If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AKF 112/IX. We hope that this WHIRLPOOL AKF 112/IX user guide will be useful to you.
Lastmanuals help download the user guide WHIRLPOOL AKF 112/IX.
Manual abstract: user guide WHIRLPOOL AKF 112/IXINSTRUCTION FOR USE
Detailed instructions for use are in the User's Guide.
[. . . ] GB
AKF 112 / 113
BUILT-IN GAS HOB
The use of a gas appliance produces heat and humidity in the room. Make sure the room is well-ventilated, or install an extractor hood with exhaust duct. In case of prolonged use, additional ventilation may be necessary (by opening a window or increasing the hood extraction speed). After use, make sure the knobs are in off position and close the main gas supply cock or the gas cylinder valve. [. . . ] • • • The electrical connections must comply with local regulations. The earthing of this appliance is compulsory by law. L Earth (yellow/green) N
REPLACING THE INJECTORS (see the injector table in the Instruction)
1. Using a suitable socket spanner, unscrew the injector to be replaced C. Replace it with the injector required for the new type of gas. For models with the triple-crown burner, proceed as shown in the figure: After undoing the two screws F and removing the cover G, replace both injectors H as previously described. Refit the cover G, ensuring perfect tightness of the seal before turning the hob on. Before installing the hob, remember to apply the gas setting label (included with the injectors) over the previous setting data.
IMPORTANT: the data relevant to the voltage and power absorption are indicated on the rating plate.
ASSEMBLY
After having cleaned the perimeter surface, apply the supplied gasket to the hob as shown in the figure.
Position the hob in the opening made according to the measurements given in the section DIMENSIONS AND DISTANCES TO BE RESPECTED (mm). NOTE: The power cable must be long enough to allow its removal from above. Use the brackets provided to secure the hob. Position the brackets at the holes on the bottom of the hob and fix them with the appropriate screws in order to adapt them to the thickness of the top.
ADJUSTING MINIMUM GAS SETTING OF TAPS WARNING
This operation must be performed by a qualified technician. To ensure that the minimum setting is correctly adjusted, remove the knob E and proceed as follows: • tighten screw to reduce the flame height (-); • loosen screw to increase the flame height (+). The adjustment must be performed with the tap in minimum gas setting position (small flame) . • The primary air of the burners does not need to be adjusted. • At this stage, light up the burners and turn the knobs from max position to minimum position to check flame stability.
MIN. 15 mm
REFERENCE TO LOCAL REGULATIONS
Regulation for room ventilation NOTE: if the appliance is not equipped with safety devices on the burners (thermocouples), the air vents must be increased by 100%, and must be at least 200 cm2), in compliance with M. D. Connection to gas supply Before connecting the appliance, make sure that the gas supply system complies with standards UNI-CIG 7129 and UNI-CIG 7131. Gas connection The connection to the mains gas network or gas cylinder must be made using a rigid copper or steel pipe with fittings complying with standards UNI-CIG 7129, or using a continuous-surface stainless steel hose complying with standards UNI-CIG 9891. The pressure control valves to be used must comply with the UNI EN 12864 standard for gas cylinders and the UNI EN 88 standard for piped methane gas.
MIN. 15 mm Fit a wooden shelf at least 20 mm thick under the hob, at a distance of at least 15 mm from the bottom of the hob.
MIN. 15 mm
ADJUSTMENT TO DIFFERENT TYPES OF GAS WARNING
This operation must be performed by a qualified technician.
IE
REFERENCE TO LOCAL REGULATIONS
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the injectors. Remove the information label and keep it with the instructions booklet. [. . . ] Any baked-on food should be removed with a toothpick or needle. NOTE: to avoid damaging the electric ignition device, do not use it when the burners are not in their housing. NOTE: Continuous use of the hob could cause the original colour to change at the burners, due to the high temperature of the flame.
ቨ ቩ
Symbols
Tap closed Maximum flame Minimum flame
CLEANING THE HOB PARTS
PRATICAL ADVICE FOR USING THE BURNERS
This hob has burners of different diameters. For better burner performance, please stick to the following rules: - Use pots and pans with bottoms the same width as that of the burners or slightly larger (see table on the right). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AKF 112/IX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.