User manual WHIRLPOOL AGB 511/WP INSTRUCTION FOR USE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AGB 511/WP. We hope that this WHIRLPOOL AGB 511/WP user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL AGB 511/WP.


Mode d'emploi WHIRLPOOL AGB 511/WP
Download
Manual abstract: user guide WHIRLPOOL AGB 511/WPINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] Warning!: Follow the fire prevention regulations very carefully. 2 - CHARACTERISTICS OF THE APPLIANCES The data plate is located on the rigth hand side of the control panel and contains all the data needed for connecting it up to the mains electricity supply. TIPO/TYPE MOD. m3/h CAT/KAT II2H3B/P II2H3+ II2H3+ II2L3B/P II2ELL3B/P II2E+3+ II2H3B/P I2E II2H3B/P II2H3+ I3B/P I3+ GAS/GAZ P mbar P mbar P mbar P mbar P mbar P mbar P mbar P mbar P mbar P mbar P mbar P mbar G30 30 30 28 30 50 28 50 30 28 30 28 G31 30 37 37 30 50 37 50 30 37 30 37 G20 20 20 20 20 20 20 20 20 G25 25 20 25 SE IT ES NL DE FR AT LU EE EE NO CY LV LV MT LT LT CY IS HU BE CH FI CH IE DK PT GB GR CZ SK SI Predisposto a gas: - Gas preset: - Prevu pour gaz: Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: V AC kW Hz MADE IN ITALY THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS BEFORE INSTALLING AND USING THE APPLIANCE. THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL. 3 - TECHNICAL DATA Model AGB 511/WP Width (A) Depth (B) Height (C) Vat diameter Vat height Total volume Usable volume Voltage/Input Power Power cable Hot water connection Cold water connection Water pressure Pressure mm mm mm mm mm lt lt 800 700 900 400 450 58 50 400 V 3N / 230 V 3 kW 9 5 x 1. 5 mm2 / 4 x 2. 5 mm2 mm mm kPa bar 10 10 50 - 300 0. 5 037- 03 - Electric kettles 50 lt 5 Construction Main structure in AISI 430 with 4 adjustable height feet. [. . . ] : Only qualified technicians must perform the installation, maintenance and test of the appliance. : Before connecting any parts of the appliance to supplies, make sure that the latter is equivalent the requirements stated in the technical data plate, if the appliance has been designed for these supplies. 037- 03 - Electric kettles 50 lt 6 Connect the terminal on the lower right-hand side marked with the international symbol a connector with a nominal cross section <10 mm2. All the appliances installed and the earth system of the building shall be connected like this. Connection to waterworks Water inlet pressure must be between 50 and 300 kPa, otherwise install a pressure regulator on the line before the appliance. Install a cut-off valve for each supply on the line before the appliance. Water connections to 10 mm are fitted in the lower part on the right-hand side of the appliance. Make connections according to regulations currently in force. cording to standards. In addition, check that once the appliance has been installed, the power cord is neither subject to stretch nor in contact with nor surfaces. Now proceed to light the appliance as directed in the instructions for use. While the appliance is in use, voltage should not differ from the nominal voltage more than +/- 10%. The test report must be completed in full and submitted to the customer who should then sign in acceptance. With effect from this moment, the appliance is covered by the manufacturer’s warranty. Maintenance of the appliance Warning!: All maintenance operations shall only be performed by a technically qualified service centre!To ensure correct and safe operation, the appliance must be inspected and serviced at least once a year only. Maintenance includes also controlling the components and tear of pipes, feeding pipes, electrical components etc. It is advisable to replace worn components during maintenance operations to avoid the need for other maintenance calls and unexpected failures. It is also advisable to apply for a maintenance contract with the customer. Commissioning and testing Once all the connections have been made, the appliance and the overall installation must be checked following the directions given in this manual. Check in particular: - that the protective film has been removed from the external surfaces; - that the lower front panel removed for the electrical connection of the appliance has been fitted back into position; - that connections have been made in accordance with the requirements and directions indicated in this manual; - that all safety requirements in current standards, statutory regulations and directives have been met; - that the water connections are leak-free; - that the electrical connection has been performed ac- Possible failures and their elimination Warning!: Only technically qualified service centres can perform the operations described below!: Before resetting the safety thermostat, it is always necessary to eliminate the problem causing its activation! 037- 03 - Electric kettles 50 lt 7 USE AND CLEANING Warnings and hints for user This manual contains all the instructions required for a proper and safe use of our appliances. Keep the manual in a safe place for future consultation!This appliance is for catering use, hence they must be used only by trained kitchen staff. The appliance must always be kept under control during use. [. . . ] : Problems and failures may occur even when the appliance is used properly. Here is a list of the mist probably situations and controls that the operator should perform to avoid applying to a service centre unnecessarily. If the problem is not solved after the necessary controls, turn off the appliance immediately, unplug it, cut off any supplies and apply to a service centre. … the vat contents do not heat up: - check that the power ON/OFF switch installed before the appliance is on; - otherwise turn off the appliance and apply to a service centre, as the safety thermostat may have been activated due to an excess of temperature in the cooking vat. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AGB 511/WP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AGB 511/WP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag