User manual WHIRLPOOL AKM 293/IX INSTRUCTION FOR USE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AKM 293/IX. We hope that this WHIRLPOOL AKM 293/IX user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL AKM 293/IX.


Mode d'emploi WHIRLPOOL AKM 293/IX
Download
Manual abstract: user guide WHIRLPOOL AKM 293/IXINSTRUCTION FOR USE

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTIONS FOR USE DESCRIPTION OF PRODUCT AND SYMBOLS BURNER OPERATION PRACTICAL ADVICE FOR USING THE BURNERS GRID POSITIONING DIMENSIONS AND DISTANCES TO BE RESPECTED (mm) INJECTOR TABLE PRECAUTIONS AND GENERAL RECOMMENDATIONS PROTECTING THE ENVIRONMENT INSTALLATION (FLUSH OR SEMI-FLUSH) GAS CONNECTION ELECTRICAL CONNECTION FIXING TO THE SUPPORT STRUCTURE CONVENTIONAL FITTED MODEL (SEMI-FLUSH) FIXING TO THE SUPPORT STRUCTURE FLUSH-MOUNTING MODEL CONVERSION TO DIFFERENT TYPES OF GAS REPLACING INJECTORS COCK MINIMUM SETTING ADJUSTMENT CLEANING AND MAINTENANCE CARE AND CLEANING OF HOB COMPONENTS TROUBLESHOOTING GUIDE AFTER-SALES SERVICE 17 DESCRIPTION OF PRODUCT AND SYMBOLS 1. Removable grids 4-crown burner Semi-rapid burner Auxiliary burner 4-crown burner control knob Semi-rapid burner control knob Auxiliary burner control knob 5 2 3 4 6 Symbols Cock closed Max. Turn the corresponding knob anticlockwise to the max. Press the knob against the control panel to light the burner. [. . . ] • Natural air circulation is ensured through an adequate opening in the wall of at least 100 cm2 useful section, which must be: - Permanent and in walls to the outside of the room; - Made in such a way that it cannot be obstructed from the inside or outside (even accidentally); - Protected by plastic grilles, metal mesh, etc. , which do not reduce the above-mentioned useful area; - Located near the floor and positioned so as not to interfere with the operation of the fume exhaust devices. 23 GAS CONNECTION The gas supply system must comply with the local regulations. • The section “national regulations” gives the specific local regulations for the country of use. • If no information concerning your country is given, please ask your installer for more details. • The hob must be connected to the gas supply or gas cylinder by means of a rigid copper or steel pipe with fittings complying with the local regulations, or by means of a continuous-surface flexible stainless steel tube complying with the local regulations. The maximum permissible length of the flexible metal tube is 2 metres. • Before connecting the tube to the elbow (A), fit the gasket (B) supplied, in compliance with EN 549. Important: If a flexible stainless steel tube is used, it must be installed in such a way that it cannot come into contact with any movable parts such as kitchen unit drawers or doors, passes through in a place free of hindrances, and its entire length can be inspected. • After connection to the gas supply, check for leaks with soapy water. ELECTRICAL CONNECTION The electrical connections must comply with the local regulations. • The data relevant to voltage and absorbed power is given on the dataplate. • Earthing of the appliance is compulsory by law. • When installing, provide for an omnipolar cutout switch with contact opening distance of at least 3 mm. • If the power cable needs replacing, use one having the same characteristics as the original supplied standard (type H05V2V2-F T90°C or H05RRF). This operation must be performed by the After-Sales Service. • The manufacturer declines any liability for possible damage or injury due to non-compliance with the above-mentioned rules. L Earth (Yellow/Green) N 24 FIXING TO THE SUPPORT STRUCTURE CONVENTIONAL FITTED MODEL (SEMI-FLUSH) 320 80 Important: The following operation must be carried out by a competent technician. Installation can be carried out on different materials: such as masonry, metal, solid wood and plastic laminated wood provided it is heat resistant (T 90°C). Make an opening in the top, of the dimensions shown in fig. Carefully apply the insulating sealing strip (supplied) around the outside edge of the hob as shown in the figure below, pressing lightly to make it adhere (Fig. 2 Fix the hob with the special brackets supplied. The supply includes 2 types of brackets: - 8 of standard length (Service Code 4812 404 49874) for installation on kitchen tops thicker than 4 cm - 8 longer than standard (Service Code 4812 404 49875) for installation on kitchen tops less than 4 cm thick The brackets must be fixed with the special screws to the front (4) and the back (4) using the seats on the bottom of the hob (Fig. Important: The power cable must be long enough to allow the hob to be removed upwards. Fig. 3 27 8 -+1 0 25 FIXING TO THE SUPPORT STRUCTURE FLUSH-MOUNTING MODEL Important: The following operation must be carried out by a competent technician. Installation can be carried out on different materials such as masonry, metal, solid wood and plastic laminated wood provided it is heat resistant (T 90°C). [. . . ] Correctly refit burners and burner caps. When refitting the grids, make sure the potstand zone is aligned with the burner. Note: For models equipped with electric igniters and safety thermocouples, the end part requires thorough cleaning in order to ensure correct operation. Check frequently and, if necessary, clean them with a damp cloth. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AKM 293/IX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AKM 293/IX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag