Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WAVECOM TNT+. We hope that this WAVECOM TNT+ user guide will be useful to you.
Lastmanuals help download the user guide WAVECOM TNT+.
Detailed instructions for use are in the User's Guide.
[. . . ] Australian made to comply with the requirements of the Standard AS/NZS 3760
REVISION 1. 11 February 2005
Ph: (07) 3274 2466 Int: (+61) 7 3274 2466 www. nesco. com. au
Email: admin@wavecom. com. au
Ph: (08) 8331 8892 Int: (+61) 8 8331 8892
Email: sales@nesco. com. au
www. wavecom. com. au
Accessories Supplied
(With the Range of TnT Portable Appliance Testers)
· · · · ·
Portable Appliance Tester Instruction Manual Manufacturers Calibration Certificate IEC Lead Earth Lead with Alligator Clip Soft Carry Case
Manufacturers Recommendations
(For the Range of TnT Portable Appliance Testers)
Calibration: The manufacturer recommends a routine calibration verification of readings for determining the accuracy of readings on a 12 Monthly basis.
Page 2
Index
Accessories Supplied Manufacturers Reccomendations Index 2 2 3 4 5 6 6 7 8 9-10 10 11 12 13 14 15 16 17
IMPORTANT INFORMATION:
Safety Warning The TnT Portable Appliance Tester (Diagram) Competent Person Disclaimer & Limited Warranty
TECHNICAL INFORMATION: Class 1 (Earthed Appliance) Construction Class 2 (D/Insulated) Construction Testing of Electrical Equipment To Change Test Voltage (250/500VDC Select) INTEGRATED TESTS: FIRST TEST: SUPPLY MAINS TEST NCNT TEST VISUAL INSPECTION TEST
CHAPTER 1 TnT Portable Appliance Tester Instructions: TnT Test Function Flow Chart EARTHED APPLIANCE TEST DOUBLE INSULATION TEST EXT LEAD TEST CHAPTER 2 - TnT-el Portable Appliance Tester Instructions: TnT-el Test Function Flow Chart TESTS Common to ALL MODELS LEAKAGE TEST CHAPTER 3 TnT+ Portable Appliance Tester Instructions: TnT+ Test Function Flow Chart TESTS Common to ALL MODELS POWER TEST RCD TEST Specifications for the TnT, Tnt-el & TnT+ Optional Accessories Other Relevant Authorities
18 19 20-21
22 23 24-25 26-30 31 32 33
[Please note: Specific PAT Tests are noted in blue text]
Page 3
Safety Warning
!
When using any electrical appliance SAFETY must always be observed. Testing appliances is no exception and in fact MORE care must be taken to ensure personal safety is met. Although the TnT range of products has been designed to meet stringent requirements, no person can be completely protected against the consequences of the incorrect use of an electrical device. We advise that appliance testing should be conducted by a competent and suitably trained person. [. . . ] [refer to page 13 for more details]
The Ext. Lead TEST completes the following sequence as part of its comprehensive testing procedure:
[see page 11 for details] 1. EARTH BOND TEST (@200ma) :200Ma Test Current. INSULATION TEST (@ 250v or 500v) Pass Level GREATER than 1M 4. CONTINUITY & POLARITY TEST 250VAC Checks continuity & polarity of leads
PROCEDURE: 1. Complete a VISUAL INSPECTION on the DUT (Device Under Test) [refer to page 13 for details `Visual Inspection']. IF THE DUT PASSED THE `VISUAL INSPECTION', CONTINUE WITH THE FOLLOWING INSTRUCTIONS [if not, refer to page 13 'IF RESULT IS A FAIL' ]: 2. Plug in IEC adaptor lead into IEC socket ( Remove Earth lead if inserted - Please read note below) 3. Plug Male end of Extension lead or Power board into TnT tester DUT socket 4. Plug IEC adaptor lead into Extension lead /Power board socket. Read the result and record appropriately. Press the Enter key to return to the Main Menu. IF THE RESULT OF THE TEST WAS A `PASS' - Tag the DUT with the appropriate tag, including `Next test Due' date and return to service. IF THE RESULT OF THE TEST WAS A `FAIL' - Tag the DUT with a DANGER TAG AND REMOVE THE DUT FROM SERVICE. Extension leads should always be uncoiled before using or testing. Please ensure that the IEC Adaptor & the IEC socket are inserted firmly or it may result in a continuity/polarity fail.
[Illustration above is for demonstration only]
Page 17
Chapter 2 - TnT-el Portable Appliance
Part No: WCM-TNT-EL
Test Instructions
TnT-el Test Function Flow Chart
Please note: Menu 1 is common to all models [TnT, TnT-el & TnT+]
Main Menu 1 F1 Earth Test F2 D/Ins Test F 3Ext Lead Test Menu 2 F1Earthed Leakage Test F2 D/Ins Leakage Test F3 RCD Appliance Leakage Test
F1 Earth Test Mains Supply Test NCNT Test Earth Bond Test Insulation Test Results Summary
F1 Earthed Leakage Test Mains Supply Test NCNT Test Earth Bond Test Earth Leakage (5mA) Results Summary
F2 D/Ins Test Mains Supply Test NCNT Test Double Ins Test Results Summary
D/Ins Leakage Test Mains Supply Test NCNT Test Earth Leakage (1mA) Results Summary
F3 Ext Lead Test Mains Supply Test Earth Bond Test Insulation Test Continuity & Polarity Test Results Summary
RCD Appliance Leakage Test Mains Supply Test NCNT Test Earth Bond Test Earth Leakage (2. 5mA) Results Summary
Page 18
Chapter 2 - TnT-el Portable Appliance Test Instructions
TESTS COMMON TO ALL MODELS Menu 1
EARTHED APPLIANCE TEST DOUBLE INSULATION TEST EXT LEAD TEST
[refer pg 15] [refer pg 16] [refer pg 17]
Please note: Menu 1 is common to all models [TnT, TnT-el & TnT+]
Page 19
Chapter 2 - TnT-el Portable Appliance Test Instructions
LEAKAGE TEST Menu 2
The Leakage Test is an alternate method to performing insulation resistance tests. Leakage testing is a major function of the TnT-el & Tnt+ models
PLEASE NOTE: A VISUAL INSPECTION MUST BE CARRIED OUT BEFORE ANY OTHER TESTS. [refer to page 13 for more details]
This test determines errors of leakage not otherwise detected in a normal insulation test. If there are any doubts with insulation testing of the equipment, the Standard (AS/NZS 3760 since 2001) allows for a leakage test to be carried out instead. The TnT-el & TnT+ appliance testers have been designed to perform these tests. The Leakage Test applies power to the Device Under Test (DUT) and measures any imbalance or leakage current. The leakage is tested to the limits of the class types specified in the Standard AS/NZS 3760 ie. [. . . ] I. E if set test current were 100mA then 100 X 5. 0 =500mA. If set test current = 200mA then maximum out put 5 x 200ma =1A is out of range. Unit will not deliver this output current and display on Screen "OUT of RANGE".
Page 29
Chapter 3 TnT+ Portable Appliance Test Instructions
RCD TEST [continued] Menu 2
Press F3 to START test. TnT+ display will display result for 20 seconds after mains supply is tripped.
!
CAUTION Pressing F3 at this point will cause tripping if RCD fitted to circuit.
TRIP CURRENT TEST. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WAVECOM TNT+
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WAVECOM TNT+ will begin.