Manual abstract: user guide VISONIC TOWER 20 AMINSTALLATION
Detailed instructions for use are in the User's Guide.
[. . . ] Pet- immune: Up to 18Kg (40lb. ) ELECTRICAL Input Power: 8-16VDC Standby Current: 15mA@12VDC. (red and yellow LEDs light steadily) Low Voltage Detection: If input voltage is below 7. 5 VDC Outputs:
9m (30ft)
TOP VIEW
6m (20ft) 3m (10ft) 0 3m (10ft) 6m (20ft) 9m (30ft)
0
90°
3 10
6 20
9 30
12 m 40 ft
Alarm output: Solid State Relay. NC, 100 mA / 30 V, 35 ohm maximum internal resistance. (see Table 4).
2. 4 m (8 ft)
SIDE VIEW O F EACH DETECTOR
0
3 10
6 20
9 30
12 m 40 ft
Trouble output: Solid State Relay. [. . . ] The vertical angle indicator position for various installation height and coverage distance combinations is detailed in Table 2 (the information refers to a relatively flat surveyed area. however, in any case the vertical adjustment should be verified by walk-test).
Table 2 - Vertical Adjustment Reference Coverage Distance Mounting 2m / 6. 7ft 4m / 13ft 6m / 20ft 8m / 26ft 10m / 33 ft 12m / 39 ft Height 3. 0m / 9, 8 ft 1 2 2 3 3 2. 5m / 8, 2 ft 1 1 2 3 4 4 2. 0m / 6. 7 ft 1 2 3 4 5 5 1. 5m / 4. 9 ft 2 3 4 5 -
4
OFF
*
**
Switching from OFF to ON resets the detector for a stabilization period of 60 sec. and causes the detector to re-adapt to its current surroundings. Remain at a distance of at least 0. 5 m (1. 5 ft. ) from the detector to prevent disruption of this process. Use ON for EN approved control panels / installations. However, many installers prefer not to have the ALARM relay opened on a masking event.
3. 5 Test
A. Set the detector in Walk-Test mode, by setting DIP switch 1 (LEDs ON/OFF) to ON position (see Fig. 3, steps 10 and 11), or activate the remote TST input by connecting it to GND. Walk into the detector's field of view at the expected far edge of the coverage area. Verify that each time your motion is detected the red LED lights for 2 seconds and the control panel receives the alarm. If required, perform detector's horizontal / vertical readjustments.
D-301524
1
Important!Instruct the user to perform walk test at least once a week, to verify proper operation of the detector. Place a piece of cardboard on the detector's front side, to deliberately mask the optical window. After 2 minutes, the yellow LED should light (see Table 3) and the alarm control panel should receive the masking alarm. Remove the masking from the detector's front side. The LED should extinguish (after about 30 seconds).
Event / status Low voltage Warm-up (60sec. ) Self-test failure AM detection ALARM Table 3 LED Operation Indication Red flashing Yellow + Red flashing alternately Yellow + Red flashing simultaneously Yellow ON Red ON for 2 sec.
Table 4 Relay Outputs Relay Output Event / status Trouble Alarm Complete power failure Open Open Standby Closed Closed Low voltage Open Closed Self-test failure Open Closed AM detection DIP-SW4 = ON Open Open AM detection DIP-SW4 = OFF Open Closed Alarm Closed Open for 2 sec.
3. 6 Cover Closure
(see Fig. 4, steps 7 - 10)
Tamper switch
1
Mark
2
3
Drill
4
Press firmly to release the bracket
5
6
For wall Tamper switch
7
Bracket fastening (3 cable routing options)
Fasten
Note The 2 screw holes enable adjustment of the bracket on the wall, if needed as a result of the walk test.
(3 long screws)
Wiring
10
DIP switches
OFF 1 2 3 4
ON
SPARE
(2 short screws)
8
9
12 VDC
24-HOUR TAMPER ZONE
TEST SWITCH (OPTION)
BURGLAR 24 HOUR ZONE N. C. TROUBLE ZONE N. C.
ALARM CONTROL PANEL
Figure 3 - Installation
2
D-301524
Mounting on bracket
A
11
B
12
3 screws
Figure 3 Installation (Continued)
HORIZONTAL ADJUSTMENT (-45° to +45°)
Adjust
1
Release locking
2
3
Lock
VERTICAL ADJUSTMENT (0° to -10° in 2. 5° clicks / steps)
Adjust
4
Release locking
5
Vertical angle steps
5 3 1
6
4 2
Lock
Figure 4 Adjustment and Cover Closure
D-301524
3
COVER CLOSURE
8
7
Turn cover
9
Cover closure Push slider
10
Figure 4 - Adjustment and Cover Closure (Continued)
4. MISCELLANEOUS COMMENTS
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. [. . . ] The Manufacturer shall not be responsible for dismantling and/or reinstallation costs. To exercise this Warranty the Product must be returned to the Manufacturer freight pre-paid and insured. All freight and insurance costs are the responsibility of the Purchaser and are not included in this Warranty. This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on its behalf in the modification, variation or extension of this warranty. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VISONIC TOWER 20 AM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual VISONIC TOWER 20 AM will begin.