If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL ADG 8242 IX. We hope that this WHIRLPOOL ADG 8242 IX user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL ADG 8242 IX.
You may also download the following manuals related to this product:
WHIRLPOOL ADG 8242 IX PROGRAM CHART (3473 ko)
Manual abstract: user guide WHIRLPOOL ADG 8242 IXPRODUCT FICHE
Detailed instructions for use are in the User's Guide.
[. . . ] B) If the power supply cord is damaged, it must be replaced by the Manufacturer, Service Agent or a similarly qualified person, in order to avoid a hazard. EARTHING INSTRUCTIONS A) This appliance must be earthed. In the event of malfunction or breakdown, earthing will reduce the risk of electric shock by providing a path of least resistance for electric current.
PLUMBING & DRAINAGE PREPARATION A) A readily accessible valve must be installed in the water supply pipe. B) If the supply pressure exceeds 1000kPa, then a pressure limiting valve must be used. [. . . ] Standpipe Ø38mm with Air Gap.
e y
+
R
+
97mm 580mm throughout cavity
User Guide on how to set up your water
600mm
+ These marks indicate mounting tab crew locations (refer to step 1 page 5)
Drain Connection Drain Hose Joiner to suit Ø19mm ± 2mm waste tee. Electrical Connection 230-240 VAC power outlet 9Amps Minimum. Toe Kick Depth Prefinished 50-65mm; Integrated 67mm less the Toe Kick Panel thickness (Minimum Panel thickness using the supplied screws is 9mm). # Door Front Height Prefinished 717. 5mm; Integrated 717. 5mm minimum. Length of Services Drain hose - 2250mm Inlet hose - 1750mm Power supply cord - 1965mm NOTE: Services approximately exit product 189mm from left; 550mm from front; 793mm from top.
PLEASE NOTE: It is NOT recommended to connect the to any part of the Waste Disposal System. Option 3
R
R
using Sink Trap with Drain Hose Joiner.
NOTE: All depth measurements are taken from the front face of the adjacent cabinetry.
Ensure the edges of the services hole are smooth or covered.
NOTE: Prefinished Model is shown. There is no variation in plumbing between Prefinished products and Integrated products. Option 1 and 2 are the preferred options. Options 1 & 2 or use of a Dual Inlet Airgap satisfy Kosher requirements.
SINGLE MODEL
SERVICE'S SPECIFICATION THE CAVITY
Ø50mm services hole can be either side, immediately adjacent to corner
(page 4 of 8)
PLUMBING OPTIONS
Option 1 and Standpipe Ø38mm with Air Gap.
*
90°
410mm
505
mm
+ + +
Min thickness of cavity sides is 16mm
97mm + 67mm 580mm throughout cavity 600mm
*For an Integrated the product depth is specified with an 18mm Integrated Door Panel thickness. Water Connection Recommended COLD (Maximum 60°C). 3/4 " BSP (GB20) to suit flat washer. Open the drawer (Bottom drawer in DOUBLE MODELS). Release the tub by depressing the right hand tub clip and pushing it back 30mm. Slide both runners back into the product. For SINGLE MODELS, depending on the height of the cavity, the tub will need to be supported, eg. on a chair.
1
DOUBLE MODELS ONLY C Mounting Tab Option If the top installation tabs C are to be used, fit to the chassis by inserting into the top slots as shown. Ensure the tabs are fully locked in place. Check cavity for any obstructions that may interfere with sliding the product back. Push product into cavity to suit adjacent cabinetry. Ensure inlet, drain hose(s) and power supply cord are not restricted or damaged by carefully pulling them through the services hole, while the product is being pushed back into the cavity.
2 3
The product must be levelled to within 2. 5mm from front to back, and side to side. TIP - Place a spirit level on the drawer runners to level the product.
4
SECURING THE PRODUCT
5
REFITTING THE TUB
6
CONNECTING THE DRAIN HOSE(S)
R
(page 6 of 8)
with Hose Joiner (see Plumbing Options).
10
Before refitting the tub, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward.
Remember to slip the wire clip(s) on the drain hose(s) first.
The Drain Hose support must be used.
15a
Ensure the Drain Hose(s) are fully extended.
11 12
NOTE - SINGLE MODELS do not have top tabs.
13
14
Drain Hose joiner MUST NOT support weight of hoses. Keep excess length of Drain Hose on the side of the Drain Hose support.
R
16 15b
10
SINGLE MODELS ONLY Check the position of the chassis is still where marked on the cavity, before securing the product. [. . . ] The should beep and light up.
R
23
Open the drawer(s) and check operation of Wash Programme Control Panel and check the sprayarm(s) are in place and free to rotate. On the Wash Programme Control Panel select Rinse and close the drawer(s). Start the programme by pressing the Start/Pause button. After the Rinse programme has finished, ensure machine has run and drained correctly. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL ADG 8242 IX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.