User manual WHIRLPOOL AKR 948 IX PROGRAM CHART

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual WHIRLPOOL AKR 948 IX. We hope that this WHIRLPOOL AKR 948 IX user guide will be useful to you.

Lastmanuals help download the user guide WHIRLPOOL AKR 948 IX.


Mode d'emploi WHIRLPOOL AKR 948 IX
Download

You may also download the following manuals related to this product:

   WHIRLPOOL AKR 948 IX INSTRUCTION FOR USE (424 ko)

Manual abstract: user guide WHIRLPOOL AKR 948 IXPROGRAM CHART

Detailed instructions for use are in the User's Guide.

[. . . ] Rökröret och rörklämmorna (15) som krävs för installationen levereras inte tillsammans med fläktkåpan, utan måste köpas separat. N INSTALLASJONSVEILEDNING Minimumsavstand til komfyrtopp: 50 cm (elektriske kokeplater), 75 cm (gass-, parafin- eller kullkomfyr). Følg nummereringen ved montering (1Ö2Ö3Ö. . . . . ). Apparatet må ikke tilkobles strømnettet før installasjonen er helt avsluttet. Avtrekksrøret og festebåndene (15) følger ikke med og må anskaffes separat. DK INSTALLATIONSVEJLEDNING Minimumafstand fra kogezoner: 50 cm (elkogezoner), 75 cm (gas-, olie- eller kulfyrede kogezoner). [. . . ] Carry out the electrical connections between the two parts. Fix the hood to the extraction unit with 10 screws. Using a pencil, draw the centre line on the wall up to the ceiling to facilitate installation operations. Attach the hole diagram to the wall: the vertical centre line printed on the hole diagram must match the centre line drawn on the wall, and the lower edge of the hole diagram must match the lower edge of the hood: remember that with installation completed the bottom of the hood must be at least 50 cm above the cooktop in case of electric cookers and 75 cm in case of gas or mixed cookers. Place the support bracket on the hole diagram so that it matches the dashed rectangle, mark the two external holes and drill, remove the hole diagram, insert 2 wall plugs and fix the hood support bracket with two 5x45 mm screws. Adjust the distance between the hood and the wall. From inside the hood, mark the holes for fixing the hood permanently. Drill on the marks (Ø 8 mm - see step 10). Fit the flue support bracket G to the wall and against the ceiling, use the support bracket as hole diagram (the small slot on the support must match the line drawn on the wall - step 4) and mark 2 holes with the pencil, drill the holes (Ø 8 mm), and finally insert 2 plugs. Fix the flue support bracket to the wall with two 5x45 mm screws. Fix the hood to the wall with two 5x45 mm screws (ABSOLUTELY NECESSARY). Connect an exhaust pipe (pipe and clamps are not supplied and must be bought separately) to the collar B located above the extraction motor unit. For extractor operation, connect the other end of the exhaust pipe to the home discharge device. For filter operation, fix the deflector F to the flue support bracket G with 2 screws and connect the other end of the exhaust pipe to the deflector collar F (if the collar is not already fitted it should be inserted on the deflector and secured with 1 screw). Once the steam and fumes have been filtered by the carbon filter (not provided, to be ordered separately) they are conveyed back to the kitchen through grid H. Apply the flues and fix them with 2 screws (20a) to the flue support G (20b). Slide the bottom section of the flue in the special seat above the hood to completely cover the extraction unit. Refit the grease filter/s and check for correct hood operation.  5019 318 33080 S N DK FIN GB 31833080. fm Page 12 Friday, June 6, 2003 3:45 PM AKR 948 1. Telescopic flue. PRODUCT SHEET CONTROL PANEL To clean the grease filter Wash the grease filter at least once a month. 1: pull the spring release handle (f) downwards, then remove the filter. [. . . ] After washing, dry the filter in the oven at 100° C for 10 minutes to reactivate it. The filter will retain its odour-absorbing capacity for three years, after which it must be replaced. Fig. Use a small screwdriver or any other suitable tool to prise off (m-Fig. Replace using 20 W max halogen bulbs only, making sure not to touch them with your hands. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL AKR 948 IX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL AKR 948 IX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag