they are protected by an alarm system. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. [. . . ] It is therefore recommended that the detector and the entire alarm system be checked weekly, to ensure proper performance. When TST input not in use, set polarity to 0V. "+TRB" - open upon alarm, masking event, self test failed or low voltage. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VISONIC TOWER 12 AM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VISONIC TOWER 12 AM will begin.