Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL 6ADP2956 IXM. We hope that this WHIRLPOOL 6ADP2956 IXM user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL 6ADP2956 IXM.
Manual abstract: user guide WHIRLPOOL 6ADP2956 IXMSERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] This documentation is intended only for qualified technicians who possess the required qualifications and are aware of the regulatory requirements applicable to servicing electrical appliances.
Whirlpool (Australia) Pty Limited A. SM4017
WHIRLPOOL CONSUMER SERVICES
BLANK PAGE
Model 6ADP2956 IXM
Page 2 of 19
WHIRLPOOL CONSUMER SERVICES
Model 6ADP2956 IXM
Page 3 of 19
CONTENTS
Page TECHNICAL DATA EXPLODED VIEW - CABINET EXPLODED VIEW - DOOR AND CONTROL PANEL SPARE PARTS LIST PROGRAMME CHART CIRCUIT DIAGRAM TEST PROGRAMME PROCEDURE FOR DIAGNOSTIC SERVICE TEST PROGRAMME PASSIVE TEST PROGRAMME FAULT DIAGNOSIS ACTIVE TEST PROGRAMME CONTROL BOARD TEST POINTS 4-5 6 7 8 - 11 12 13 14 14 - 15 15 16 - 17 18 19
WHIRLPOOL CONSUMER SERVICES
TECHNICAL DATA Dimensions
Height Width Depth Mass 85. 0 60. 0 59. 2 59. 0 mm mm mm kg
Model 6ADP2956 IXM
Page 4 of 19
Electrical Data
Base Data Voltage Frequency Total power Fuse 230 - 240 50 2. 4 10 V Hz kW A
Decor Plate
Thickness (Max) Width Height Mass (Max) 4 583 595 1. 8 mm mm mm kg
Motors
Spray Pump Motor Voltage Power consumption. HI (in series with cap) HA Capacitor Drain Pump Motor Voltage Input Resistance Drying Fan Motor Voltage Resistance Total Air Volume 230 - 240 ~160 81 44 4 230 - 240 30 146 230-240 141 900 V W · · µF V W ·
Electronic Circuit Boards
Service Boards See Spare Parts
Serial Boards DUB 4619 724 06821 CB 417071 Dataset 417061 Basic control board not programmed, see on the board laminate 4619 724 04871
Programmes
Programmes Succession See Programme Chart 1a-2a-3b-6d-8-9
V · l/min
Water Pressure/Temperature
Inlet pressure, min. [. . . ] Do not attempt to measure open circuit voltage output from the control board.
PASSIVE TEST PROGRAMME
Start Passive test programme will indicate the mode of failure. If there is no failure, the test programme will result in the four programme progress lights in the display panel flashing sequentially. Turn the programme selector to the off ("O") position 2. Chosen programme LED lights Push and hold the start button while turning the programme selector to the first cycle (40°C-55°C Normal) until the start button light begins to flash. The start button light will flash in a sequence to indicate the mode of failure. Reset programme by pressing the start button for more than 3 seconds. Start passive test again and progress to active test by pressing the start button for less than 3 seconds
Four programme progress lights flash sequentially
3. 4.
Finish passive test programme by starting active test programme
5. 7.
WHIRLPOOL CONSUMER SERVICES
FAULT DIAGNOSIS
F0
Model 6ADP2956 IXM
Page 16 of 19
Sensor Failure There is no indication to the user for this fault. If the sensor fails, the machine will automatically default to the programme with the highest washability. The fault will be indicated after 10 s to 30 s of the active test programme. The test programme will terminate and the F0 fault code will be displayed. The defects that result in the faults are : No output or incorrect output from the sensor Readings outside preset limits which could be caused by : Defective electronic component in sensor Opto-electronic component failure in sensor Sensor cover is very discoloured from deposited soil Connections between sensor and control board are broken.
F1
NTC (Negative Temperature Co-efficient of Resistance) Device - Temperature is outside normal range -3°C to +85°C - Temperature inside the wash chamber is over +85°C - The device is either open circuit or short circuit.
F2
Water Leakage Water is in drip tray - Float switch (LS6) operates, closes the water inlet valve and turns on the drain pump until the water Indicator (WI) reports empty.
F3
Heating System Defective Indicated after approximately 25 minutes of heating operation. - Element (HEW) defective - Relay (RE2) on control board is defective - NTC resistance fluctuation - Water indicator (WI) defective (open-circuit) - Spray pump is not working
F4
Draining Failure Drain pump energised and after four minutes Water Indicator (WI) still detects water. [. . . ] Before attaching test probes to the control board test points which are accessed via the control board service window, disconnect the dishwasher from the supply. Short circuiting of any of the electronic components will cause the control board to fail. Test Points : T0 = Common T1 = Analogue voltage Service Window T0 T3 T2 T1 T2 = Analogue voltage T3 = Digital signal
Control Board A voltmeter with a high input impedance is required to measure the control board voltages. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL 6ADP2956 IXM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.