If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AGB 448/WP. We hope that this WHIRLPOOL AGB 448/WP user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL AGB 448/WP.
Manual abstract: user guide WHIRLPOOL AGB 448/WPINSTRUCTION FOR USE
Detailed instructions for use are in the User's Guide.
[. . . ] The combustion chamber and flues are made of electro-galvanised steel sheeting. The temperature is set using the safety taps provided. It goes from low (minimum) to high (maximum) through a range of easily selectable intermediate levels. connecting the gas supply, checking power rating, transforming or adapting the appliance to run on other types of gas, and commissioning, must all be done by contractors authorised by the local Gas Board in accordance with local and national legislation. [. . . ] The following are the operating pressure tolerances to obtain the nominal power according to the agreed nozzles: - from 15 to 22. 5 mbar for gases of the second family - from 25 to 45 mbar for gases of the third family (propane).
Capacity should only be measured when the appliance is at a standstill. The heat value can be obtained from your local Gas Board. To obtain the nominal and minimum capacities in relation to the nominal pressure, consult table (1- Gas Flow Setting).
3
5
3
6 1 2 4 22
The appliance will not work outside the above pressure threshholds. To adjust the capacity to its minimum value, use the data in tables 1 (Gas Flow Regulation table). If you wish to check the nominal capacity further, you may do so using a gas meter according to the so-called WARNING ”volumetric method”. It is not possible to adjust nominal capacity in adIt is normally enough, however, simply to check that the vance. nozzles are functioning correctly.
Checking input pressure (Fig. 3)
Input pressure should be measured using a gauge (e. g. Remove screw (22) from the pressure socket and connect it to the tube on the gauge; after measuring, the screw should be retightened absolutely airtight (22).
Checking power rating when using LP gas
Check that the type of nozzles used match table 1 specifications. Check that the output pressure regulator installed collaterally to the plant conforms to the specifications laid down in paragraph "Testing the power rating" (see data plate and measure the pressure).
013- 03 - Gas pasta cooker
10
Checking the pilot light
When correctly adjusted, the pilot light flame will completely surround the thermocouple and will not flicker; ; if it does, adjust the pilot flame as described in paragraph “Pilot burner adjustment”.
Replacing the main burner nozzle
To change nozzle (30), open the doors. Unscrew the nozzle from the nozzle holder using a 12 spanner; replace with a new nozzle (see “TECHNICAL DATA” table). If necessary, to make changing the nozzle easier, loosen screws (39) to remove the air adjustment sleeve.
Checking the primary air
The appliance can be adjusted. Air volume flow is correct when there is sufficient protection against the flame rising when the burner is cold or light-back when it is hot. Position the ring at measurement “A” (Fig. 1) indicated in table 1 for type of gas.
Pilot burner adjustment (Fig. 2)
The pilot burner is easily accessible once the doors have been opened. Remove screw (35) and adjust the flame with a screwdriver. Once adjusted, replace and tighten screw (35) inserting the relative gasket. 3)
Loosen the gas piping and thermocouple hoses, then All parts must be replaced by authorised techni- loosen the screws fixing the gas supply to the gas ramp and insert a new tap. To replace the following parts, first remove the control knobs, slide out the fat tray and remove the control pa- Thermocouple (Figs. 2 & 3) nel (after unscrewing its fixing screws). Loosen the screws fixing the thermocouple (38) to the gas (6) tap and the pilot burner (34); insert the new part. [. . . ] Protection of stainless steel Never use running water, as this could infiltrate into the in- Should the equipment not be used for a certain period of ner parts. time, clean the external stainless steel surfaces and when Food stains and encrusted food particles: they are completely dry, protect by spreading over them a wash with hot water before they harden. Should food par- thin film of vaseline oil, or better still specific products to ticles have already become hard, use water and soap or be found on the market. chlorine-free detergents, if necessary using a wooden Apart from giving the steel a uniform, polished appearanspatula or fine stainless steel wool: rinse and dry thorou- ce, these products prevent penetration of humidity and ghly. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AGB 448/WP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.