If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL 8572777-D-WH. We hope that this WHIRLPOOL 8572777-D-WH user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL 8572777-D-WH.
Manual abstract: user guide WHIRLPOOL 8572777-D-WH
Detailed instructions for use are in the User's Guide.
[. . . ] ®
Gas Washer/Dryer
OVERALL DIMENSIONS
PRODUCT MODEL NUMBER LTG6234D
Gas supply: Dryer is equipped for use with
NATURAL gas. When rigid pipe is used it should be 1/2 inch IPS. [. . . ] Rigid or flexible metal exhaust vent must be used. Exhaust outlet hood must be at least 12 inches from the ground or any object that may be in the path of the exhaust. The dryer can be converted to exhaust out right or left side.
71/" (181. 9 cm)
23³/" (60. 3 cm)
* Most installations require a minimum 5¹/" (14 cm) clearance behind the dryer for the exhaust vent with elbow.
*32" (81. 3 cm) 27" (68. 6 cm)
32¹/" (81. 9 cm)
RECESSED AREA AND CLOSET INSTALLATION
Additional clearances might be required for wall, door and floor moldings. Rear clearance may be 0" when house exhaust system is lined up directly with dryer exhaust.
A
B
6" (15. 2 cm) 48 in. 2 (310 cm2)
C
3" (7. 6 cm)
EXHAUST VENTING Plan installation to use the fewest number of elbows and turns. Maximum length of the exhaust system depends upon the type of vent used, number of elbows and the type of exhaust hood. The maximum length for both rigid and flexible vent is shown in the chart.
B 2
4" (10. 2 cm)
24 in. 2 (155 cm2) 1" 32" 27" 1" 1" (2. 5 cm) (68. 6cm) (2. 5cm) (2. 5 cm) (81. 3 cm) 5¹/" (14 cm)
3" (7. 6 cm)
A 1
4" (10. 2 cm) 4" (10. 2 cm)
A. Closet door with vents
(6. 4 cm)
Angled hood style
DRAIN SYSTEM
Standpipe drain system - wall or floor The standpipe drain requires a minimum diameter standpipe of 2" (5 cm). The minimum carry-away capacity can be no less than 17 gal. A 2" (5 cm) diameter to 1" (2. 5 cm) diameter standpipe adapter kit is available. The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (2. 4 m) from the bottom of the washer. Laundry tub drain system The laundry tub needs a minimum 20 gal. The top of the laundry tub must be at least 34" (86. 4 cm) above the floor and no higher than 96" (2. 4 m) from the bottom of the washer. [. . . ] For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL 8572777-D-WH
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.