User manual WHIRLPOOL AGB 552/WP INSTRUCTION FOR USE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AGB 552/WP. We hope that this WHIRLPOOL AGB 552/WP user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL AGB 552/WP.


Mode d'emploi WHIRLPOOL AGB 552/WP
Download
Manual abstract: user guide WHIRLPOOL AGB 552/WPINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] 70 kg C D A B C D A A C D C B D A AGB 610/WP 600 x 650 x 300 (440) Weight approx. 48 kg 800 x 650 x 300 (440) Weight approx. 70 kg A B C D Main switch Fat tray Pilot lamp (voltage) Pilot lamp (resistances) 004- 03 - Electric fry-top 5 Dimensions A A A 600 x 700 x 870 (1080) Weight approx. 82 kg 800 x 700 x 870 (1080) Weight approx. [. . . ] THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL. FRY-TOP Model Dim. : LxWxH (total h) of work surface 400 x 650 x 300 (440) 400 x 700 x 300 (510) 400 x 700 x 870 (1080) AGB 604-605-606/WP AGB 536-537-538/WP AGB 551-552-553/WP 400 x 650 x 300 (440) 400 x 700 x 300 (510) 400 x 700 x 870 (1080) 600 x 650 x 300 (440) 600 x 700 x 300 (510) 600 x 700 x 870 (1080) AGB 609/WP 600 x 650 x 300 (440) 600 x 700 x 300 (510) 600 x 700 x 870 (1080) 600 x 650 x 300 (440) 600 x 700 x 300 (510) 600 x 700 x 870 (1080) AGB 610/WP 600 x 650 x 300 (440) 600 x 700 x 300 (510) 600 x 700 x 870 (1080) 800 x 650 x 300 (440) 800 x 700 x 300 (510) 800 x 700 x 870 (1080) 800 x 650 x 300 (440) AGB 543-544-545/WP AGB 558-559-560/WP 800 x 700 x 300 (510) 800 x 700 x 870 (1080) 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 230 V 3 or 400 V 3N 5. 0 kW 5. 0 kW 5. 0 kW 5. 0 kW 5. 0 kW 5. 0 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 6. 75 kW 10 kW 10 kW 10 kW 10 kW 10 kW 10 kW 4 x 1. 5 mm2 or 5 x 1. 5 mm2 4 x 1. 5 mm2 or 5 x 1. 5 mm2 4 x 1. 5 mm2 or 5 x 1. 5 mm2 4 x 1. 5 mm2 or 5 x 1. 5 mm2 4 x 1. 5 mm2 or 5 x 1. 5 mm2 4 x 1. 5 mm2 or 5 x 1. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 4 x 2. 5 mm2 or 5 x 2. 5 mm2 Voltage rating Power Lead wire / Section 004- 03 - Electric fry-top 9 INSTALLATION INSTRUCTIONS Before beginning installation, remove all packaging from the appliance. Some parts are protected with an adhesive film which should be carefully removed. Any remnants of glue should be thoroughly cleaned using suitable substances such as benzine. Under no circumstances should abrasive substances be used. Fit the legs to the appliance; the appliance must be levelled using a spirit level. Slight irregularities can be levelled by adjusting the feet themselves. With table models, make sure that the base chosen is capable of supporting the weight of the appliance. The main switch or plug should be located in the vicinity of the appliance and easy of access. We recommend installing the machine under a range hood so that all the fumes are removed as quickly as possible. If the appliance is to be installed near walls, dividing walls, kitchen equipment or decorative pannelling, these should be in non-inflammable material or covered with non-inflammable material. Make sure that all fire prevention standards and safety precautions are strictly adhered to. Installation Installation, start-up and maintenance should only be carried out by expert personnel. All work required to install the appliance should be carried out in compliance with all local standards and regulations. The manufacturers decline all responsibility where poor performance is due to incorrect installation in disregard of the above conditions. Warning! In compliance with international regulations, when connecting the appliance to the mains power supply, a device with a minimum aperture of 3 mm between contacts must be fitted upstream of the appliance, allowing omnipolar disconnection of the appliance from the mains. Wiring When choosing the lead wire, make sure it has the following characteristics: it should be at least of the H07 RNF type and its section should be large enough for the appliance (see "Technical specifications and dimensions", Warning!MODEL AGB 551-552-553/WP Wire entry on top models is on the back wall, and underif this model is going to be mounted on its own, it must neath all other models. In both cases the terminal board is be fixed to the floor. The appliance should be fitted following the indica- Pass the wire through the core hitch and wire clamp, plug tions given in the drawing below. the leads into their terminals on the board and secure them. The earth lead must be a little longerthan the others so 1 RETRO that it is the last lead to disconnect if the wire clamp BACK ARRIERE breaks. RÜCKSEITE Unipotential The appliance must be connected up to a unipotential system. The connection screw is located on all top models at the back on the right hand side, while in other models it is located underneath the appliance on the right hand side. It is labelled. Warning! The manufacturers cannot be held responsible for any damage due to inadequate or incorrect installation. [. . . ] Never clean the appliance before it has cooled down. The user is responsible for delivering the unit at the end of Before starting to clean the appliance, disconnect from its life to the appropriate collection facilities. Failure to do so shall result in the user being subject to the penalties the mains. prescribed by the legislation in force on waste. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AGB 552/WP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AGB 552/WP will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag